Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Medical Instrumentation ; (6): 323-327, 2009.
Artigo em Chinês | WPRIM | ID: wpr-329314

RESUMO

An instantaneous blood pressure measuring system at the wrist based on the volume-compensation method is developed, and the characteristics and accuracy of the system is evaluated. The radial artery at the wrist is used as the detecting object, and a pad-type cuff as well as a newly designed electro- pneumatic converter is used in the system. Also, the comparative experiments between the system and the invasive blood measuring device (direct method) indicated that, the results obtained from the two methods are well correlated not only in rest condition, but also in a stressful condition. Therefore, the system is capable of non-invasive measuring instantaneous blood pressure in the radial artery.


Assuntos
Humanos , Determinação da Pressão Arterial , Métodos , Desenho de Equipamento , Artéria Radial , Fisiologia
2.
Japanese Journal of Physical Fitness and Sports Medicine ; : 481-493, 2000.
Artigo em Japonês | WPRIM | ID: wpr-371924

RESUMO

Electromyographic muscle activities of the shoulder muscles during shoulder external rotation with reference to load magnitude were studied in 8 healthy male subjects without history of shoulder injuries. In addition, we discussed the relationship between rotator cuff muscles and superficial muscles. The subjects performed shoulder external rotation from 60°internal rotation to 45° external rotation at 20° of shoulder abduction and 20° of flexion. A Cybex dynamometer used to prescribe angle and velocity of the shoulder movement. At the same time, intramuscular wire electrodes were inserted into the supraspinous, infraspinous and teres minor muscles, and then surface electrodes were placed over the posterior deltoid and middle trapezius muscles. The load magnitude ranged 2-18 Nm and the angle velocity was set at 15 deg/sec. The rotator cuff muscles became significantly to be activated from 2 Nm (the supraspinous and infraspinous m.) and from 4-5 Nm (the teres minor m.) compared with the muscle activity during non-load. The superficial muscles became significantly to be activated from 4-7 Nm (the posterior deltoid m.) and from 3-6 Nm (the middle trapezius m.) compared with the muscle activity during non-load. Within the load range (18 Nm 46.8% MVC), %iEMG of the rotator cuff muscles was always larger than that of the superficial muscles. Therefore, we concluded that the contribution of the rotator cuff muscles was larger than that of the superficial muscles up to 3-4 Nm, and activities of the superficial muscles increased gradually from 3-4 Nm during shoulder external rotation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA