Rev. nav. odontol ; 47(2): 18-25, out-nov 2020.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1366543

RESUMO

The aim of this study was to evaluate the influence of different surface treatments on bond strength (BS) between composite and a resin cement trough microshear bond strength test. Seventy five discs (10x2 mm) of Filtek P90, Filtek Z250 and Filtek Z350 XT (3M ESPE), were divided into 5 groups according to the treatment: C= control - no treatment; sandblasting J= aluminum oxide (50µm); sandblasting JE = + 99.3% ethanol for 5 min; silica coating S = (3M-ESPE Cojet - 30 microns); SS = silica coating + silane. PVC tubes (0.5 x 0.80 mm) were attached on the composite disc, and then, inserted resin cement (3M ESPE-RelyX ARC). After 24 hours artificial saliva storage at 37oC, the specimens were tested for microshear crosshead speed of 1.0 mm/min. Data were evaluated in two-way ANOVA and Tukey's test (5%) for contrast. The results showed that sandblasting with aluminum oxide (J) was efficient in increasing the BS for composites Z350 and P90. For the Z250, there were no difference between treatments. Also, CS showed results similar to controls for all composites. SE showed the worst results for Z350 e P90. BS values were dependent on the type of composite and the surface treatment used. Sandblasting with aluminum oxide seems to be an effective surface treatment for composites and may lead to higher BS values, while the use of ethanol could be harmful.


O objetivo deste estudo foi avaliar a influência de tratamentos de superfície na resistência de união (RU) entre compósitos e um cimento resinoso. Setenta e cinco discos (10x2 mm) das resinas Filtek P90, Filtek Z250 e Filtek Z350 (3M ESPE) foram divididos em 5 grupos de acordo com o tratamento: N= sem tratamento; S= jateamento com óxido de alumínio (50µm); SE= jateamento de óxido de alumínio + 99,3% de etanol por 5 min; C= jateamento de sílica com Cojet - 30 microns (3M ESPE); CS= jateamento de sílica + silano. Tubos de PVC (0,5 x 0,80 mm) foram fixados nos discos e o cimento resinoso (RelyX ARC, 3M ESPE) foi inserido. Após 24 horas de armazenamento em saliva artificial a 37oC, os espécimes foram submetidos ao teste de microcisalhamento com velocidade de 1,0 mm/min. Os dados foram avaliados em ANOVA de dois fatores e no teste de Tukey (5%) para contraste. Os resultados mostraram que o tratamento com oxido de alumínio (J) foi eficiente no aumento da RU nos compósitos Filtek Z350 e P90. Não houve diferença entre tratamentos para a Z250. Grupo CS mostrou resultados semelhantes aos do controle para todos os compósitos. Já o SE mostrou os piores resultados de RU. Concluiu-se que os valores de RU foram dependentes do tipo de compósito e do tratamento de superfície utilizado. O jateamento com óxido de alumínio parece ser um tratamento de superfície eficaz e pode elevar os valores de RU, já o uso de etanol pode ser prejudicial

2.
Rev. bras. odontol ; 69(1): 97-101, Jan.-Jun. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-718034

RESUMO

Apesar do advento dos implantes osseointegráveis, as próteses parciais fixas continuam a ser restaurações com larga utilidade no arsenal restaurador dos cirurgiões-dentistas. No entanto, a exigência estética dos dias atuais faz com que as próteses livres de metal ocupem o lugar das consagradas próteses metalocerâmicas. Sendo assim, diversos fatores devem ser compreendidos e avaliados para se planejar a confecção de uma prótese parcial fixa totalmente cerâmica. O objetivo desta revisão é expor os fatores que podem determinar o sucesso ou fracasso de próteses parciais fixas totalmente cerâmicas.


Despite the advent of osseointegrated implants, fixed partial dentures remain to have a broad utility in the restorative arsenal of the dentists. However, modern day esthetic requirements causes metal-free prosthesis take the place once occupied in the past by the classic porcelain fused to metal FPDs. This way, several factors must be understood and assessed to plan the fabrication of an all- -ceramic fixed partial denture. The purpose of this review article is to look at the factors that can determine success or failure of all-ceramic fixed partial dentures.


Assuntos
Humanos , Cerâmica , Prótese Parcial Fixa , Prótese Parcial Fixa/efeitos adversos
3.
Rev. bras. odontol ; 69(1): 55-60, Jan.-Jun. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-718026

RESUMO

Este estudo buscou comparar a estabilidade dimensional de modelos após moldagem com poliéter (P), silicone de adição espatulado mecanicamente (SAP) e manualmente (SAM), desinfetados com hipoclorito de sódio 1% (HP), ácido peracético 0,2% (AP) e sem desinfecção. Foram feitas mensurações cruzando o arco posterior (CAP) e anterior (CAA), ântero-posterior direita (APD) e esquerda (APE). A análise estatística (Kruskal-Wallis) mostrou que houve diferença significativa apenas na medida CAP: 1) entre P (0,1203% ± 0,0442) e SAP (0,0350% ± 0,0158) desinfetados com HP; 2) entre P (0,1345% ± 0,1059) e SAP (0,0264%± 0,0302) desinfetados com AP; 3) entre os grupos SAM (0,1054% ± 0,0419) e SAP (0,0264% ± 0,0302). A desinfecção com ácido peracético e hipoclorito de sódio não interferiu negativamente na estabilidade dimensional das moldagens realizadas neste estudo.


This study aimed to compare the dimensional stability of polyether (P), addition silicone auto mixed (ASP) and addition silicone hand mixed (ASM) molds after disinfection with sodium hypochlorite 1% (HP), peracetic acid 0,2% (AP), and no disinfection. Mensurations cross posterior arch (CAP), cross-anterior arch (CAA), and antero-posterior on right (APD) and left sides (APE). Statistical analysis (Kruskall-Wallis) showed significant difference only in measure CAP: 1) between P (0,1203% ± 0,0442) and SAP (0,0350% ± 0,0158) disinfected with HP; 2) between P (0,1345% ± 0,1059) and SAP (0,0264% ± 0,0302) disinfected with AP; and 3) between SAM (0,1054% ± 0,0419) and SAP (0,0264% ± 0,0302). Disinfection with peracetic acid and sodium hypochlorite did not interfere negatively in the dimensional accuracy of the impressions tested in this study. Keywords: impression materials; disinfection; peracetic acid; sodium hypochlorite.


Assuntos
Odontologia
4.
Rev. Clín. Ortod. Dent. Press ; 11(1): 98-106, fev.mar. - 2012. ilus
Artigo em Português | LILACS, BBO | ID: biblio-855873

RESUMO

O objetivo deste estudo foi avaliar o sucesso de um implante osseointegrado, submetido a forças protéticas e ortodônticas imediatas, durante um período de acompanhamento de 63 meses. Um implante protético foi colocado em paciente com ausência do elemento 35, com intuito de servir de ancoragem para movimentação ortodôntica e para substituir o dente ausente. Um torque inicial mínimo de 40N/cm era necessário para permitir carga oclusal imediata. Imediatamente após a cirurgia, uma coroa provisória de resina acrílica foi confeccionada com um componente protético antirrotacional temporário torqueado a 20N/cm; um braquete ortodôntico foi colado na superfície vestibular com resina acrílica. Dois dias após a cimentação da coroa provisória, uma força de 2N (?204g) foi aplicada ao implante através do uso de um arco de aço inoxidável 0,018” contínuo. Avaliações clínica e radiográfica foram realizadas 6, 43 e 63 meses após o início da movimentação ortodôntica. Os resultados foram animadores, com ausência de sinais e sintomas negativos. Após seguir os critérios determinados, obteve-se sucesso na aplicação de carga imediata no implante endósseo. O sucesso em longo prazo desse caso deve estimular o desenvolvimento de estudos futuros antes que esse procedimento se torne uma rotina.


Assuntos
Humanos , Feminino , Adulto Jovem , Carga Imediata em Implante Dentário , Técnicas de Movimentação Dentária/métodos , Procedimentos de Ancoragem Ortodôntica , Ortodontia