Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Artigo em Inglês | IMSEAR | ID: sea-38228

RESUMO

OBJECTIVE: To determine factors influencing immediate and medium-term results of Pulmonary Balloon Valvuloplasty (PBV) for pulmonary valve stenosis. MATERIAL AND METHOD: Between 1995 and 2001, the authors carried out PBV in 25 consecutive patients. Two treatment outcomes including immediate and medium-term results were analyzed. The immediate results were classified into two groups based on the pulmonary systolic pressure gradient (PG) immediately after dilation: group 1 with a PG < or = 35 mmHg and group II with a PG > 35 mmHg. At medium-term follow-up of 6 to 60 months, echocardiographic evaluations were analyzed and divided into two groups: group A with a PG < or = 25 mmHg and group B with a PG > 25 mmHg. Demographic characteristics and hemodynamic parameters of immediate and medium-term results were compared and analyzed. RESULTS: Immediately after PBV the right ventricular systolic pressure (RVSP) decreased from 115.3 +/- 37.6 mmHg to 67.0 +/- 28.5 mmHg (p < 0.001). The pulmonary systolic pressure gradient decreased from 90.4 +/- 37.9 mmHg to 39.3 +/- 25.6 mmHg (p < 0.001). Nine of the 25 patients (group 11; 36%), with incomplete immediate relief of the obstruction, had more symptoms, a higher baseline PG, higher right atrial pressure, higher RVSP, and a higher systolic pressure ratio. Six of the 25 patients (group B; 24%), with suboptimal medium-term results, had a higher right ventricular voltage on the electrocardiogram, higher pre-dilation PG, and higher RVSP. CONCLUSION: Successful medium-term outcomes following pulmonary balloon valvuloplasty were achieved in 76% of the patients, with a greater success rate (91%) in patients with a lower right ventricular voltage electrocardiogram (R wave amplitude in V1) < or = 21 mm, a prevalvuloplasty systolic gradient < or = 90 mmHg, and right ventricular systolic pressure < or = 125 mmHg.


Assuntos
Adolescente , Pressão Sanguínea , Criança , Pré-Escolar , Eletrocardiografia , Feminino , Humanos , Lactente , Masculino , Estenose da Valva Pulmonar/fisiopatologia , Fatores de Tempo
2.
Artigo em Inglês | IMSEAR | ID: sea-42436

RESUMO

The authors report a pseudoaneurysm in a 2-year-old boy presenting with fever, increasing cyanosis and right upper lung shadowing on a chest radiograph at six weeks following modified Blalock-Taussig shunt surgery. Echocardiography and a CT scan of the chest revealed a large pseudoaneurysm originating from the right subclavian artery at the proximal insertion of modified Blalock-Taussig shunt. The patient underwent aneurysmal resection, Blalock-Taussig shunt removal, right subclavian artery ligation and the creation of a central shunt between the ascending aorta and main pulmonary artery. Unfortunately, the patient died 3 hours after the operation.


Assuntos
Falso Aneurisma/diagnóstico , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Pré-Escolar , Diagnóstico Diferencial , Humanos , Pneumopatias/diagnóstico , Masculino , Complicações Pós-Operatórias , Tetralogia de Fallot/cirurgia
3.
Artigo em Inglês | IMSEAR | ID: sea-39799

RESUMO

Isolated primary chylopericardium is a rare entity with an obscure etiology. The authors report a 10-week-old male infant presenting with tachypnea and enlarged cardiac silhouette. Echocardiography revealed a large pericardial effusion. A specific diagnosis of chylopericardium was made by pericardiocentesis and analysis of the fluid. Despite the pericardial tube drainage and medium-chain triglyceride diet, pericardial effusion reaccumulated. Ligation of the thoracic duct with the establishment of a pleuropericardial window was performed through a left thoracotomy. Follow-up echocardiograms have shown no reaccumulation of the pericardial fluid.


Assuntos
Humanos , Recém-Nascido , Masculino , Derrame Pericárdico/congênito
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA