Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Indian J Ophthalmol ; 2010 May; 58(3): 243-245
Artigo em Inglês | IMSEAR | ID: sea-136066

RESUMO

We report the prevalence and risk factors for glaucoma among aphakes and pseudophakes in 3850 subjects who participated in a population-based study in urban south India. The subjects underwent an ophthalmic examination including applanation tonometry, gonioscopy, optic disc evaluation and frequency doubling perimetry. Glaucoma was diagnosed using the International Society of Geographical and Epidemiological Ophthalmology (ISGEO) criteria. Thirty eight, 15 aphakes and 23 pseudophakes (0.99% of 3850 subjects) of the 406 persons who had undergone cataract surgery were diagnosed with glaucoma. Aphakes/pseudophakes were at higher risk of glaucoma as compared to the phakic population (Odds Ratio: 2.71, 95% CI: 1. 94, 3.38, p=0.001). On multivariate analysis, older age and higher intra ocular pressure were risk factors for glaucoma. Blindness attributable to glaucoma was detected in 20% of aphakic and 4.3% of pseudophakic eyes. Glaucoma was a significant cause of morbidity in those who had undergone cataract surgery in this urban population.


Assuntos
Catarata/complicações , Extração de Catarata , Glaucoma/complicações , Glaucoma/epidemiologia , Humanos , Índia/epidemiologia , Prevalência , Fatores de Risco
2.
Indian J Ophthalmol ; 2008 Nov-Dec; 56(6): 516-7
Artigo em Inglês | IMSEAR | ID: sea-71144

RESUMO

The aim of the study was to assess agreement between two commercially available applanation tonometers for the measurement of intraocular pressure (IOP). Forty subjects underwent IOP measurement on two accurately calibrated Goldmann type applanation tonometers (Zeiss AT 030 (GATZ) and Inami L-5110(GATI)). The order of examination was randomized and observers were masked to the IOP recorded. The mean of two consecutive readings, from a randomly selected eye for each subject, was used for analysis. Agreement was assessed using the Altman and Bland plot. The mean (SD) IOP readings on GATZ was 15.32 (+/-6.80) mm Hg and on GATI was 13.52 (+/-5.65) mm Hg (p< 0.001, 95% CI of the difference: -2.48 to -1.11). The 95% limits of agreement on the Altman and Bland plot were:-2.47 to 6.16 mm Hg). There was significant inter-instrument variability between the two accurately calibrated Goldmann type applanation tonometers studied.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA