Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
International Journal of Cerebrovascular Diseases ; (12): 88-94, 2021.
Artigo em Chinês | WPRIM | ID: wpr-882373

RESUMO

Objective:To investigated the correlation between vascular remodeling pattern and perforator stroke after stenting in patients with symptomatic intracranial vertebrobasilar artery stenosis.Methods:Patients with symptomatic intracranial vertebrobasilar atherosclerotic stenosis underwent stenting and high resolution magnetic resonance imaging (HR-MRI) from January 2017 to August 2020 were enrolled retrospectively. The data of demography, vascular risk factors, plaque characteristics, operation process and postoperative complications were collected. The plaque characteristics were observed by HR-MRI, and the correlation between vascular remodeling pattern and perforator stroke after stenting was analyzed.Results:A total of 41 patients were enrolled in the analysis. Their age was 60.1±8.8 years (range, 49-77 years). There were 31 males (75.6%). Among them, 21 (51.2%) were positive remodeling, 20 (48.8%) were non-positive remodeling, and 5 (12.2%) had perforator stroke after procedure. The incidence of perforator stroke in the positive remodeling group was significantly higher than that in the non-positive remodeling group (23.8% vs. 0%; P=0.048). The positive remodeling rate of the perforator stroke group was significantly higher than that of the non-perforator stroke group (100.0% vs. 44.4%; P=0.048). Conclusions:Patients with intracranial vertebrobasilar atherosclerotic stenosis and positive vascular remodeling were more likely to have perforator stroke after stenting.

2.
China Medical Equipment ; (12): 21-24, 2017.
Artigo em Chinês | WPRIM | ID: wpr-621106

RESUMO

Objective:To compare the results of three kinds of glucometers and automatic biochemistry analyzer for the detection of blood glucose level of finger capillary and vein blood, and adopt linear regression to analyze their relationship.Methods: 204 patients with or without diabetes were enrolled in this study. Their finger capillary and vein blood were detected by three kinds of glucose meters and automatic biochemistry analyzer, respectively. And these data were analyzed by using linear regression and pair-t-test.Results: The comparative results revealed that the order of correlation between every glucose meters with automatic biochemistry analyzer was Accuchek higher than GT-1920 and GT-1920 higher than One Touch when the range of hematocrit (Hct) value was in 35.1%-51.6%. The correlation of Hct between every glucose meter and automatic biochemistry analyzer when the range of Hct was 25.0%-35.0% was significant higher than that when the range was 35.1%-51.6% (t=2.19,P<0.05). For finger capillary blood, the bias of One Touch was largest, while for vein blood, the bias of GT-1920 and One Touch were better. Besides, the detected results of blood glucose both of GT-1920 and One Touch were significantly higher than automatic biochemistry analyzer(t=2.34,P<0.05).Conclusion: There were better correlation between every glucose meter and automatic biochemistry analyzer, respectively, and the correlations between them can be effected by Hct. While there were still certainly difference between them.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA