Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Adicionar filtros








Intervalo de ano
1.
Indian J Ophthalmol ; 2019 Oct; 67(10): 1555-1559
Artigo | IMSEAR | ID: sea-197507

RESUMO

Purpose: To compare refractive measurements of noncycloplegic photoscreener Plusoptix S12R with cycloplegic retinoscopy, noncycloplegic autorefractor, and cycloplegic autorefractor in children. Methods: The study population (200 eyes of 100 children) was divided into two groups: Group 1 (age 3–7 years) and Group 2 (age 8–15 years). In Group 1, Plusoptix was compared with cycloplegic retinoscopy. In Group 2, Plusoptix was compared with cycloplegic retinoscopy and autorefraction. The second group was made because the younger group was found to be uncooperative for autorefraction. Paired t-test and Pearson's correlation were used for statistical analysis. Results: The mean difference in sphere (DS), spherical equivalent (DSE), and cylinder (DC) between cycloplegic retinoscopy and Plusoptix in Group 1 was 0.68 ± 0.55 (P < 0.001), 0.77 ± 0.61 (P < 0.001), and 0.18 ± 0.28 (P < 0.001), respectively. In Group 2, DS, DSE, and DC between cycloplegic retinoscopy and Plusoptix were 0.86 ± 0.49 (P < 0.001), 0.97 ± 0.51 (P < 0.001), and 0.23 ± 0.28 (P < 0.001); between cycloplegic autorefractor and Plusoptix were 0.69 ± 0.47 (P < 0.001), 0.74 ± 0.49 (P < 0.001), and 0.10 ± 0.31 (P = 0.002); and between noncycloplegic autorefractor and Plusoptix were ? 0.25 ± 0.39 (P < 0.001), ?0.19 ± 0.41 (P < 0.001), and 0.11 ± 0.31 (P < 0.001), respectively. Pearson's correlation coefficients of S, SE, and C between Plusoptix and cycloplegic retinoscopy were 0.948, 0.938, and 0.924 in Group 1 and 0.972, 0.972, and 0.946 in Group 2, and these values were statistically significant. Bland–Altman plots showed good agreement between cycloplegic retinoscopy and Plusoptix in both groups. Plusoptix gave axis values within 10° of cycloplegic retinoscopy in 81.56% of eyes in Group 1 and in 71.44% of eyes in Group 2. Conclusion: Plusoptix photoscreener can be used for prescription of axis of cylinder in children; however, other refractive measurements must be refined by cycloplegic retinoscopy.

2.
Indian J Ophthalmol ; 2019 Feb; 67(2): 213-216
Artigo | IMSEAR | ID: sea-197137

RESUMO

Purpose: To evaluate the difficulty perceived of each step of phacoemulsification and analyze the factors affecting them. Methods: Overall, 12 trainee residents were allotted 10 cases of phacoemulsification of eyes with senile cataract, under a single observer, and the steps of each surgery were rated from very easy to very difficult with a questionnaire. The completion rates of steps and complications of each surgery were noted. Principal component analysis of the responses to the difficulty level questionnaire was conducted to obtain factors resulting in the perceived difficulty. Results: The lowest difficulty scores were for initial step of incision creation (1.63 � 0.84), followed by intraocular lens insertion (2.51 � 0.8). The most difficult step was divide/chop of the nucleus (3.74 � 0.97) followed by phacoemulsification (3.32 � 0.82). Highest completion rates were seen for the initial steps of the surgery and the lowest for divide/chop. We identified two major patterns of difficulty among the trainees � one for steps involving high amount of binocularity and the other, for steps involving high precision of hand control. The rate of complication of our study was within acceptable range. Conclusion: Although trainees have practiced phacoemulsification steps on simulation, real-life situation may bring in unprecedented level of difficulty and challenges, which may be documented and used for targeted improvement of surgical skills. Stereopsis and hand control training should form a major part of training modules of cataract surgery both on simulation and real-life scenarios.

3.
J Vector Borne Dis ; 2009 Sept; 46(3): 244-246
Artigo em Inglês | IMSEAR | ID: sea-142693
4.
Artigo em Inglês | IMSEAR | ID: sea-134841

RESUMO

Paraphimosis has been described by standard text books of forensic medicine as a cause of temporary impotence but present case suggests that it can be an evidence of sexual activity / intercourse also.


Assuntos
Adulto , Coito , Disfunção Erétil , Feminino , Medicina Legal , Humanos , Parafimose/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA