Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Braz. dent. j ; 32(5): 87-95, Sept.-Oct. 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1350290

RESUMO

Abstract This study evaluated the effect of the use of glass ionomer cement (GIC) and flowable bulk-fill resin composite (BFRC) for filling pulp chambers and the type of high-speed handpiece light used on dentin removal during access preparation for endodontic retreatment in molar teeth. Twenty maxillary molars were treated endodontically. BFRC (Opus Bulk Fill Flow APS, FGM) was used to fill the pulp chamber and replace coronal dentin (n = 10). In the remaining teeth, the pulp chamber was filled with GIC (Maxion R, FGM). Conventional resin composite (Opallis, FGM) was used to restore the enamel layer in all teeth. The samples in each group were divided into two subgroups, and the root canals were reaccessed using a handpiece with white or ultraviolet light. The teeth were scanned using micro-CT before and after root canal reaccess. The dentin volume removed was calculated and analyzed using 2-way analysis of variance and Tukey's test (α = 0.05). The crown and pulp chamber locations with dentin removal are described using frequency distribution. During the access, fewer pulp chamber walls were affected and a lower volume of dentin was removed from the pulpal floor in the group restored with GIC than in the group restored with BFRC. No effect was observed on the coronal dentin walls with respect to the filling protocols and type of light used. For dentin removal from the pulp chamber, handpieces with white light performed better than those with ultraviolet light, irrespective of the filling protocol used. The use of GIC to fill the pulp chamber and use of white handpiece light reduced dentin removal from the pulpal floor and resulted in fewer affected dentin walls.


Resumo Este estudo avaliou os efeitos do cimento de ionômero de vidro (GIC) e da resina composta fluida bulk fill (BFRC) usados como preenchimento da câmara pulpar; e o tipo de iluminação das turbinas de alta rotação na remoção dentinária após cavidades de acesso para retratamento endodôntico em dentes molares. Vinte molares superiores foram tratados endodonticamente. Dez dentes foram restaurados usando BFRC (Opus Bulk Fill Flow APS, FGM) para preencher a câmara pulpar e dentina coronária; e resina composta convencional (Opallis, FGM) para restaurar a camada de esmalte. Os outros dentes foram restaurados usando GIC (Maxion R, FGM) para preencher a câmara pulpar e resina composta (Opallis, FGM). As amostras foram divididas em dois grupos e os canais radiculares foram novamente acessados com turbina de alta-rotação com iluminação branca ou ultravioleta. Os dentes foram escaneados usando micro-CT antes e após o novo acesso ao canal radicular. O volume de dentina removida foi calculado e os dados foram analisados por ANOVA bidirecional e teste de Tukey (α=0,05). As regiões na coroa e na câmara pulpar que apresentaram dentina removida no acesso dos canais foram descritas por meio de distribuição por frequência. A reabertura do canal radicular com GIC resultou em menos paredes afetadas da câmara pulpar e menor volume de dentina removida no assoalho. Nenhum efeito foi observado nas paredes de dentina coronária considerando aos protocolos de preenchimento. A turbina de alta rotação com iluminação branca reduziu a remoção de dentina da câmara pulpar, independentemente do protocolo de restauração utilizado. O uso de turbina de alta rotação com iluminação branca e GIC para preencher a câmara pulpar reduziram a remoção de dentina do assoalho e afetaram menos paredes dentinárias.

2.
Braz. dent. j ; 29(3): 282-289, May-June 2018. graf
Artigo em Inglês | LILACS | ID: biblio-951554

RESUMO

Abstract The combination of the restoration location, the hand preference of the operator using the light-curing unit (LCU), and the design of the LCU all can have an impact on the amount of the light delivered to the restoration. To evaluate the effect of left-handed or right-handed users, the position of the operator (dentist or assistant), and the LCU design on the irradiance, radiant exposure and emission spectrum delivered to the same posterior tooth. Two light emitting diode (LED) LCUs were tested: an angulated monowave LCU Radii-Cal (SDI, Victoria, Australia) and a straight aligned multi-peak LCU Valo Cordless (Ultradent, South Jordan, UT, USA). The irradiance values (mW/cm2), radiant exposure (J/cm2) and emission spectrum were measured using a sensor in maxillary left second molar tooth. The irradiance and radiant exposure were analyzed using three-way ANOVA followed by Tukey test (a=0.05). The emission spectra (nm) were analyzed descriptively. The interaction between LCU design, operator position, and hand preference significantly influenced the irradiance and radiant exposure (P<0.001). In all cases, Valo delivered significantly higher irradiance than Radii-Cal. The handedness and the operator position affected the irradiance and radiant exposure delivered from Valo. Operator position and access affect the irradiance and radiant exposure delivered to the maxillary left second molar. The irradiance and radiant exposure can be greater when a right-hand operator is positioned on the right side of the chair and a left-hand operator is positioned on the left side of the chair. This may result in better resin composite polymerization.


Resumo A combinação da localização da restauração, a preferência de mão do operador ao utilizar aparelhos fotopolimerizadores (AFP) com luz emitida por diodo (LED) e o formato do AFP podem afetar a quantidade de luz fornecida à restauração. O objetivo foi avaliar o efeito de operadores canhotos e destros, a posição do operador (dentista ou auxiliar), e o formato do AFP na irradiância, energia radiante e espectro de luz entregue ao mesmo dente posterior. Dois AFP foram testados: um com formato angulado, onda única Radii-Cal (SDI, Victoria, Australia) e um formato reto multi-pico Valo Cordless (Ultradent, South Jordan, UT, USA). Os valores de irradiância (mW/cm²), energia radiante (J/cm²) e espectro de luz foram medidos utilizando um sensor no segundo molar superior esquerdo. A irradiância e energia radiante foram analisados utilizando ANOVA 3 fatores seguido por teste de Tukey (a=0.05). O espectro de luz (nm) foi analisado de forma descritiva. A interação entre o formato do AFP, posição do operador e preferência de mão foram significativamente influentes na irradiância e energia radiante (P<0.001). Em todos os casos, Valo teve irradiância significativamente maior que Radii-Cal. A mão dominante e a posição do operador afetaram a irradiância e energia radiante com o Valo. Posição do operador e acesso afetou a irradiância e exposição radiante entregue ao segundo molar superior esquerdo. A irradiância e exposição radiante teve melhores resultados quando AFP foi utilizado com a mão direita pelo operador posicionado na cadeira do lado direito e mão esquerda do operador posicionado do lado esquerdo da cadeira. Estes resultados podem levar a uma melhor polimerização da resina composta.


Assuntos
Humanos , Exposição à Radiação , Assistentes de Odontologia , Lâmpadas de Polimerização Dentária , Lateralidade Funcional , Luz , Desenho de Equipamento
3.
J. appl. oral sci ; 26: e20180004, 2018. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-954510

RESUMO

Abstract Objective This study aimed to evaluate the effect of the cavity preparation and ceramic type on the stress distribution, tooth strain, fracture resistance and fracture mode of human molar teeth restored with onlays. Material and Methods Forty-eight molars were divided into four groups (n=12) with assorted combinations of two study factors: BL- conventional onlay preparation with boxes made from leucite ceramic (IPS-Empress CAD, Ivoclar Vivadent); NBL- conservative onlay preparation without boxes made from leucite ceramic; BD- conventional onlay preparation with boxes made from lithium disilicate glass ceramic (IPS e.max CAD, Ivoclar Vivadent); NBL- conservative onlay preparation with boxes made from lithium disilicate glass ceramic cuspal deformation (µS) was measured at 100 N and at maximum fracture load using strain gauge. Fracture resistance (N) was measured using a compression test, and the fracture mode was recorded. Finite element analysis was used to evaluate the stress distribution by modified von Mises stress criteria. The tooth strain and fracture resistance data were analyzed using the Tukey test and two-way ANOVA, and the fracture mode was analyzed by the chi-square test (α=0.05). Results The leucite ceramic resulted in higher tooth deformation at 100 N and lower tooth deformation at the maximum fracture load than the lithium disilicate ceramic (P<0.001). The lithium disilicate ceramic exhibited higher fracture resistance than the leucite ceramic (P<0.001). The conservative onlay resulted in higher fracture strength for lithium disilicate ceramic. Finite element analysis results showed the conventional cavity preparation resulted in higher stress concentration in the ceramic restoration and remaining tooth than the conservative onlay preparation. The conservative onlays exhibited increased fracture resistance, reduced stress concentration and more favorable fracture modes. Conclusion Molars restored with lithium disilicate CAD-CAM ceramic onlays exhibited higher fracture resistance than molars restored with leucite CAD-CAM ceramic onlays.


Assuntos
Humanos , Cerâmica/química , Desenho Assistido por Computador , Preparo da Cavidade Dentária/métodos , Porcelana Dentária/química , Silicatos de Alumínio/química , Restaurações Intracoronárias/métodos , Poliuretanos/química , Valores de Referência , Fraturas dos Dentes , Resinas Acrílicas/química , Teste de Materiais , Reprodutibilidade dos Testes , Análise de Variância , Estatísticas não Paramétricas , Resinas Compostas/química , Falha de Restauração Dentária , Análise de Elementos Finitos , Análise do Estresse Dentário , Módulo de Elasticidade , Dente Molar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA