Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Ann Card Anaesth ; 2015 Oct; 18(4): 599-602
Artigo em Inglês | IMSEAR | ID: sea-165277

RESUMO

The indication of pacemaker/AICD removal are numerous. Serious complication can occur during their removal, severe tricuspid regurgitation is one of the complication. The occurrence of PFO is not uncommon among adult population. Shunting across PFO in most circumstance is negligible, but in some necessitates closure due to hypoxemia. We report a case of 62 year old man, while undergoing AICD removal, had an emergency sternotomy for cardiac tamponade. Postoperatively, he experienced profound hypoxemia refractory to oxygen therapy. Transthoracic Echocardiogram was performed to rule out intracardiac shunts at an early stage, but it was difficult to obtain an good imaging windows poststernotomy. A small pulmonary emboli was noted on CTPA, but was not sufficient to account for the level of hypoxemia and did not resolve with anticoagulation. Transesophageal echocardiogram showed flail septal tricuspid valve with severe TR and bidirectional shunt through large PFO. Patient was posted for surgery, tricuspid valve was replaced and PFO surgically closed. Subsequently, patient recovered well ad was discharged to home. Cause of hypoxemia might be due to respiratory or cardiac dysfunction. But for hypoxemia refractory to oxygen therapy, transoesophageal echocardiogram should be always considered and performed early as an diagnostic tool in post cardiac surgical patients.

2.
Ann Card Anaesth ; 2013 Oct; 16(4): 259-267
Artigo em Inglês | IMSEAR | ID: sea-149665

RESUMO

Left ventricular assist devices (LVAD) are increasingly used for mechanical circulatory support of patients with severe heart failure, primarily as a bridge to heart transplantation. Transesophageal echocardiography (TEE) plays a major role in the clinical decision making during insertion of the devices and in the post‑operative management of these patients. The detection of structural and device‑related mechanical abnormalities is critical for optimal functioning of assist device. In this review article, we describe the usefulness of TEE for optimal perioperative management of patients presenting for HeartWare LVAD insertion.


Assuntos
Insuficiência da Valva Aórtica/fisiopatologia , Catéteres , Ecocardiografia Transesofagiana , Forame Oval Patente/fisiopatologia , Coração Auxiliar , Humanos , Insuficiência da Valva Tricúspide/fisiopatologia , Função Ventricular Direita
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA