Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of the Korean Ophthalmological Society ; : 423-430, 2023.
Artigo em Coreano | WPRIM | ID: wpr-977095

RESUMO

Purpose@#To investigate the long-term outcomes of anterior chamber angle parameters in patients with primary angle closure glaucoma (PACG) after peripheral laser iridotomy (LI) combined with iridoplasty (PI) using a dual Scheimpflug analyzer. @*Methods@#This retrospective study included 32 eyes in 32 patients diagnosed with PACG who underwent LI plus PI. Patients with an acute angle closure crisis were excluded. Dual Scheimpflug analyzer images were acquired before and 1 week after LI plus PI, and yearly afterwards. Anterior chamber depth (ACD) and volume (ACV), mean anterior chamber angle (ACA), and intraocular pressure (IOP) were also measured. @*Results@#The mean follow-up was 32.28 ± 13.34 months. Baseline demographics were age 63 ± 7.9 years, 62.5% female, IOP 15.48 ± 4.79 mmHg, ACD 2.09 ± 0.19 mm, and visual field mean deviation -7.97 ± 8.49 dB. ACD increased from baseline to 2.15 ± 0.32 mm, but it was not significant (p = 0.136). ACV increased significantly from 78.32 ± 11.49 mm at baseline to 83.04 ± 11.16 mm at the last visit after LI (p = 0.011). The mean ACA increased significantly from 26.86 ± 2.53° at baseline to 28.82 ± 4.64° at the last visit (p = 0.022). IOP decreased significantly from baseline to 13.06 ± 2.21 mmHg at the last visit (p = 0.001). @*Conclusions@#The ACA parameters improved after LI combined with PI in patients with PACG and remained so on long-term follow-up. IOP was also significantly reduced for more than 2.5 years after LI plus PI.

2.
Korean Journal of Otolaryngology - Head and Neck Surgery ; : 999-1003, 2008.
Artigo em Coreano | WPRIM | ID: wpr-654708

RESUMO

BACKGROUND AND OBJECTIVES: The goal of this study was to examine insertion depth, intracochlear position and insertion trauma with the stimulation electrode of the Nurobiosys cochlear implant. SUBJECTS AND METHOD: Four electrodes were implanted in fresh temporal bones of the human cadavers using realistic surgical procedures. Plain film X-ray images were taken from the electrode inserted in the specimens to estimate the insertion depth. After the electrode implantation, all human temporal bones were trimmed to extract the cochleae. The extracted cochleae from the temporal bone were immersed in acrylic resin to fix the position of electrode placed in the scala tympani. The resin treated cochleae were cut in radial section and polished. All crosssections were imaged with a microscope to assess the trauma by the electrode implantation. RESULTS: The mean insertion depth was about 300degrees with the cochlea angle. The insertion trauma was observed in one section of a temporal bone. The mean distance from electrode to modiolus was about 0.75 millimeter. CONCLUSION: The incidence, severity of trauma and insertion depth of the studied electrode showed similar results with that of other straight type electrode in literature.


Assuntos
Humanos , Cadáver , Cóclea , Implantes Cocleares , Eletrodos , Incidência , Rampa do Tímpano , Osso Temporal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA