Southeast Asian J Trop Med Public Health ; 2006 May; 37(3): 503-7
Artigo em Inglês | IMSEAR | ID: sea-35563

RESUMO

The objective of this study was to develop and optimize the combined methods of air sampling and real time polymerase chain reaction (real-time PCR) for quantifying aerosol Legionella spp. Primers and TaqMan hydrolysis probe based on 5S rRNA gene specific for Legionella spp were used to amplify a specific DNA product of 84 bp. The impinger air sampler plus T-100 sampling pump was used to collect aerosol Legionella and as low as 10 fg of Legionella DNA per reaction could detected. Preliminary studies demonstrated that the developed method could detect aerosol Legionella spp 1.5-185 organisms /500 l of air within 5 hours, in contrast to culture method, that required a minimum of 7-10 days.


Assuntos
Aerossóis , Poluentes Atmosféricos/isolamento & purificação , Legionella pneumophila/genética , Reação em Cadeia da Polimerase/métodos