Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. Assoc. Med. Bras. (1992, Impr.) ; 69(3): 392-397, Mar. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1422662

RESUMO

SUMMARY OBJECTIVE: This study aimed to evaluate the diagnostic efficiency of contrast-to-noise and signal-to-noise ratios created by the contrast medium in detecting lymph nodes. METHODS: In this study, 57 short-axis subcentimeter lymph nodes in 40 cardiac computed tomography patients with noncontrast- and contrast-enhanced phases were evaluated. The contrast-to-noise ratios and signal-to-noise ratios of noncontrast- and contrast-enhanced lymph node-mediastinal fat and aortic-mediastinal fat tissues were determined. In addition, lymph nodes in noncontrast- and contrast-enhanced series were evaluated subjectively. RESULTS: There was a significant difference in lymph node-mediastinal fat signal-to-noise values between the contrast and noncontrast phases (p=0.0002). In the contrast phase, aortic density values were found to be 322.04±18.51 HU, lymph node density values were 76.41±23.41 HU, and mediastinal adipose tissue density values were −65.73±22.96 HU. Aortic-mediastinal fat contrast-to-noise ratio value was 20.23±6.92 and the lymph node-mediastinal fat contrast-to-noise ratio value was 6.43±2.07. A significant and moderate correlation was observed between aortic-mediastinal fat and lymph node-mediastinal fat contrast-to-noise ratio values in the contrast phase (r=0.605; p<0.001). In the contrast-enhanced series, there was a significant increase in the subjective detection of lymph nodes (p=0.0001). CONCLUSION: In the detection of paratracheal lymph nodes, the contrast agent increases the detection of short-axis subcentimeter lymph nodes quantitatively and qualitatively. Contrast enhances and facilitates the detection of paratracheal lymph nodes.

2.
Rev. bras. cir. cardiovasc ; 35(1): 34-40, Jan.-Feb. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1092462

RESUMO

Abstract Objective: To evaluate the influence of Bentall procedure on left ventricular function and condition on long-term follow-up. Methods: Seventy-three consecutive patients who underwent an aortic root and ascending aorta replacement with composite valve button Bentall or flanged Bentall technique, from January 2007 to November 2018, were included in this retrospective study. Results: Postoperative left ventricular ejection fraction significantly increased (52.14±11.38 vs. 56.79±11.36; P=0.041), left ventricular end-systolic diameter significantly reduced (38.25±9.31 mm vs. 34.17±9.15 mm; P=0.027), left ventricular end-diastolic diameter significantly reduced (56.42±9.72 mm vs. 51.58±9.03 mm; P=0.01), and left atrial diameter significantly reduced (45.33±12.77 mm vs. 39.25±12.41 mm; P=0.01), compared to preoperative values. Our long-term survival results are comparable with previous studies in which survival rates in 5 years and 10 years were 83.5% and 69.8%, respectively. In comparing patients according to their New York Heart Association (NYHA) functional class, it was shown that their postoperative functional capacity was improved during the follow-up period (2.1±0.56 vs. 1.2±0.42; P=0.001). Conclusion: The Bentall procedure significantly improved the left ventricular systolic function and condition and decreased the left ventricular end-systolic and end-diastolic diameters and the left atrial diameter on long-term follow-up, based on the transthoracic echocardiography. Bentall procedure can be performed with acceptable mortality and morbidity rates on long-term follow-up.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Função Ventricular Esquerda , Valva Aórtica , Volume Sistólico , Estudos Retrospectivos , Seguimentos , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA