Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. bras. cir. cardiovasc ; 35(3): 274-284, May-June 2020. tab, graf
Artigo em Inglês | LILACS, SES-SP | ID: biblio-1137258

RESUMO

Abstract Objective: To investigate the predictive value of preoperative neutrophil-lymphocyte ratio (NLR) for long-term major adverse cardiac and cerebrovascular events (MACCE), which have not yet been well described, in patients undergoing coronary artery bypass grafting (CABG). Methods: The records of 751 consecutive patients who underwent elective CABG between January 2008 and January 2010 were retrospectively enrolled and stratified according to quartiles of preoperative NLR. At 7.8-year follow-up, MACCE was considered as an endpoint. Results: Overall MACCE was 11.6% of all cases. Long-term myocardial infarction, percutaneous coronary intervention, stroke and cardiovascular mortality were found associated with the upper NLR quartile (P<0.001, P<0.001, P=0.005, P<0.001, respectively). In multivariate analysis, NLR on admission remained an independent predictor of long-term MACCE (OR 1.087, 95% CI 1.026-1.151; P=0.004), in all EuroSCORE risk groups (P<0.001; P<0.001; P=0.029). The receiver operating characteristic (ROC) curve analyses revealed an NLR cut-off value of 4.32 predicting MACCE. Conclusion: NLR is a useful and readily available predictive marker of long-term MACCE following CABG, independent of the EuroSCORE.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Linfócitos , Ponte de Artéria Coronária/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Neutrófilos
2.
Arq. bras. cardiol ; 107(4): 305-313, Oct. 2016. tab
Artigo em Inglês | LILACS | ID: biblio-827859

RESUMO

Abstract Background: Atrial fibrillation (AF) is the most common arrhythmia seen in adults. Atrial stunning is defined as the temporary mechanical dysfunction of the atrial appendage developing after AF has returned to sinus rhythm (SR). Objectives: We aimed to evaluate atrial contractile functions by strain and strain rate in patients with AF, following pharmacological and electrical cardioversion and to compare it with conventional methods. Methods: This study included 41 patients with persistent AF and 35 age-matched control cases with SR. All the AF patients included in the study had transthoracic and transesophageal echocardiography performed before and after. Septum (SEPsSR), left atrium (LAsSR) and right atrium peak systolic strain rate (RAsSR) were defined as the maximum negative value during atrial contraction and septum (SEPε), left atrium (LAε) and right atrium peak systolic strain (RAε) was defined as the percentage of change. Parameters of two groups were compared. Results: In the AF group, 1st hour and 24th hour LAε, RAε, SEPε, LAsSR, RAsSR, SEPsSR found to be significantly lower than in the control group (LAε: 2.61%±0.13, 3.06%±0.19 vs 6.45%±0.27, p<0.0001; RAε: 4.03%±0.38, 4.50%±0.47 vs 10.12%±0.64, p<0.0001; SEPε: 3.0%±0.22, 3.19%±0.15 vs 6.23%±0.49, p<0.0001; LAsSR: 0.61±0.04s-1, 0.75±0.04s- 1 vs 1.35±0.04s-1, p<0.0001; RAsSR: 1.13±0.06s-1, 1.23±0.07s-1 vs 2.10±0.08s- 1, p<0.0001; SEPsSR: 0.76±0.04s- 1, 0.78±0.04s- 1 vs 1.42±0.06 s- 1, p<0.0001). Conclusion: Atrial strain and strain rate parameters are superior to conventional echocardiographic parameters for the evaluation of atrial stunning in AF cases where SR has been achieved.


Resumo Fundamento: A fibrilação atrial (FA) é a arritmia mais comum em adultos. Define-se atordoamento atrial como a disfunção mecânica temporária do apêndice atrial que se desenvolve depois de reversão da FA ao ritmo sinusal (RS). Objetivos: Avaliar as funções atriais contráteis através de strain atrial e strain rate em pacientes com FA, após cardioversão farmacológica e elétrica, assim como compará-los com os métodos convencionais. Métodos: Este estudo incluiu 41 pacientes com FA persistente e 35 controles com RS e pareados por idade. Todos os pacientes com FA incluídos neste estudo foram submetidos a ecocardiografia transtorácica e transesofágica antes e após. Strain rates de pico sistólico do septo (SEPsSR), do átrio esquerdo (LAsSR) e do átrio direito (RAsSR) foram definidas como o máximo valor negativo durante contração atrial. Strains de pico sistólico do septo (SEPε), do átrio esquerdo (LAε) e do átrio direito (RAε) foram definidas como porcentagem de mudança. Resultados: No grupo com FA, os parâmetros LAε, RAε, SEPε, LAsSR, RAsSR e SEPsSR da 1a hora e da 24a hora foram significativamente mais baixos que no grupo controle (LAε: 2,61%±0,13; 3,06%±0,19 vs 6,45%±0,27; p<0,0001; RAε: 4,03%±0,38; 4,50%±0,47 vs 10,12%±0,64; p<0,0001; SEPε: 3,0%±0,22; 3,19%±0,15 vs 6,23%±0,49; p<0,0001; LAsSR: 0,61±0,04s-1; 0,75±0,04s-1 vs 1,35±0,04s-1; p<0,0001; RAsSR: 1,13±0,06s-1; 1,23±0,07s-1 vs 2,10±0,08s-1; p<0,0001; SEPsSR: 0,76±0,04s-1; 0,78±0,04s-1 vs 1,42±0,06 s-1; p<0,0001). Conclusão: Os parâmetros strain atrial e strain rate são superiores aos parâmetros ecocardiográficos convencionais para avaliar atordoamento atrial em pacientes com FA que reverteram ao RS.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Fibrilação Atrial/complicações , Fibrilação Atrial/fisiopatologia , Função Atrial/fisiologia , Miocárdio Atordoado/fisiopatologia , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Volume Sistólico/fisiologia , Sístole/fisiologia , Fatores de Tempo , Cardioversão Elétrica/métodos , Ecocardiografia , Reprodutibilidade dos Testes , Miocárdio Atordoado/diagnóstico por imagem , Estatísticas não Paramétricas , Apêndice Atrial/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA