Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of China Pharmaceutical University ; (6): 541-546, 2021.
Artigo em Chinês | WPRIM | ID: wpr-904326

RESUMO

@#In order to evaluate the consistency of the release behavior between the self-made saxagliptin and metformin hydrochloride sustained-release tablets and the reference preparations in vitro, the similarity of the dissolution curves between the self-made preparations and the reference preparations in four dissolution mediums: HCl (pH 1.0), acetate buffer saline (pH 4.5), phosphate buffer saline (pH 6.8) and pure water, and the gel morphology and strength of the self-made preparations and the reference preparations in the HCl (pH 1.0) solution medium were compared.Results showed that in four dissolution mediums, the dissolution rates of saxagliptin in the self-made preparations and the reference preparations at 15 min were greater than 85%, and the ?2 similarity factors of metformin hydrochloride were 89, 83, 80, 86, all greater than 50, so the dissolution of the self-made preparations was consistent with those of the reference preparations.The volume expansion rate, water absorption rate and erosion rate were consistent with those of the reference preparations, and the gel strength of the self-made preparations was the same as that of the reference preparations.The in vitro release behaviors of the self-made preparations and the reference preparations are consistent, which provide a good guarantee for bioequivalence.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 617-620, 2018.
Artigo em Chinês | WPRIM | ID: wpr-708101

RESUMO

Objective To investigate the effect of optimizing nursing process in emergency PCI on the reduction of radiation received by interventional nurses.Methods A total of 100 cases of acute myocardial infarction patients who need emergency PCI in First Affiliated Hospital of University of South China were selected for the study,with the first 50 cases as the control group using conventional nursing process and the other 50 cases as the optimization group using the optimal nursing process in the test.Two radiation monitoring methods were used at the same time to measure,record and analyze the radiation dose to the intervention nurses in the two groups.Results The differences in radiation doses to nurses between the two groups were statistically significant in the single operation of intracoronary drug configuration,non-intracoronary drug configuration,intravenous injection,patient care,emergency material unpacking,and contrast agent replacement (Z =-5.171,-3.774,-7.208,-2.454,-4.516,-3.819,P < 0.05).There was no significant difference in radiation dose to nurses between the two groups in the subcutaneous injection of drugs and vomiting care of patients (P > 0.05).The difference in radiation doses to nurses between the two groups during the entire operation was statistically significant (Z =-6.105,P < 0.05).Conclusions The optimized nursing process helps to reduce the radiation received by interventional nurses in emergency PCI.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA