Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
J. appl. oral sci ; 31: e20230181, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1514415

RESUMO

Abstract The effectiveness of at-home dental bleaching treatments depends on the time that bleaching products are in contact with the teeth surface and, consequently, on the adequate use of associated custom acetate trays. Objective This randomized single-blinded trial aimed to analyze if the daily usage time of these products influences the patient's compliance behavior when submitted to monitored at-home dental bleaching. Secondary outcomes were color change and tooth sensitivity. Methodology Sixty-six volunteers were randomly distributed into three groups (n=22): patients were instructed to use the trays for 2 (G2), 4 (G4), and 8 (G8) hours daily. The daily dental bleaching compliance behavior was measured using a microsensor inserted into the trays. Subjective and objective color evaluation assessments were adopted at baseline (T0), one (T1), two (T2), and three weeks (T3) after the beginning of the bleaching treatment, as well as two weeks after the treatment (T4). Tooth sensitivity was analyzed using the VAS scale, ranging from T1 to T4. Results G2 showed a greater degree of cooperation than G8 and cooperation was inversely proportional to the recommended usage time. Significantly higher color change was observed in the upper arch for G8 when compared to G2 in subjective analysis, from T1 to T4. There were no statistical differences between the groups in objective analysis. Conclusion Shorter recommended usage time of the bleaching product may improve the patient's compliance with at-home dental bleaching treatments. However, increased daily usage time may promote better subjective color change. Bleaching sensitivity was more significant in the first week for a longer time of use.

2.
Braz. j. oral sci ; 19: e201715, jan.-dez. 2020. ilus
Artigo em Inglês | BBO, LILACS | ID: biblio-1116536

RESUMO

Aim: Little is known about the reparability of glass ionomer cements (GICs) after storage in acid environments. The aim of this study was to evaluate the solubility and repairability of GICs immersed in acid solutions and subjected to brushing. Methods: Thirty discs of each GIC (Vitremer, VitroFil LC, VitroFil, and Maxxion R) were divided into three immersion groups: distilled water, Coca-Cola, or hydrochloric acid (HCl), then subjected to brushing. The weight of discs was measured before and after the immersions to determine mass alteration. Each disc was repaired, by adding the same brand of GIC over its surface. After immersing the repaired specimens in same solutions, shear bond strengths using universal testing machine were measured. Two-way ANOVA and Tukey's test was used (α=0.05). Results: Resin-modified GICs degrade after HCl immersion followed by brushing (p<0.05), while self-cured GICs were negatively affected by all challenges (p<0.05). The challenges decreased the repair strength for VitroFil LC (p<0.05), which had higher repair shear bond strength than the other GICs (p<0.05), exhibiting most cohesive failures. Conclusion: Self-cured GICs degraded when immersed in all acid solutions with brushing while resin-modified GICs only degraded following HCl immersion with brushing. Despite exhibiting the best repair results, VitroFil LC was the only GIC that was influenced by all the acid challenges


Assuntos
Solubilidade , Propriedades de Superfície , Teste de Materiais , Resistência ao Cisalhamento , Cimentos de Ionômeros de Vidro
3.
Braz. j. oral sci ; 17: e18026, 2018. ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-906106

RESUMO

Aim: This study evaluated the interface between glass ionomer cement (GIC) and dentin using the conventional and atraumatic restorative treatment (ART) techniques for removal of decayed tissue. Materials and Methods: After preparation of the cavities by the conventional (Group I ­ GI) and ART (Group II ­ GII) techniques, the specimens were divided into 3 subgroups according to the GIC used (n=10). The conventional GIC KETAC FILL (3M/ESPE) was used in the groups GI-1 and GII-1, the conventional GIC VIDRION R (SS WHITE) in the groups GI-2 and GII-2, and the modified GIC FUJI II LC (GC Corporation) in the groups GI-3 and GII-3. For the microscopic analysis, the teeth were decalcified in a solution containing equal portions of 50% formic acid and 20% sodium citrate, dehydrated and submitted to paraffin baths. The samples were sectioned (6m in thickness), stained by the Brown and Brenn method, and evaluated in a light microscope. Results: The microscopic analysis revealed interaction between the material and dentin structure only with the FUJI II LC. In addition, the behavior was superior for the conventional technique in comparison to the ART technique. Conclusion: It was concluded that the technique used for carious dentin removal does not seem to be determinant for the bonding of ionomeric materials to the dental structure, except for the resin-modified GIC in which the formed hybrid layer was higher using the conventional technique


Assuntos
Humanos , Tratamento Dentário Restaurador sem Trauma , Cárie Dentária , Dentina , Cimentos de Ionômeros de Vidro
4.
Braz. dent. j ; 27(6): 727-733, Nov.-Dec. 2016. graf
Artigo em Inglês | LILACS | ID: biblio-828060

RESUMO

Abstract The aim of this study was to evaluate the effects of hydrofluoric acid (HF) concentration and previous heat treatment (PHT) on the surface morphology and micro-shear bond strength (mSBS) of a lithium disilicate glass ceramic (EMX) to resin cement. One hundred four EMX specimens were randomly assigned to two groups (n=52) according to the HF concentration: 5% and 10%. A new random distribution was made according to the PHTs (n=13): control (no PHT); previously heated HF (70 °C); previously heated EMX surface (85 °C); the combination of heated HF + heated EMX surface. The etching time was set at 20 s. All EMX blocks were silanated and received a thin layer of an unfilled resin. Five resin cement cylinders were made on each EMX surface using Tygon tubes as matrices, and then stored for 24 h at 37 °C. One random etched EMX sample from each group was analyzed using field-emission scanning electron microscopy (FE-SEM). The data were subjected to two-way ANOVA and multiple comparisons were performed using the Tukey post hoc test (a=0.05). For the control groups, 5% HF showed statistically lower mSBS values when compared to 10% HF (p<0.05). PHT increased the mSBS values for 5% HF, yielding statistically similar results to non-PHT 10% HF (p<0.05). FE-SEM images showed increased glassy matrix removal when PHT was applied to HF 5%, but not to the same degree as for 10% HF. PHT has the potential to improve the bond strength of 5% HF concentration on lithium disilicate glass ceramic.


Resumo O objetivo deste estudo foi avaliar os efeitos das concentrações de ácido fluorídrico (AF) e do prévio tratamento térmico (PTT) na morfologia da superfície e resistência de união ao microcisalhamento (mRUM) de uma cerâmica vítrea de dissilicato de lítio (EMX) ao cimento resinoso. Cento e quatro espécimes de EMX foram aleatoriamente distribuídos em dois grupos (n=52) de acordo com a concentração do AF: 5% e 10%. Os espécimes foram novamente distribuídos de forma aleatória de acordo com o PTT (n=13): controle (sem PTT); AF previamente aquecido (70 °C); superfície do EMX previamente aquecida (85 °C); combinação entre AF e EMX aquecidos. O tempo de condicionamento foi fixado em 20 s. Todos os espécimes de EMX foram silanizados e receberam a aplicação de uma fina camada de um adesivo sem carga. Cinco cilindros de cimento resinoso foram confeccionados usando tubos Tygon como matrizes e então armazenados por 24 h a 37 °C. Uma amostra condicionada de cada grupo foi aleatoriamente selecionada e analisada em um microscópio eletrônico de varredura em emissão de campo (MEVEC). Os dados foram submetidos ao teste ANOVA de dois fatores e múltiplas comparações foram feitas pelo teste de Tukey (a=0.05). Para os grupos controle, AF 5% mostrou valor de mRUM estatisticamente menor do que AF 10% (p<0.05). PTT aumentou os valores de mRUM para o AF 5%, proporcionando resultados estatisticamente similares ao grupo AF 10% controle (p<0.05). MEVEC mostrou um aumento na remoção da matriz vítrea quando o PTT foi aplicado ao grupo AF 5%, no entanto esse efeito não foi visto no grupo AF 10%. O PTT tem o potencial de melhorar a resistência de união do AF 5% na cerâmica vítrea reforçada por disilicato de lítio.


Assuntos
Cerâmica , Colagem Dentária , Porcelana Dentária/química , Temperatura Alta , Ácido Fluorídrico/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Cimentos de Resina
5.
Braz. dent. j ; 27(2): 153-159, Mar.-Apr. 2016. tab
Artigo em Inglês | LILACS | ID: lil-778329

RESUMO

Abstract The aim of the study was to evaluate the effect of erosive pH cycling with solutions that simulate dental erosion on Martens hardness (HMV) and elastic modulus (Eit) of dentin restored with fluoride-releasing adhesive systems. Twenty-seven bovine dentin slabs were restored with three adhesive systems: Adper Single Bond 2 total-etch adhesive system, One Up Bond F and Clearfil SE Protect fluoride-containing self-etching adhesive systems. The restorations were made with Filtek Z250. The HMV and Eit values at distances of 10, 30, 50 and 70 µm from the interface were evaluated using a dynamic ultra microhardness tester before and after immersion in deionized water, citric acid and hydrochloric acid (n=9). Data were submitted to repeated-measures ANOVA and Fisher's PLSD tests (=0.05). After erosive cycling, HMV values of dentin decreased in all groups. For dentin restored with Adper Single Bond 2, the lowest values were found closer to the hybrid layer, while for One Up Bond F and Clearfil SE Protect, the values remained unaltered at all distances. For dentin restored with fluoride-releasing adhesive systems, a decrease in Eit was found, but after 30 µm this difference was not significant. The acid substances were able to alter HMV and Eit of the underlying dentin. For fluoride-releasing adhesives, the greater the distance from bonded interface, the lower the Eit values. The fluoride in One Up Bond F and Clearfil SE Protect was able to protect the underlying dentin closer to the materials. In this way, the fluoride from adhesive systems could have some positive effect in the early stages of erosive lesions.


Resumo O objetivo deste estudo foi avaliar o efeito da ciclagem de pH erosiva com soluções que simulam a erosão dental, na dureza Martens (HMV) e módulo de elasticidade (Eit) da dentina restaurada com sistemas adesivos contendo fluoretos. Vinte e sete blocos de dentina foram restaurados com três sistemas adesivos: sistema adesivo de condicionamento total Adper Single Bond 2 e sistemas adesivos autocondicionantes contendo fluoreto One Up Bond F e Clearfil SE Protect. As restaurações foram realizadas com resina Filtek Z250. Os valores de HMV e Eit nas distâncias de 10, 30, 50 e 70µm da interface foram avaliadas em ultramicrodurômetro dinâmico antes e após a imersão em água deionizada, ácido cítrico e ácido clorídrico (n=9). Dados foram submetidos à ANOVA para medidas repetidas e Fisher PLSD (α=0,05). Após a ciclagem erosiva, os valores de HMV da dentina diminuíram em todos os grupos. Para a dentina restaurada com Adper Single Bond 2, os menores valores foram encontrados próximo a camada híbrida enquanto que, para os sistemas adesivos One Up Bond F e Clearfil SE Protect, os valores permaneceram inalterados em todas as distâncias. Para a dentina restaurada com os materiais que liberam fluoretos, uma redução nos valores de Eit foi encontrada, mas após 30µm essa diferença não foi mais significante. As substâncias ácidas foram capazes de alterar a HMV e o Eit da dentina subjacente. Para os adesivos que liberam fluoretos, quanto maior a distância da interface adesiva, menor os valores de Eit. O fluoreto presente no One Up Bond F e Clearfil SE Protect foi capaz de proteger a dentina subjacente próxima aos materiais. Dessa maneira, a presença do flúor em sistemas adesivos pode ter algum efeito positivo em estágios iniciais de lesões erosivas.


Assuntos
Animais , Bovinos , Adesivos , Dentina/química , Fluoretos/administração & dosagem , Elasticidade , Testes de Dureza , Concentração de Íons de Hidrogênio
6.
Braz. dent. sci ; 18(2): 121-127, 2015. ilus, tab
Artigo em Inglês | LILACS, BBO | ID: lil-766796

RESUMO

Diversas são as falhas relacionadas às restaurações de amálgama, sendo necessário o reparo ou a substituição. Objetivo: O objetivo deste relato de casos clínicos foi apresentar uma condição comumente encontrada no consultório odontológico: restaurações de amálgama rasas fraturadas aliadas ao desejo do paciente de restaurações estéticas. Caso clínico: Foram realizadas em duas pacientes sete trocas de restaurações de amálgama fraturadas, provavelmente devido à profundidade inadequada dos preparos cavitários. As substituições foram executadas por 3 operadores diferentes, utilizando-se um sistema autocondicionante “multi-mode” com a técnica de condicionamento seletivo do esmalte e uma resina composta nanoparticulada com boas propriedades mecânicas e polimento. Ao final, pode-se verificar resultados estéticos satisfatórios para todas as restaurações, porém com variação entre os operadores, salientando a importância do treinamento do profissional, assim como atender o desejo estético do paciente. Conclusão: Dessa forma, pode-se concluir que a forma de resistência e retenção dos preparos para amálgama foi a principal causa das falhas das restaurações neste estudo. Além do mais, na presença de restaurações de amálgama com falhas, estas devem ser reparadas ou substituídas criteriosamente para evitar prejuízo ao remanescente dental; sendo a resina composta o material de eleição para substituição, por ser mais conservador e estético.


Several failures have been related in amalgam restorations that require repair or replacement. Objective: The aim of this case report was to demonstrate a usual clinical condition found in the dental office: fractured in amalgam restorations associated with the esthetic patient desire. Case report: Seven fractured amalgam restoration replacements, probably due to improper cavity design, were performed in two patients. Three different operators accomplished the replacements. It was applied a “multi-mode” adhesive system using the selective enamel etching technique and a nanofilled resin composite with good mechanical proprieties and polishing. At the end, satisfactory esthetic results were achieved for all restorations. However, differences among operators were detected, stressing the importance of professional training and esthetic desire. Conclusion: Thus, it was concluded that the resistance and retention form of amalgam design was the major concern on the failed amalgam restorations in this study. In addition, amalgam restorations must be replaced carefully to prevent damage the dental remaining, and the resin composite has been selected as a preferred option for amalgam replacement, since it is more conservative and esthetic.


Assuntos
Humanos , Feminino , Adulto Jovem , Condicionamento Ácido do Dente , Resinas Compostas , Amálgama Dentário , Falha de Restauração Dentária , Adesivos Dentinários
7.
Braz. j. oral sci ; 13(3): 187-192, Jul-Sep/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-725354

RESUMO

AIM: This study evaluated saliva effects on enamel morphology surface after microabrasion technique. METHODS: Enamel blocks (16 mm2) obtained from bovine incisors were divided into 9 groups as follows: one control group (no treatment), four groups with microabrasion treatment using 35% phosphoric acid and pumice (H3PO4+Pum) and other four groups treated with 6.6% hydrochloric acid and silica (HCl+Sil). One group of each treatment was submitted to 4 frames of saliva exposure: without exposure, 1-h exposure, 24-h exposure, and 7-days exposure on in situ regimen. Nineteen volunteers (n=19), considered as statistical blocks, used an intraoral appliance containing the specimens, for 7 days. Enamel roughness (Ra) was tested before and after treatment, and after saliva exposure. Confocal laser scanning microscopy (CLSM) was used to evaluate qualitatively the enamel morphology. RESULTS: All groups exhibited increased Ra after microabrasion. With regards to saliva exposure, the treatment with HCl+Sil presented more susceptibility to the saliva action, but no period of time was efficient in re-establishing this characteristic compared with the control group. CLSM analysis showed reduction of the micro-abrasive damages during the experimental times. CONCLUSIONS: Seven days of saliva exposure were not sufficient for the treated enamel to reach its normal characteristics compared with the control group...


Assuntos
Humanos , Masculino , Feminino , Esmalte Dentário , Microabrasão do Esmalte , Saliva
8.
J. appl. oral sci ; 22(4): 347-354, Jul-Aug/2014. graf
Artigo em Inglês | LILACS, BBO | ID: lil-718292

RESUMO

Superficial irregularities and certain intrinsic stains on the dental enamel surfaces can be resolved by enamel microabrasion, however, treatment for such defects need to be confined to the outermost regions of the enamel surface. Dental bleaching and resin-based composite repair are also often useful for certain situations for tooth color corrections. This article presented and discussed the indications and limitations of enamel microabrasion treatment. Three case reports treated by enamel microabrasion were also presented after 11, 20 and 23 years of follow-ups.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto Jovem , Microabrasão do Esmalte/métodos , Clareamento Dental/métodos , Descoloração de Dente/terapia , Resinas Compostas/uso terapêutico , Esmalte Dentário/efeitos dos fármacos , Seguimentos , Propriedades de Superfície , Fatores de Tempo , Resultado do Tratamento
9.
Artigo em Inglês | IMSEAR | ID: sea-154523

RESUMO

Context: The possibility of bleaching vital teeth with peroxide-based products considerably revolutionized esthetic dentistry. Aim: The aim of this clinical study was to evaluate tooth color change and dental sensitivity after exposure to preloaded film containing a 10% hydrogen peroxide whitening system (Opalescence Trθswhite Supreme). Materials and Methods: A total of 13 volunteers, aged 18 to 25 years, participated in this study. The patients used the whitening system once a day for 60 minutes during the 8-day study. For maxillary incisors and canines, the color change was visually evaluated with the Vita color scale before, immediately, and six months after the treatment. Tooth sensitivity was evaluated during the daily gel applications. All whitening applications were done in office and under the supervision of a dental professional. Statistical Analysis Used: The results were analyzed using the Friedman Test (nonparametric repeated measures ANOVA) at a level of 5%, and Dunn's Multiple Comparison Test at the level of 5%. Results: It was verified that the original mean color values observed at the baseline analysis differed significantly from those observed immediately after bleaching, as well as from those seen in the analysis at six months ( P = 0.001). There was no significant difference between the mean color values observed in the immediate time and in the analysis at six months ( P = 0.474). No tooth sensitivity was observed in any patients. Conclusion: It was concluded that the bleaching technique using the 10% hydrogen peroxide system was effective in a short period of time without tooth sensitivity during applications.


Assuntos
Adolescente , Adulto , Ensaios Clínicos como Assunto , Sensibilidade da Dentina/etiologia , Humanos , Peróxido de Hidrogênio , Clareamento Dental/métodos , Clareadores Dentários/administração & dosagem
10.
Acta odontol. latinoam ; 22(3): 177-181, 2009. tab, ilus
Artigo em Inglês | LILACS | ID: lil-585592

RESUMO

The objective of this study was to measure the thickness of the hybrid layer (HLT), length of resin tags (RTL) and bond strength (BS) in the same teeth, using a self-etching adhesive system Adper Prompt L Pop to intact dentin and to analyze the correlationbetween HLT and RTL and their BS. Ten human molars were used for the restorative procedures and each restored tooth was sectioned in mesio-distal direction. One section was submitted to light microscopy analysis of HLT and RTL (400×). Another section was prepared and submitted to the microtensile bond test (0.5 mm/min). The fractured surfaces were analyzed using scanning electron microscopy to determine the failure pattern. Correlationbetween HLT and RTL with the BS data was analyzed by linear regression. The mean values of HLT, RTL and BS were3.36 μm, 12.97 μm and 14.10 MPa, respectively. No significant relationship between BS and HLT (R2= 0.011, p>0.05) and between BS and RTL (R2= 0.038) was observed. The results suggested that there was no significant correlation between the HLT and RTL with the BS of the self-etching adhesive to dentin.


O objetivo dessa pesquisa foi mensurar a espessura da camada híbrida de adesão (CH), o comprimento dos prolongamentos resinosos (Tags) e a resistência de união (RU) em um mesmoespécime e analisar a correlação entre esses fatores, usando o adesivo autocondicionante Adper Prompt L Pop em dentina hígida. Dez molares humanos foram utilizados e após a realização dos procedimentos restauradores, de acordo com osfabricantes, cada espécime foi cortado ao meio no sentido mésio/distal. Em uma hemi-secção dental os espécimes foram descalcificados para análise e mensuração dos tags e da camadahíbrida de adesão em microscopia óptica comum (AXIOPHOT, 400X). Na outra hemi-secção, foi realizado o testede microtração em uma velocidade de 0,5 mm/min até sua ruptura. A superfície fraturada foi mensurada e classificada de acordo com o tipo de fratura observada em microscopia eletrônica de varredura. Os valores obtidos para os fatores em análise, correspondentes a cada espécime foram submetidos a um teste de correlação. As médias correspondentes a CH, Tagse RU foram 3,36μm, 12,97 μm 14,10 MPa, respectivamente. Não foi observado correlação entre a CH e RU (R2= 0,011, p>0,05) e entre os Tags e RU (R2= 0,038). Diante dos resultados,observamos não haver correlação entre a camada híbrida e a resistência à tração, assim como entre os tags e a resistência à tração do sistema adesivo autocondicionante empregado.


Assuntos
Adesivos Dentinários/métodos , Condicionamento Ácido do Dente/métodos , Resinas Compostas/química , Força Compressiva , Dentina , Microscopia/métodos , Interpretação Estatística de Dados
11.
J. appl. oral sci ; 17(spe): 19-26, 2009. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-576873

RESUMO

The presence of porosities at the dentin/adhesive interface has been observed with the use of new generation dentin bonding systems. These porosities tend to contradict the concept that etching and hybridization processes occur equally and simultaneously. Therefore, the aim of this study was to evaluate the micromechanical behavior of the hybrid layer (HL) with voids based on a self-etching adhesive system using 3-D finite element (FE) analysis. MATERIAL AND METHODS: Three FE models (Mr) were built: Mr, dentin specimen (41x41x82 μm) with a regular and perfect (i.e. pore-free) HL based on a self-etching adhesive system, restored with composite resin; Mp, similar to M, but containing 25 percent (v/v) voids in the HL; Mpp, similar to Mr, but containing 50 percent (v/v) voids in the HL. A tensile load (0.03N) was applied on top of the composite resin. The stress field was obtained by using Ansys Workbench 10.0. The nodes of the base of the specimen were constrained in the x, y and z axes. The maximum principal stress (σmax) was obtained for all structures at the dentin/adhesive interface. RESULTS: The Mpp showed the highest peak of σmax in the HL (32.2 MPa), followed by Mp (30 MPa) and Mr (28.4 MPa). The stress concentration in the peritubular dentin was high in all models (120 MPa). All other structures positioned far from voids showed similar increase of stress. CONCLUSION: Voids incorporated into the HL raised the σmax in this region by 13.5 percent. This behavior might be responsible for lower bond strengths of self-etching and single-bottle adhesives, as reported in the literature.


Assuntos
Humanos , Resinas Compostas/química , Corrosão Dentária , Colagem Dentária/métodos , Adesivos Dentinários/química , Dentina/química , Análise do Estresse Dentário , Dentina/ultraestrutura , Análise de Elementos Finitos , Teste de Materiais , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração
12.
RFO UPF ; 13(1): 25-29, jan.-abr. 2008. tab
Artigo em Português | LILACS, BBO | ID: lil-487405

RESUMO

Em muitos países, inclusive no Brasil, a odontologia tem dificuldades em se estabelecer em razão da falta de recursos financeiros para a aquisição de equipamentos. Buscando solucionar esse problema, foi desenvolvido um tratamento simplificado, denominado "tratamento restaurador atraumático" (ART). O objetivo deste artigo é, por meio de uma revisão sistemática de literatura, expor e discutir os principais aspectos atuais relacionados com esse método. Foi realizado um levantamento bibliográfico nas principais bases de dados disponíveis (BBO, Lilacs e Medline), selecionando-se trabalhos publicados entre 1991 e 2005. Os temas considerados na seleção dos artigos científicos foram tipos de materiais preconizados, tempo de acompanhamento clínico, abrangência social e comparação entre as técnicas convencionais e ART. Foi observado que o ART não atende às necessidades restauradoras de todos os tipos de cavidades. Noas estudos analisados, o tempo de avaliação clínica varia de seis meses a três anos e, com relação ao material empregado na técnica, os cimentos ionômero de vidro (CIVs) alcançaram bons resultados. Os achados de algumas dessas pesquisas revelam índices de sucesso semelhantes quando comparados o ART e restaurações convencionais de amálgama. Conclui-se que o ART é uma alternativa viável e eficaz, principalmente para proporcionar assistência odontológica aos grupos populacionais mais necessitados. Mais pesquisas clínicas, laboratoriais, comportamentais e econômicas devem ser realizadas, buscando o aprimoramento do método.


Assuntos
Assistência Odontológica , Cárie Dentária , Saúde Bucal , Restauração Dentária Permanente/métodos
13.
J. appl. oral sci ; 15(4): 321-326, July-Aug. 2007. ilus, tab, graf
Artigo em Inglês | LILACS | ID: lil-463686

RESUMO

The bond strength of composite resins (CRs) to dentin is influenced by the interfacial microstructure of the hybrid layer (HL) and the resin tags (TAG). The contemporary self-etching primer adhesive systems overcame the inconvenient of the etch-and-rinse protocol. Studies, however, have demonstrated that HL thickness and TAG length vary according to the wetting time and additional use of acid-etching prior to self-etching primers. This study investigated the localized stress distribution in the HL and the dentin/adhesive interface. Two HL thicknesses (3 or 6 mum), two TAG lengths (13 or 17 mum) and two loading conditions (perpendicular and oblique-25°) were investigated by the finite element (FE) analysis. Five two-dimensional FE models (M) of a dentin specimen restored with CR (38 x 64 mum) were constructed: M1 - no HL and no TAG; M2 - 3 mum of HL and 13 ìm of TAG; M3 - 3 mum of HL and 17 mum of TAG; M4 - 6 mum of HL and 13 mum of TAG; and M5 - 6 mum of HL and 17 mum of TAG. Two distributed loadings (L) (20N) were applied on CR surface: L1 - perpendicular, and L2 - oblique (25°). Fixed interfacial conditions were assigned on the border of the dentin specimen. Ansys 10.0 (Ansys®, Houston, PA, USA) software was used to calculate the stress fields. The peak of von Mises (sigmavM) and maximum principal stress (sigmamax) was higher in L2 than in L1. Microstructures (HL and TAG) had no effect on local stresses for L1. Decreasing HL decreased sigmavM and sigmamax in all structures for L2, but the TAG length had influence only on the peributular dentin. The thickness of HL had more influence on the sigmavM and sigmamax than TAG length. The peritubular dentin and its adjacent structures showed the highest sigmavM and sigmamax, mainly in the oblique loading.

14.
J. appl. oral sci ; 14(1): 27-32, Jan.-Feb. 2006. ilus, tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-873183

RESUMO

Avaliação fotográfica para observar a presença ou a ausência de bolhas nos selantes de fóssula e fissuras Concise e Prisma Shield aos 7 dias, 18 meses, 36 meses e 11 anos, após a realização dos selamentos. METODOLOGIA: Foi aplicado na superfície oclusal, em todos os períodos de análise, uma solução corante a base de hematoxilina, que possibilitou a verificação e a avaliação dos materiais seladores presentes nesta superfície. Todas as superfícies oclusais foram fotografadas e as fotografias, correspondentes a cada período em análise, foram submetidas à avaliação fotográfica. RESULTADOS: Verificou-se diferença estatisticamente significativa somente aos 18 meses de análise, com o selante Prisma Shield apresentando um número significativamente maior de bolhas superficiais, que o selante Concise; enquanto que os demais grupos apresentaram-se estatisticamente semelhantes entre si, em todos os outros períodos de análise. Por outro lado, quando os selantes foram analisados isoladamente, nos períodos subseqüentes, não foi observada a presença de diferença estatisticamente significativa. CONCLUSÃO: De acordo com os resultados observados, pudemos verificar que os materiais seladores apresentaram o aparecimento e o desaparecimento de bolhas, fato que não interferiu na finalidade clínica do selamento realizado


Assuntos
Humanos , Adolescente , Fotografia Dentária , Selantes de Fossas e Fissuras , Cárie Dentária , Materiais Dentários
15.
J. appl. oral sci ; 14(1): 10-15, Jan.-Feb. 2006. tab
Artigo em Inglês | LILACS, BBO | ID: biblio-873186

RESUMO

INTRODUÇÃO: A evolução dos aparelhos fotopolimerizadores pode ser notada nos diferentes sistemas introduzidos recentemente no mercado. A tecnologia apresentada pelos aparelhos LED promete maior tempo de vida útil, não gerar aquecimento e produzir luz específica para a ativação da canforoquinona. No entanto, ainda são necessários estudos complementares para se conhecer a real efetividade destes aparelhos na polimerização dos materiais.PROPOSTA: Neste trabalho foi verificada a microdureza de 4 cores (B-0,5, B-1, B-2 e B-3) da resina composta Filtek Z-250 (3M ESPE) quando polimerizadas com 4 fontes de luz, sendo uma halógena (Ultralux - Dabi Atlante) e três LED (Ultraled - Dabi Atlante, Ultrablue - DMC e Elipar Freelight û 3M ESPE).MÉTODOS: Os 192 corpos-de-prova foram distribuídos em 16 grupos e os materiais foram inseridos em único incremento em matrizes cilíndricas de 4mm X 4mm, sendo polimerizados pelo tempo preconizado pelo fabricante. Em seguida, foram submetidos ao teste de microdureza na superfície superior e inferior dos cilindros. RESULTADOS: Os valores de dureza obtidos foram submetidos à análise de variância e ao teste de Tukey ao nível de 5%. Foi observado que a dureza dos corpos-de-prova variou conforme a cor do material e aparelhos utilizados. O aparelho LED que emite maior intensidade luminosa proporcionou a obtenção dos maiores valores de dureza, com o croma B-0,5 possibilitando a melhor polimerização. Por outro lado aparelhos com baixa intensidade luminosa foram os menos efetivos. Também foi observado que a região do fundo dos corpos-de-prova foi mais sensível à mudança das cores. CONCLUSÕES: A intensidade de luz dos fotopolimerizadores LED é fundamental para seu bom funcionamento, principalmente quando empregadas resinas com croma mais acentuado


Assuntos
Resinas Compostas , Instrumentos Odontológicos , Luz , Materiais Dentários , Dureza
16.
J. appl. oral sci ; 14(1): 10-15, Jan.-Feb. 2006. tab
Artigo em Inglês | LILACS, BBO | ID: lil-423352

RESUMO

INTRODUÇÃO: A evolução dos aparelhos fotopolimerizadores pode ser notada nos diferentes sistemas introduzidos recentemente no mercado. A tecnologia apresentada pelos aparelhos LED promete maior tempo de vida útil, não gerar aquecimento e produzir luz específica para a ativação da canforoquinona. No entanto, ainda são necessários estudos complementares para se conhecer a real efetividade destes aparelhos na polimerização dos materiais.PROPOSTA: Neste trabalho foi verificada a microdureza de 4 cores (B-0,5, B-1, B-2 e B-3) da resina composta Filtek Z-250 (3M ESPE) quando polimerizadas com 4 fontes de luz, sendo uma halógena (Ultralux - Dabi Atlante) e três LED (Ultraled - Dabi Atlante, Ultrablue - DMC e Elipar Freelight – 3M ESPE).MÉTODOS: Os 192 corpos-de-prova foram distribuídos em 16 grupos e os materiais foram inseridos em único incremento em matrizes cilíndricas de 4mm X 4mm, sendo polimerizados pelo tempo preconizado pelo fabricante. Em seguida, foram submetidos ao teste de microdureza na superfície superior e inferior dos cilindros. RESULTADOS: Os valores de dureza obtidos foram submetidos à análise de variância e ao teste de Tukey ao nível de 5%. Foi observado que a dureza dos corpos-de-prova variou conforme a cor do material e aparelhos utilizados. O aparelho LED que emite maior intensidade luminosa proporcionou a obtenção dos maiores valores de dureza, com o croma B-0,5 possibilitando a melhor polimerização. Por outro lado aparelhos com baixa intensidade luminosa foram os menos efetivos. Também foi observado que a região do fundo dos corpos-de-prova foi mais sensível à mudança das cores. CONCLUSÕES: A intensidade de luz dos fotopolimerizadores LED é fundamental para seu bom funcionamento, principalmente quando empregadas resinas com croma mais acentuado.


Assuntos
Instrumentos Odontológicos , Luz , Resinas Compostas , Dureza , Materiais Dentários
17.
J. appl. oral sci ; 14(1): 27-32, Jan.-Feb. 2006. ilus, tab, graf
Artigo em Inglês | LILACS, BBO | ID: lil-423355

RESUMO

Avaliação fotográfica para observar a presença ou a ausência de bolhas nos selantes de fóssula e fissuras Concise e Prisma Shield aos 7 dias, 18 meses, 36 meses e 11 anos, após a realização dos selamentos. METODOLOGIA: Foi aplicado na superfície oclusal, em todos os períodos de análise, uma solução corante a base de hematoxilina, que possibilitou a verificação e a avaliação dos materiais seladores presentes nesta superfície. Todas as superfícies oclusais foram fotografadas e as fotografias, correspondentes a cada período em análise, foram submetidas à avaliação fotográfica. RESULTADOS: Verificou-se diferença estatisticamente significativa somente aos 18 meses de análise, com o selante Prisma Shield apresentando um número significativamente maior de bolhas superficiais, que o selante Concise; enquanto que os demais grupos apresentaram-se estatisticamente semelhantes entre si, em todos os outros períodos de análise. Por outro lado, quando os selantes foram analisados isoladamente, nos períodos subseqüentes, não foi observada a presença de diferença estatisticamente significativa. CONCLUSÃO: De acordo com os resultados observados, pudemos verificar que os materiais seladores apresentaram o aparecimento e o desaparecimento de bolhas, fato que não interferiu na finalidade clínica do selamento realizado.


Assuntos
Humanos , Adolescente , Fotografia Dentária , Selantes de Fossas e Fissuras , Cárie Dentária , Materiais Dentários
18.
Arq. odontol ; 42(2): 113-123, 2006. ilus, tab
Artigo em Português | LILACS, BBO | ID: lil-457337

RESUMO

Esse artigo tem como objetivo avaliar a prevalência de fluorose dentária em adolescentes residentes em um município onde a fluoretação da água de abastecimento público estava em processo de implantação. A amostra foi selecionada por meio de sorteio das quadras em cada setor censitário e posteriormente das residências, totalizando 177 adolescentes e jovens, pertencentes à faixa etária de 11 a 19 anos. Os exames foram realizados nos domicílios, sob iluminação natural, por cirurgiões-dentistas devidamente treinados e calibrados (kappa=0,91), utilizando-se o índice de dean e metodologia preconizada pela Organização Mundial de Saúde. Observou-se que 6,21 por cento dos indivíduos apresentavam fluorose dentária, sendo 5,08 por cento grau 2(muito leve)e 1,13 por cento grau 3 (leve). Não foram observados nessa população os graus moderado e severo. A prevalência de fluorose encontrada foi baixa, de modo que essa doença não representa um problema de saúde pública no município pesquisado.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Halogenação/efeitos adversos , Fluorose Dentária/epidemiologia , Interpretação Estatística de Dados , Inquéritos de Saúde Bucal
19.
JBC j. bras. clin. odontol. integr ; 6(33): 235-238, maio-jun. 2002. ilus
Artigo em Português | LILACS, BBO | ID: lil-336102

RESUMO

Neste trabalho foram discutidos aspectos importantes relacionados à técnica do amálgama adesivo, bem como foi apresentado um caso clínico em que esta técnica foi empregada com sucesso


Assuntos
Humanos , Adulto , Amálgama Dentário , Restauração Dentária Permanente
20.
JBC j. bras. clin. odontol. integr ; 6(32): 117-128, mar.-abr. 2002. ilus
Artigo em Português | LILACS, BBO | ID: lil-345074

RESUMO

A aplicaçäo de selantes de fóssulas e fissuras pode ser considerada como um dos maiores avanços científicos obtidos dentro da Odontologia Preventiva. O sucesso clínico do selamento está diretamente relacionado com a adoçäo de uma técnica de aplicaçäo extremamente acurada, assim como com o controle periódico das superfícies que o receberam. Destacando, na oportunidade, que todos estes anos de estudo e dedicaçäo ao selante de fóssulas e fissuras possibilitou-nos concluir, entre outras consideraçöes, que, de fato, o que o profissional realmente necessita é conscientizaçäo da necessidade e da correta aplicaçäo desse material, fatores que, sem sombra de dúvidas, caminharäo juntos na prevençäo da cárie dental nos defeitos estruturais de esmalte (fóssulas e fissuras)


Assuntos
Cárie Dentária/prevenção & controle , Fissuras Dentárias/prevenção & controle , Selantes de Fossas e Fissuras
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA