Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Rev. bras. cir. plást ; 28(4): 570-576, july-sept. 2013.
Artigo em Inglês | LILACS | ID: lil-778830

RESUMO

The goal of aesthetic otoplasty is the correction of ear deformities by creating harmonious and symmetrical external ears, without visible scars. Otoplasty techniques based on the excision of postauricular skin are associated with high recurrence rates. Modern otoplasty is based on cartilage-cutting and cartilage-sparing techniques, alone or in combination, which lead to lower recurrence rates. Objective: We evaluated the efficacy of otoplasty combined with other techniques in the correction of ear deformities, based on a modified version of the "algorithm for otoplasty at the Craniofacial Center at Texas Children's Hospital". Methods: Forty patients, who underwent otoplasty for prominent ears in our institution between March and September of 2009, were prospectively assessed. The mastoid-helix distance was measured preoperatively (baseline) and at 1, 3, and 6 months postoperatively. Results: The most common deformities were scaphoconchal angle greater than 90° (51.3%, 41/80 ears) and conchal hypertrophy > 2.5 cm (46.3%, 37/80 ears). Recurrence occurred in 2 (5%) patients and partial stenosis of the ear canal in 1 (2.5%). Significant reductions in the mastoid-helix distance were observed at the three time points compared with baseline (P

O objetivo da otoplastia estética é a correção de deformidades da orelha, criando orelhas externas harmoniosas e simétricas. As técnicas de otoplastia, baseadas na excisão da pele pós-auricular, estão associados com a recorrência elevada. A otoplastia moderna é baseada nas técnicas de ressecção e/ou modelagem da cartilagem, que levam que menores taxas de recorrência. Objetivo: Foi avaliada a eficácia da otoplastia com técnica combinada na correção de deformidades da orelha, baseado numa versão modificada do "algoritmo para otoplastia", na Centro Craniofacial do Hospital Infantil do Texas". Método: Quarenta pacientes submetidos à otoplastia por orelhas proeminentes, entre março e setembro de 2009, foram avaliados prospectivamente. A distância mastoide-hélice foi medida no pré-operatório e após 1, 3 e 6 meses após a cirurgia. Resultados: As deformidades mais comuns foram ângulo escafo_concha I maior que 90° (51,3%, 41/80 orelhas) e hipertrofia de concha> 2,5cm (46,3%, 37/80 orelhas). Reduções significativas na distância mastoide_hélice foram observadas nos três períodos em comparação com os valores basais (P

Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto Jovem , Técnicas e Procedimentos Diagnósticos , Procedimentos Cirúrgicos Otológicos , Orelha Externa/anormalidades , Orelha Externa/cirurgia , Otopatias/cirurgia , Cuidados Pós-Operatórios , Estética , Métodos , Pacientes , Estudos Retrospectivos , Cirurgia Plástica , Terapêutica
2.
Rev. bras. cir. plást ; 25(2): 278-284, abr.-jun. 2010. ilus
Artigo em Português | LILACS | ID: lil-579330

RESUMO

Introdução: Para análise comparativa de fotografias é necessário haver padronização. Diferentemente de outras regiões do corpo, a região periorbital, por se constituir de uma anatomia extremamente dinâmica, torna a padronização um desafio. Existem nove parâmetros que, se não padronizados, podem influenciar a avaliação objetiva de fotografias da região periorbital. Entre estes parâmetros temos o plano facial coronal, plano da câmera fotográfica, posição do olhar, altura da câmera em relação ao paciente, uso do flash, mímica facial, distância do paciente à câmera fotográfica, distância focal da câmera fotográfica (zoom) e as condições de iluminação. Objetivo: O objetivo deste estudo é demonstrar que pequenas variações nos parâmetros citados anteriormente podem provocar alterações significativas nos elementos periorbitais. Método: Para manutenção dos nove parâmetros necessários à padronização foi utilizada uma lâmpada defenda oftalmológica adaptada. Doze pacientes foram fotografados em perfil frontal, utilizando a padronização, sendo observada a variação da fenda palpebral medida na linha médio pupilar, alterando-se o plano coronal, posição do olhar, uso do flash e variação da altura da câmera. Resultados: Com a variação dos parâmetros foi obtida alteração significativa da fenda palpebral vertical em todos os pacientes. Conclusão: As mudanças de posição utilizadas no trabalho são sutis e dificilmente percebidas quando tiramos foto livre sem fixar os planos e distâncias, falseando resultados na análise objetiva das fotografias quando não adequadamente padronizadas.


Introduction: For comparative analysis of photographs the standardization becomes necessary. Unlike other regions of the body, the periorbital region has an extremely dynamic anatomy, that makes standardization a challenge. There are nine parameters if not standardized can influence the objective evaluation of periorbital region photographs. These parameters are: the facial coronal plane, camera’s plane, the gaze position, camera height in relation to the patient, the use of flash, facial movements, distance of the patient to the camera, camera lens focal length (zoom) and lighting conditions. Objective: The objective of this study is to demonstrate that small variations in the parameters mentioned above can cause significant changes in the periorbital elements. Methods: To make the standardization an adapted ophthalmologic slit lamp was used. Twelve patients were photographed in front profile using the standardizationand observed the change of the palpebral fissure measured at mid pupillary line by changingthe coronal plane, gaze’s position, use of flash and height variation of the camera. Results: With the parameters changes we obtained statistically changes of vertical palpebral fissure in all patients. Conclusion: The changes in the position used at work are subtle and hardly noticed when we took pictures free no setting plans and distances, falsifying results in objective analysis of the photographs when not adequately standardized.


Assuntos
Humanos , Feminino , Adulto , Blefaroplastia , Fotografia/métodos , Órbita/cirurgia , Pálpebras/cirurgia , Procedimentos de Cirurgia Plástica , Métodos , Pacientes , Cirurgia Plástica , Métodos
3.
Acta cir. bras ; 25(2): 194-200, Mar.-Apr. 2010. graf, tab
Artigo em Inglês | LILACS | ID: lil-540496

RESUMO

Purpuse: To assess the accuracy of the variables stair climbing time (SCt), stair climbing power (SCP), six-minute walk test distance (6MWT), and forced expiratory volume in 1 second (FEV1) using maximal oxygen uptake on exercise (VO2max) as the gold standard. Methods: Tests were performed in 51 patients. FEV1 was measured by spirometry and 6MWT was performed in a flat 120-m corridor. Stair climbing test was performed on a 6-flight stairway to obtain SCt and SCP. VO2max was measured by ergospirometry, using the Balke protocol. Pearson's linear correlation and p values were calculated between VO2max and the other variables tested. For accuracy calculations, variable cutoff points were obtained through receiver operating characteristic (ROC) curves, dividing individuals into normal or unhealthy. Kappa statistic was used to calculate concordance. RESULTS: Accuracy was: SCt - 86 percent, 6MWT - 80 percent, SCP - 71 percent, FEV1(L) - 67 percent, FEV1( percent) - 63 percent. SCt and 6MWT showed 93.5 percent sensitivity when combined in parallel, and 96.4 percent specificity in series. Conclusion: SCt presented the best accuracy. SCt and 6MWT combined showed nearly 100 percent sensitivity or specificity. Thus, these simple exercise tests should be more routinely used, especially when an ergospirometer is not available to measure VO2max.


Objetivo: Determinar a acurácia das variáveis: tempo de escada (tTE), potência de escada (PTE), teste de caminhada (TC6) e volume expiratório forçado (VEF1) utilizando o consumo máximo de oxigênio (VO2máx) como padrão-ouro. Métodos: Os testes foram realizados em 51 pacientes. O VEF1 foi obtido através da espirometria. O TC6 foi realizado em corredor plano de 120m. O TE foi realizado em escada de 6 lances obtendo-se tTE e PTE. O VO2máx foi obtido por ergoespirometria, utilizando o protocolo de Balke. Foram calculados a correlação linear de Pearson (r) e os valores de p, entre VO2máx e variáveis. Para o cálculo da acurácia, foram obtidos os pontos de corte, através da curva característica operacional (ROC). A estatística Kappa (k) foi utilizada para cálculo da concordância. Resultados: Obteve-se as acurácias: tTE - 86 por cento, TC6 - 80 por cento, PTE - 71 por cento, VEF1(L) - 67 por cento, VEF1 por cento - 63 por cento. Para o tTE e TC6 combinados em paralelo, obteve-se sensibilidade de 93,5 por cento e em série, especificidade de 96,4 por cento. Conclusão: O tTE foi a variável que apresentou a melhor acurácia. Quando combinados o tTE e TC6 podem ter especificidade e sensibilidade próxima de 100 por cento. Estes testes deveriam ser mais usados rotineiramente, especialmente quando a ergoespirometria para a medida de VO2máx não é disponível.


Assuntos
Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Teste de Esforço/normas , Consumo de Oxigênio/fisiologia , Espirometria/normas , Caminhada/fisiologia , Teste de Esforço/métodos , Volume Expiratório Forçado , Valor Preditivo dos Testes , Cuidados Pré-Operatórios , Reprodutibilidade dos Testes , Espirometria/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA