Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Southeast Asian J Trop Med Public Health ; 1988 Mar; 19(1): 101-8
Artigo em Inglês | IMSEAR | ID: sea-34288

RESUMO

Levels of antibody in sera of 78 patients with opisthorchiasis, 30 patients with other liver diseases, 10 patients with schistosomiasis and 30 healthy individuals were compared using three serodiagnostic tests, namely indirect haemagglutination (IHA), enzyme-linked immunosorbent assay (ELISA) and lectin immuno test (LIT). The geometric mean reciprocal titer in sera of opisthorchiasis patients was significantly higher than patients with other diseases, patients with schistosomiasis and healthy individuals (p less than 0.00001). After treatment with praziquantel, the antibody titers were decreased and became lowest 120 days after treatment. A statistically significant decrease from the pre-treatment sample was observed only at 120 days after infection and not earlier and only with ELISA (p = 0.03) and not with IHA and LIT (p greater than 0.05). Even with ELISA, significant decrease in antibody titer was apparent only when the pre-treatment sera had high enough antibody titer. ELISA was therefore better than the other two tests for the assessment of cure provided that the titer of pre-treatment sera was high.


Assuntos
Animais , Anticorpos Anti-Helmínticos/análise , Concanavalina A/diagnóstico , Ensaio de Imunoadsorção Enzimática , Testes de Hemaglutinação , Humanos , Hepatopatias/imunologia , Opistorquíase/diagnóstico , Opisthorchis/imunologia , Praziquantel/uso terapêutico , Esquistossomose Japônica/imunologia , Sensibilidade e Especificidade , Testes Sorológicos/métodos , Tailândia
2.
Southeast Asian J Trop Med Public Health ; 1982 Jun; 13(2): 174-80
Artigo em Inglês | IMSEAR | ID: sea-30961

RESUMO

Suitability of different strains of Plasmodium falciparum grown continuously in vitro was compared using the indirect haemagglutination (IHA) the indirect immunofluorescent (IFA) tests and ELISA. In the tests employing soluble antigens (IHA and ELISA), there was a significant higher mean log titer of the same sera tested against different strains. Ranking of the strains in term of sensitivity for the detection of malaria antibody in people in the endemic area were G-112 = SO = CC greater than SU greater than PS in the IHA test and G-112 = SO greater than CC greater than SU greater than PS in the ELISA. The difference in the mean log titers appear to relate neither to the geographical location not the isoenzyme markers tested. There was also an apparent correlation between the results of the IHA and the IFA test but not between these two tests and ELISA.


Assuntos
Ensaio de Imunoadsorção Enzimática , Epitopos/imunologia , Imunofluorescência , Testes de Hemaglutinação , Humanos , Malária/imunologia , Plasmodium falciparum/imunologia , Tailândia
3.
Southeast Asian J Trop Med Public Health ; 1981 Dec; 12(4): 518-24
Artigo em Inglês | IMSEAR | ID: sea-32167

RESUMO

A technique has been described for a simultaneous preparation of merozoites and concentrated schizonts. The merozoites were harvested after high speed centrifugation of either the supernatant of the low speed centrifugation of the Plasmodium culture or the portion floated in physiogel. The concentrated schizonts were prepared by physiogel floatation technique followed by differential centrifugation in 50% percoll. An average of 56% of parasitized red cells were obtained, of which 64% were schizonts. Concentration of trophozoites and schizonts was 9.5 fold.


Assuntos
Meios de Cultura , Métodos , Plasmodium falciparum/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA