Journal of Southern Medical University ; (12): 1063-1065, 2010.
Artigo em Chinês | WPRIM | ID: wpr-289993

RESUMO

<p><b>OBJECTIVE</b>To evaluate neointimal proliferation following placement of a new drug-eluting stent (BUMA) by optical coherence tomography (OCT).</p><p><b>METHODS</b>Twenty-two patients with coronary artery disease were randomized into BUMA group (n=15) and Endeavor group (n=7) and underwent OCT imaging after 9 months of stent implantation.</p><p><b>RESULTS</b>The neointima hyperplasia (NIH) thickness in BUMA group were significantly smaller than that in endeavor group (0.220-/+0.140 mm vs 0.269-/+0.207 mm, P<0.001), and the uncovered Struts were significantly lower in BUMA group than in Endeavor group (5.65% vs 6.56%, P<0.0001). The luminal late loss in BUMA group was also significantly lower (34.87-/+11.50 vs 40.82-/+18.53, P=0.025).</p><p><b>CONCLUSION</b>BUMA stent is safe and effective for treatment of coronary artery disease.</p>


Assuntos
Humanos , Angioplastia Coronária com Balão , Proliferação de Células , Doença da Artéria Coronariana , Patologia , Terapêutica , Vasos Coronários , Patologia , Stents Farmacológicos , Estudos Prospectivos , Tomografia de Coerência Óptica , Túnica Íntima , Patologia
2.
Chinese Journal of Cardiology ; (12): 585-589, 2009.
Artigo em Chinês | WPRIM | ID: wpr-236450

RESUMO

<p><b>OBJECTIVE</b>To evaluate the characteristic of late stent malposition after drug-eluting stent implantation by optical coherence tomography (OCT).</p><p><b>METHODS</b>The study comprised of 32 patients (target vessels: 51, total stents: 71) underwent drug eluting stent implantation one year ago [average (14.8 +/- 5.2) months]. OCT images of the stent were analyzed at interval of 0.5 mm. The stent malposition was detected, the thickness of intima and gap between the stent strut and vessel wall were measured.</p><p><b>RESULTS</b>Stent malposition was detected in 7 patients without clinical cardiac events, including positive remodeling (n = 4), overlapping stents (n = 1) and stent struts covered with thrombus (n = 2). Stent strut apposition with complete intima coverage was about 97.6%, stent struts malposition was 2.4% including half of struts located at the ostium of side branch. The intima coverage of stent struts is similar between the struts at the side branch and others [(0.06 +/- 0.05) mm vs. (0.05 +/- 0.03) mm, P > 0.05].</p><p><b>CONCLUSION</b>The causes of late stent malposition include the primary malposition after stent implantation, positive remodeling, overlapping stents and stent struts located at the ostium of side branch. Thinner intima coverage was also observed on the stent struts with malposition.</p>


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Stents Farmacológicos , Tomografia de Coerência Óptica , Falha de Tratamento