Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Int. j. odontostomatol. (Print) ; 17(2): 174-185, jun. 2023. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1440356

RESUMO

This in silico study aimed to evaluate the biomechanical behavior of a full-arch implant-supported prosthesis on titanium and zirconia monotype implants. A 3D mandible containing 1.0 mm thick cortical and cancellous bone was modeled. Four dental implants (3.3 x 10 mm) were inserted into the jaw model in each model. The implants consisted of Titanium (Ti-S group) and Zirconia Monotype/one-piece (Zr-S group). Fixed full-arch implant-supported prostheses were cemented onto the implant. The models were exported to the analysis software and divided into meshes composed of nodes and tetrahedral elements. All materials were considered isotropic, elastic, and homogeneous. Therefore, all contacts were considered bonded, the mandible model was fixed in all directions, applying a static structural axial load of 300 N on the bottom of the fossa of the left mola r teeth. Microstrain and von-Mises stress (MPa) were adopted as failure criteria. Comparable stress and strain values were shown in the peri-implant bone for both groups. However, the Ti-S group presented a lower stress value (1,155.8 MPa) than the Zr-S group (1,334.2 MPa). Regarding bone tissues, the Ti-S group presented 612 µε and the Zr-S group presented 254 µε. The highest strain peak was observed in bone tissues around the implant closer to the load for both groups. Evaluating monotype zirconia and titanium implants, it is suggested that the greater the rigidity of the implant, the greater the concentration of internal stre sses and the less dissipation to the surrounding tissues. Therefore, monotype ceramic implants composed of yttrium-stabilized tetragonal polycrystalline zirconia may be a viable alternative to titanium implants for full-arch prostheses.


El objetivo de este estudio in silico fue evaluar el comportamiento biomecánico de una prótesis implanto soportada de arcada completa sobre implantes monotipo de titanio y zirconia. Se modeló una mandíbula en 3D que contenía tejido óseo cortical y esponjoso de 1,0 mm de espesor. En cada modelo, se insertaron cuatro implantes dentales (3,3 x 10 mm) en el modelo de mandíbula. Los implantes consistieron en Monotipo de Titanio y Zirconia. Sobre el implante se cementaron prótesis implanto soportadas de arcada completa fija. Los modelos se exportaron al software de análisis y se dividieron en mallas compuestas por nodos y elementos tetraédricos. Todos los materiales se consideraron isotrópicos, elásticos y homogéneos. Por lo tanto, todos los contactos se consideraron cementados, el modelo mandibular se fijó en todas las direcciones, aplicando una carga vertical estructural estática de 300 N en el fondo de la fosa de los dientes molares izquierdos. Se seleccionaron la microesfuerzo y la tensión de Von-Mises (MPa) como criterios de falla. Se mostraron valores de tensión y deformación comparables en el hueso periimplantario para ambos grupos. Sin embargo, el grupo Ti-S presentó un valor de estrés menor (1.155,8 MPa) que el grupo Zr-S (1.334,2 MPa). En cuanto a los tejidos óseos, el grupo Ti-S presentó 612 µε y el grupo Zr-S presentó 254 µε. La mayor concentración de deformación en el tejido óseo se observó en los tejidos alrededor del implante más cerca de la carga para ambos grupos. Al evaluar los implantes monotípicos de zirconia y titanio, se sugiere que cuanto mayor sea la rigidez del implante, mayor será la concentración de tensiones internas y menor la disipación a los tejidos circundantes. Por lo tanto, los implantes cerámicos monotipo compuestos de zirconia policristalina tetragonal estabilizada con itrio pueden ser una alternativa viable a los implantes de titanio para prótesis de arcada completa.


Assuntos
Implantes Dentários , Materiais Dentários , Estresse Mecânico , Fenômenos Biomecânicos , Análise de Elementos Finitos , Mandíbula/diagnóstico por imagem
2.
Int. j. odontostomatol. (Print) ; 17(2): 142-154, jun. 2023. tab, ilus
Artigo em Inglês | LILACS | ID: biblio-1440352

RESUMO

The present study proposed to describe, through a literature review, the use of new therapeutic management which allows for offering a better quality of life to individuals affected by these pathologies. A bibliographic search was conducted in the main health databases PUBMED (www.pubmed.gov) and Scholar Google (www.scholar.google.com.br), in which studies published from 1987 to 2023 were collected. In the first stage, the list of retrieved articles was examined by reading the titles and abstracts. In the second stage, the studies were selected by reading the full contents. Two authors (JDMM and DAQ) performed stages 1 and 2. Experimental, clinical, case-control, randomized controlled, and laboratory cohort studies, case reports, systematic reviews, and literature reviews, which were developed in living individuals, were included. Therefore, articles that did not deal with the subject in question, letters to the editor, opinion articles, duplicated literature in databases, and literature that did not address the variables under study, we re excluded. Contemporary dentistry uses alternative treatments capable of improving the patient's condition since a cure is not always possible. Therefore, the possibility of improving the quality of life becomes an important point to be reached. Evidence-based healthcare has made great advances in recent decades, especially in the areas of orofacial pain, TMD, and occlusion, especially related to orthodontic, prosthetic, and restorative care.


En el presente estudio se propuso describir, a través de una revisión bibliográfica, el uso de nuevos manejos terapéuticos que permitan brindar una mejor calidad de vida a los individuos afectados por estas patologías. Se realizó una búsqueda bibliográfica en las principales bases de datos de salud PUBMED (www.pubmed.gov) y Scholar Google (www.scholar.google.com.br), en las que se recopilaron estudios publicados entre 1987 y 2023. En la primera etapa, se examinó la lista de artículos recuperados mediante la lectura de los títulos y resúmenes. En la segunda etapa, los estudios fueron seleccionados mediante la lectura del contenido completo. Dos autores (JDMM y DAQ) realizaron las etapas 1 y 2. Se incluyeron estudios de cohortes experimentales, clínicos, de casos y controles, controlados aleatorios y de laboratorio, informes de casos, revisiones sistemáticas y revisiones de la literatura, que se desarrollaron en individuos vivos. Por lo tanto, se excluyeron artículos que no trataran el tema en cuestión, cartas al editor, artículos de opinión, literatura duplicada en bases de datos y literatura que no abordara las variables en estudio. La odontología contemporánea utiliza tratamientos alternativos capaces de mejorar el estado del paciente, ya que no siempre es posible la curación. Por lo tanto, la posibilidad de mejorar la calidad de vida se convierte en un objetivo importante. La atención médica basada en la evidencia ha logrado grandes avances en las últimas décadas, especialmente en las áreas de dolor orofacial, TMD y oclusión, especialmente en relación con la atención de ortodoncia, prótesis y restauración.


Assuntos
Humanos , Dor Facial/terapia , Transtornos da Articulação Temporomandibular/terapia , Terapia por Acupuntura/métodos , Estimulação Elétrica Nervosa Transcutânea/métodos
3.
Braz. oral res ; 25(4): 357-361, July-Aug. 2011. tab
Artigo em Inglês | LILACS | ID: lil-595860

RESUMO

The purpose of this study was to evaluate the dimensional accuracy of different materials used in the confection of dies. Two stainless steel standard models were confected. One of the models, which was 2 mm larger than the other model, was used to provide a uniform relief for the two-step putty-wash impression technique. Thirty impressions were obtained using a polyvinyl siloxane impression material and randomly divided into three groups (n = 10) according to the type of casting material: type IV dental stone, commercially available epoxy resin (Tri-Epoxy), and industrial epoxy resin (Sikadur). After the setting/polymerization of the casting material, the dimensional stability was measured in terms of the height, diameter of the base and diameter of the top from the obtained dies and from the standard metal model using a profile projector. Results were analyzed by ANOVA and Dunnet test (α = 0.05). In the height values, no significant difference was observed between the groups, except for Sikadur casts, which showed lower mean values. The Tri-Epoxi group showed statistically lower mean base diameter values, compared with the other groups, and both epoxy resin groups showed statistically lower mean top diameter values, compared with that for the type IV dental stone group. We concluded that type IV gypsum and the commercially available epoxy resin showed similar behavior in most areas. The industrial epoxy resin did not show the same characteristics, although the diameter of the base obtained with it was similar to that obtained with type IV dental stone.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA