1.
Chinese Journal of Ultrasonography ; (12): 390-393, 2012.
Artigo em Chinês | WPRIM | ID: wpr-425675

RESUMO

Objective To investigate the viability of virtual touch tissue quantification (VTQ)technique in the prediction of acute rejection in transplanted liver.Methods One hundred and eighteen patients enrolled in the study were categorized into four groups:normal control (n =31),cirrhosis ( n =29),transplanted liver with acute rejection (n =28),transplant liver without any complications (n =30).All the patients were confirmed by pathology or clinical results.The VTQ of right robe of liver was obtained by a ultrasound system with VTQ technique and the data was compared among the four groups.Results The VTQ was (1.10 ± 0.29)m/s,(1.33 ± 0.33) m/s,(1.81 ± 0.47) m/s and (2.12 ± 0.59) m/s in normal control,transplanted liver without any complications,transplanted liver with acute rejection and cirrhosis group,respectively.It was significantly different in all four groups (P<0.01).Patients with acute rejection were associated with the increase of the VTQ values (P<0.01).Using a cutoff of VTQ>1.36 m/s measured in the transplanted liver for prediction of acute rejection,the sensitivity and specificity were 82.1% and 68.2%.Conclusions VTQ technique may have some clinical value in evaluation the acute rejection in transplanted liver.

2.
Chinese Journal of Ultrasonography ; (12): 953-956, 2012.
Artigo em Chinês | WPRIM | ID: wpr-430007

RESUMO

Objective To compare the hemodynamics features of recurrent hepatocellular carcinoma between contrast-enhanced ultrasonography (CEUS) and contrast-enhanced MRI (CEMRI).Methods Forty three recurrent hepatocellular carcinoma lesions in 39 patients were evaluated by CEUS and CEMRI.All lesions were proved by operation or needle biopsy.The dynamic enhancement and washout process on CEUS and CEMRI were analyzed.Results On both two methods,all lesions showed hyperenhancement.Among which,30.2% (13/43) lesions showed hyperenhancement during arterial phase and no washout was found during portal venous phase,37.2 % (16/43) lesions hyperenhanced during arterial phase and washout during portal venous phase.During late phase,the enhancement of 60.5% (26/43) lesions decreased and 7.0% (3/43) lesions showed no washout on CEUS or CEMRI.The overall concordance ratio between two methods was 67.4% (29/43).Difference of hemodynamics features between CEUS and CEMRI was not statistically significant.Conclusions CEUS can accurately display the hemodynamic features of recurrent hepatocellular carcinoma,and enjoy high consistence with CEMRI.

3.
Chinese Journal of Ultrasonography ; (12): 21-24, 2010.
Artigo em Chinês | WPRIM | ID: wpr-391348

RESUMO

Objective To investigate enhancement appearance of hepatic focal nodular hyperplasia(FNH) at real-time gray-scale contrast enhanced ultrasonography(CEUS),and evaluate the value of CEUS in the diagnosis of FNH. Methods Thirty-four patients (36 lesions) with histologically proved FNH were examined by ultrasonography. Appearance on conventional ultrasonography and the enhancement pattern on CEUS were investigated. Results Thirty-six lesions were mostly hypoechoic.39% (14/36) of lesions had peripheral hypoechogenic circle. Color Doppler flow imaging showed a asteroid-like or spoke-and-wheel pattern in 65% (20/ 31) of lesions.Three enhancement patterns were observed in the early arterial phase: whole-enhancement pattern (28%, 10/36), gushing-spring enhancement pattern (44%, 16/36), and spoke-and-wheel enhancement pattern (28%,10/36).The frequency of central scar on CEUS was 17% (6/36), and detection rate of central scar by CEUS compared with pathology was 40% (6/15).Regarding one of the features (gushing-spring enhancement, spoke-and-wheel enhancement and scar) as standard of FNH, the coincidence of CEUS in this group was 78% (28/ 36) ,which was significantly higher than that of conventional ultrasonography 28% (10/36).Conclusions CEUS can be as a important method for diagnosing FNH.

4.
Chinese Journal of Ultrasonography ; (12): 773-775, 2010.
Artigo em Chinês | WPRIM | ID: wpr-387100

RESUMO

Objective To compare enhancement features of primary hepatocellular carcinoma(PHCC)and recurrent hepatocellular carcinoma(RHCC) on.contrast-enhanced ultrasonography(CEUS). Methods CEUS was performed in 56 patients with 70 RHCC and 83 patients with 93 PHCC. The enhancement features of these two groups of hepatocellular carcinoma were compared. The time used for the enhancement material to arrive the lesion(Ta ), that used for the lesion to become isoechoic(T1 ) and hypoechoic relative to the surrounding hepatic parenchyma(To) were analyzed. The echogenicity change between the lesion and the parenchyma was observed during arterial phase,portal phase and delayed phase. Results The time used for the lesion to become hypoechogenicity of RHCC and PHCC was (104.0 ± 51.8)s, (85.5 ± 43.0)srespectively,there was significant difference between the two groups( P = 0.010). There were 24 (34.3 % )cases of RHCC and 16 ( 17.2% ) cases of PHCC becoming isoechoic during portal phase,the former rate was significantly higher than the later one( P = 0. 012). Conclusions There is significant difference between PHCC and RHCC in the performance of CEUS,this is useful for the early diagnosis of RHCC.

5.
Chinese Journal of Ultrasonography ; (12): 46-48, 2009.
Artigo em Chinês | WPRIM | ID: wpr-396924

RESUMO

Objective To evaluate the value of contrast-enhanced ultrasonography(CEUS)in the diagnosis of hepatic artery complications after liver transplantation.Methods Thirty-seven patients suspected of hepatic artery complications were examined by CEUS.Contrast agent was SonoVue and low mechanical index harmonic CEUS was performed.Results CEUS helped significantly improve flow visualization in hepatic artery(100%).After contrast agent injection,mean contrast material arrival time was(16.1±5.5)s in hepatic artery and(19.3±4.6)s in portal vein.The diagnostic accuracy of hepatic artery thrombosis(HAT)was improved from 86%(30/35)to 100%(35/35)with CEUS.In the HAT group,contrast material arrival time in portal vein was(13.6±4.6)s,shorter to that in group without HAT(P<0.05).Hepatic artery pseudo-aneurysm was also showed in 2 patients with CEUS after liver transplantation.Conclusions CEUS is a useful technique in improving hepatic artery visualization,which contribute to diagnose hepatic artery complications after liver transplantation.

6.
Chinese Journal of Ultrasonography ; (12)2003.
Artigo em Chinês | WPRIM | ID: wpr-541956

RESUMO

Objective To compare enhancement features of hepatic tumors on SonoVue-enhanced real-time gray-scale ultrasonography and contrast-enhanced helical CT.Methods SonoVue-enhanced real-time gray-scale ultrasonography and contrast-enhanced helical CT were performed on 49 patients with 54 focal liver lesions,including 29 primary liver carcinomas,4 metastatic liver tumors,11 hepatic carvernous hemangiomas,7 focal nodular hyperplasias,2 focal fatty sparing,1 cirrhotic.Results Contrast-enhanced ultrasonography and helical CT showed consistent results in demonstrating hemodynamics of hepatic tumors.In the differentiating of malignant tumors and benign tumors,the sensitivity,specificity and accuracy of contrast-enhanced ultrasonography were(90.9)%(30/33),(90.5)%(19/21) and(90.7)%((49/54)),respectively.Those of contrast-enhanced CT were(90.9)%(30/33),(95.2)%(20/21) and(92.6)%((50/54)),respectively.Conclusions Both of the two imaging methods are valuable for differential diagnosis of liver tumors.

7.
Chinese Journal of Ultrasonography ; (12)2003.
Artigo em Chinês | WPRIM | ID: wpr-539940

RESUMO

Objective To investigate the diagnosis of hepatic tumors by contrast-enhanced color Doppler ultrasonography. Methods Thirty-two patients with known focal liver lesions(diameter 11-112 mm,mean 43 mm) were studied with color Doppler flow imaging(CDFI) before and after injection of 2.4 ml SonoVue at the concentration of 5 mg/ml. The pathological diagnosis included 13 benign lesions and 19 malignant ones. Analysis was performed on signal intensity of intratumoral vascularity,time of enhancement duration,resistant index and maximum velocity of intratumoral arterial blood flow. The data were compared between benign and malignant lesions. Results Before injection of SonoVue,intratumoral blood flow could be detected among 53.8 %(7/13) benign lesions and 78.9 %(15/19) malignant tumors. However these detection rates went up to 76.9 %(10/13) and 100%(19/19) respectively after administration of SonoVue. Significant difference between benign and malignant tumors was observed in time of enhancement duration. Furthermore RI showed significant difference between benign and malignant lesions.Diagnostic accuracy of hepatic tumors increased from 75.0 %( 24/32 ) to 90.6 %(29/32) after enhancement. Conclusions The clinical results showed the ability of contrast-enhanced CDFI in reflecting the blood supply of the hepatic tumors,demonstrating the high sensitivity and specificity of the technique,which could be of great value to the diagnosis of hepatic tumors.

8.
Chinese Journal of Ultrasonography ; (12)2003.
Artigo em Chinês | WPRIM | ID: wpr-539633

RESUMO

Objective To evaluate the value of real-time enhanced-ultrasonography (EUS) in the diagnosis of hepatic tumor. Methods Twenty-nine patients with 34 hepatic solid lesions were examined by real-time EUS,including 16 primary liver malignant tumors,4 metastatic liver tumors,5 focal nodular hyperplasias (FNH),and 9 hemangiomas. All the cases were confirmed by histopathology. The ultrasound unit (Esaote Megas) with real-time EUS technique was used. The contrast agent used was SonoVue (Bracco,Italy). Results After injection of SonoVue,all the lesions were variously enhanced on real-time ultrasonogram. A holistic inhomogeneous enhanced pattern with quick disappearing was mostly detected by real-time EUS in hepatic malignant tumors,a peripheral and centripetal enhanced pattern was mostly shown in hamangiomas,and a radial centrifugal enhanced pattern with homogeneity and quickly was observed in FNHs. If the lesions with enhancement in arterial phase and disappearing in portal phase after injection of SonoVue were regarded as a sign for malignant liver tumor,the sensitivity,specificity and accuracy in the diagnosis of liver cancer with real-time EUS were respectively 95%(19/20),100%(14/14) and 97% (33/34). Conclusions The dynamic enhanced fashions and various enhanced features in various hepatic tumors will be reflected by real time EUS,which improves the accuracy of ultrasonography in the diagnosis of liver tumors.