Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Clinics in Shoulder and Elbow ; : 205-209, 2020.
Artigo em Inglês | WPRIM | ID: wpr-890266

RESUMO

Simple clavicle shaft fracture typically achieves satisfactory union after treatment and does not result in complication with conservative treatment. Non-union or malunion can occur in displaced clavicle fractures or comminuted shaft fractures. Treatment of displaced comminuted clavicle shaft fractures is performed by holding together the free fragments with interfragmentary screws or wires and fixing them to the clavicle with a plate. Therefore, we performed interfragmentary fixation using open reduction and internal fixation with bioresorbable screws (Mg-Ca alloy, Resomet Bioresorbable bone screw; U&I Corp.) and bioresorbable wires (Mg-Ca alloy, Resomet Bioresorbable K-wire and pin, U&I Corp.) for displaced comminuted clavicle fractures (Robinson type 2B) and additionally used a metal plate. We expected decreased irritation and infection due to absorption after surgery. We report four cases that were treated in this way.

2.
Clinics in Shoulder and Elbow ; : 205-209, 2020.
Artigo em Inglês | WPRIM | ID: wpr-897970

RESUMO

Simple clavicle shaft fracture typically achieves satisfactory union after treatment and does not result in complication with conservative treatment. Non-union or malunion can occur in displaced clavicle fractures or comminuted shaft fractures. Treatment of displaced comminuted clavicle shaft fractures is performed by holding together the free fragments with interfragmentary screws or wires and fixing them to the clavicle with a plate. Therefore, we performed interfragmentary fixation using open reduction and internal fixation with bioresorbable screws (Mg-Ca alloy, Resomet Bioresorbable bone screw; U&I Corp.) and bioresorbable wires (Mg-Ca alloy, Resomet Bioresorbable K-wire and pin, U&I Corp.) for displaced comminuted clavicle fractures (Robinson type 2B) and additionally used a metal plate. We expected decreased irritation and infection due to absorption after surgery. We report four cases that were treated in this way.

3.
Journal of the Korean Ophthalmological Society ; : 715-720, 2015.
Artigo em Coreano | WPRIM | ID: wpr-226694

RESUMO

PURPOSE: To compare pain levels in cataract surgery under topical anesthesia only and topical anesthesia under monitored anesthesia care. METHODS: We recruited 243 patients who were scheduled to undergo cataract surgery under topical anesthesia only or topical anesthesia with monitored anesthesia care (MAC) using fentanyl and midazolam. Anesthesia methods were selected based on the patient's preference. All patients completed an anxiety and information scale survey preoperatively. Vital signs during the operations were recorded. A 0-to-10 visual analog scale pain score survey was conducted immediately and at 2 hours, 6 hours, and 1 day after surgery. RESULTS: Of the 237 patients who completed the study, 183 patients selected topical anesthesia, and 54 patients selected MAC. Mean pain scores according to the aforementioned time points after surgery were 0.50, 0.58, 0.29, and 0.12 in the topical anesthesia group, and 0.22, 0.16, 0.06, and 0.09 in the MAC group, respectively. The differences in pain score between the two groups was statistically significant at 2 hours (p = 0.019) and 6 hours (p = 0.040) after surgery. The mean patient anxiety score for anesthesia was 10.50 in the topical anesthesia group and 11.41 in the MAC group (p = 0.280). Mean systolic blood pressure at the start of surgery was 140.6 mm Hg in the topical anesthesia group, and 158.2 mmHg in the MAC group. CONCLUSIONS: Monitored anesthesia care consistently resulted in less pain throughout the post-operative period. However, transient systolic blood pressure should be carefully monitored for a rise related to intravenous anesthetics.


Assuntos
Humanos , Anestesia , Anestésicos Intravenosos , Ansiedade , Pressão Sanguínea , Catarata , Fentanila , Midazolam , Escala Visual Analógica , Sinais Vitais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA