Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Adicionar filtros








Intervalo de ano
1.
Arq. bras. oftalmol ; 86(5): e20230059, 2023. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513682

RESUMO

ABSTRACT We report a case of acute corneal hydrops followed by corneal perforation five years after corneal cross-linking for keratoconus. A healthy 24-year-old female patient underwent Dresden protocol cross-linking in her left eye due to advanced keratoconus. After five years of a stable cornea, she returned with epiphora, blurred vision, and a soft left eye. Acute hydrops and corneal perforation were diagnosed. There was no history of pregnancy, atopy, eye rubbing, trauma, or contact lens use. Local antibiotic and eye patching were applied. Three months after the resolution of the acute episode, she retained useful visual acuity with no need for further surgery. Although cross-linking efficiently halts keratoconus, progression can occur, leading to corneal hydrops and perforation, even in the absence of any risk factors.


RESUMO Este é o relato de um caso de hidropisia aguda seguida de perfuração corneana cinco anos após reticulação corneana para ceratocone. Uma paciente saudável de 24 anos foi submetida a reticulação corneana no olho esquerdo pelo protocolo de Dresden, devido a um ceratocone avançado. Após cinco anos com a córnea estável, a paciente retornou com epífora, visão turva e amolecimento do olho esquerdo. Foram diagnosticadas hidropisia aguda e perfuração corneana. A paciente não tinha história de gravidez, atopia, fricção ocular, trauma ou uso de lentes de contato. Foram aplicados um antibiótico local e um tampão oftalmológico. Três meses após a resolução do episódio agudo, ela manteve uma acuidade visual útil, sem necessidade de novas cirurgias. Embora a reticulação interrompa de forma eficiente o ceratocone, pode ocorrer progressão, levando a hidropisia e perfuração da córnea, mesmo na ausência de fatores de risco.

2.
Rev. bras. oftalmol ; 73(4): 220-224, Jul-Aug/2014. tab, graf
Artigo em Português | LILACS | ID: lil-730578

RESUMO

Objetivo: Verificar índices tomográficos do pré-operatório de pacientes com ceratocone submetidos à crosslinking corneano (CXL) como fatores preditivos para a melhora na acuidade visual corrigidas (AVc) após um ano. Métodos: Estudo retrospectivo que incluiu 63 olhos de 53 pacientes com ceratocone progressivo submetidos à CXL segundo o protocolo de Dresden: deseptelização corneana, riboflavina 0,1% por 30 minutos e luz ultra-violeta A (UVA) a uma irradiância de 3mW/cm2 por 30 minutos. Foram avaliados exames de tomografia corneana com sistema de Scheimpflug rotacional (Pentacam, Oculus) antes do CXL e a acuidade visual corrigida antes e após a cirurgia. A análise estatística foi feita com o teste de Kolmorov-Smirnov, teste t de student e curvas de característica operador-receptor (ROC). Resultados: Houve diferença estatisticamente significante (p<0,05) entre os pacientes que obtiveram melhora de AVc em um ano e os que não experimentaram melhora na AVc nesse período nos índices tomográficos pré-operatórios relacionados com espessura e volume corneano. Entre os pacientes que obtiveram melhora na AVc todos possuíam volume corneano em 6,0mm maior que 14,55mm3 e 97,2% deles possuíam volume corneano em 6,5mm maior que 17,76mm3. Assim como, 94,29% desses pacientes apresentavam paquimetria média em 4,0mm maior que 487 μm e 82,86% paquimetria no ponto mais fino maior de 421 μm. Conclusão: Pacientes com ceratocone menos avançado (volume e espessura da córnea maiores) no período pré-operatório obtiveram mais chances de ter melhora da AVc um ano após CXL. Estudos prospectivos envolvendo outras variáveis relacionadas com a aberrometria total e o estudo biomecânico da córnea são relevantes para se aumentar a capacidade prognóstica do resultado após CXL. .


Purpose: To verify pre-operative tomographic indices as predictive parameters for the improvement in best corrected visual acuity (BCVA) in one year after corneal collagen crosslinking (CXL) procedure for keratoconus. Methods: Retrospective study that included 63 eyes of 53 patients with progressive keratoconus submitted to CXL following the Dresden’s protocol: topical anesthesia, 9.0 mm of epithelial abrasion, riboflavin 0.1% drops for 30 minutes and ultraviolet-light A (UVA) with an irradiance of 3mW/cm2 for 30 minutes. Corneal tomography taken by Scheimplug rotational system (Pentacam, Oculus) before CXL was evaluated along with pre and 1 year post-operative BCVA. Statistical analysis was accomplished with the Kolmogorov-Smirnov test, student’s t-test and Receiver Operating Characteristic (ROC) curve. Results: There were statistically significant differences (p<0.05) between patients who improved BCVA in one year after CXL and those who did not experienced improvement in BCVA in the same period of time in the pre-operative tomographic indices related to corneal volume and thickness. Among those who had its BCVA improved all of them had a corneal volume in 6.0mm grater then 14.55mm3 and 97.2% of them had corneal volume in 6.5mm grater then 17.76mm3. So with 94.29% of them hadthickness in 4.0mm grater then 487μm and 82.86% had thickness on the thinnest point grater then 421μm. Conclusion: Patients with less advanced keratoconus (grater corneal volume and thickness) in the pre-operative had more chances to improve its BCVA in one year after CXL. Prospective studies involving others variables related to total aberrometry and corneal biomechanics are relevant to increase the prognostic capability of CXL result. .


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Prognóstico , Riboflavina/uso terapêutico , Raios Ultravioleta , Reagentes de Ligações Cruzadas , Ceratocone/terapia , Cuidados Pré-Operatórios , Estudos Retrospectivos , Colágeno/efeitos da radiação , Colágeno/metabolismo , Fármacos Fotossensibilizantes/uso terapêutico , Córnea/efeitos dos fármacos , Córnea/efeitos da radiação , Córnea/metabolismo , Tomografia de Coerência Óptica , Ceratocone/fisiopatologia , Ceratocone/metabolismo
3.
Indian J Ophthalmol ; 2013 Aug; 61(8): 381
Artigo em Inglês | IMSEAR | ID: sea-149579
4.
Arq. bras. oftalmol ; 65(6): 679-684, nov.-dez. 2002. ilus
Artigo em Português | LILACS | ID: lil-324559

RESUMO

A luz se propaga uniformemente a partir de um ponto luminoso na mesma velocidade em todas as direções. Sua posição em cada determinado momento é uma esfera formada juntando-se todos os pontos em uma mesma fase e tendo como centro a sua própria fonte. Tais superfícies esféricas imaginárias chamam-se frentes de luz ou frentes de ondas. Há três fatores limitadores de detalhes mais finos para o olho humano: óptico (por causa da dispersão, difração, aberração cromática e aberração monocromática), retínico e neural (limitação máximade acuidade visual de aproximadamente 2,0 ou 20/10).Um sistema de equações matemáticas, polinômios de Zernike, pode definir superfícies geométricas para descrever aberrações ópticas monocromáticas, tanto as de baixa ordem (`prisma', `esfera' e 'astigmatismo'), quanto às de alta ordem (`coma', `aberração esférica' e outros). Medida das aberrações ópticas nos dá informação sobre o desempenho total de todos os elementos ópticos do olho em conjunto. Dois sistemas descritos aqui, o aberrômetro baseado no princípio de Tscherning e o originado do sensor Hartmann-Shack, têm a mesma lógica: comparar a posição atual das frentes de onda com a ideal, calcular matematicamentequal é a superfície geométrica que descreve essa discrepância e representa-la em termos de polinômios de Zernike. A topografia corneana computadorizada também pode, com "software" adequado, descrever as frentes de ondas definidas por irregularidades corneanas com polinômios de Zernike, porém tal caracterização representa somente a superfície anterior da córnea. Em conclusão, a tecnologia de frentes de ondas oferece nova maneira de quantificar e classificar os erros de imagem óptica do olho humano. O próximo artigo abordará as peculiaridades da análise de frentes de ondas, bem como algumas aplicações clínicas e cirúrgicas no dia-a-dia da prática oftalmológica.


Assuntos
Córnea , Topografia da Córnea , Luz , Acuidade Visual , Refração Ocular/fisiologia , Erros de Refração
5.
Arq. bras. oftalmol ; 65(6): 685-690, nov.-dez. 2002. ilus, graf
Artigo em Português | LILACS | ID: lil-324560

RESUMO

Os valores médios de todas os coeficientes de Zemike são de aproximadamente zero, ao passo que a variabilidade individual é muito grande, o que significa que os seres humanos, como espécie em geral, têm sistema óptico muito bom, mas individualmente imperfeito. Certa instabilidade temporal das aberrações de alta ordem foi descrita em função da acomodação. Este fato leva a uma nova pergunta: a correção de todas as aberrações para visão em estado não acomodado será benéfica para visão de perto também? É possível modificar e diminuir as aberrações ópticas por meio de foto-ablação por "seanning spot LASER" tendo os dados das frentes de ondas como a base para perfil de ablação individualizado. É fundamental afixação perfeita do feixe de "LASER" em relação ao olho, obtida com os "eye-trackers" de alta freqüência. O beneficio visual teórico da correção das aberrações de alta ordem seria de até 12 vezes. A meta principal dos tratamentos guiados pelas frentes de onda é de não permitir a piora da visão depois do tratamento cirúrgico refrativo, como pode ocorrer hoje em dia com os tratamentos tradicionaig a "LASER"; em seguida, a meta se estenderia aos melhoramentos visuais, bem como ao tratamento dos casos de córneas extremamente irregulares (ablações primárias irregulares, pequenas ou descentradas, a presença das ilhas centrais ou irregularidades após transplante de córnea). O entendimento da terminologia e das bases da nova evolução tecnológica, bem como o constante acompanhamento crítico dos resultados publicados é fundamental para a abordagem moderna dos problemas relativos à refração e á cirurgia refrativa.


Assuntos
Córnea , Topografia da Córnea , Luz , Erros de Refração , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA