1.
The Journal of the Korean Orthopaedic Association ; : 240-245, 1998.
Artigo em Coreano | WPRIM | ID: wpr-644594

RESUMO

Many uncemented acetabular components use transfixation screws to stabilize the acetabular component until ingrowth of bone occurs. But the use of transacetabular screw fixation in total hip arthroplasty could increase the incidence of intrapelvic complications including neurovascular injury, extrinsic compression and erosion of intrapelvic organs. Metal debris was attributed to corrosion or fretting between screw and metal shell may lead to pelvic osteolysis. A foreign body reaction to metal and polyethylene wear debris in a loose acetahular component eroded the medial wall of the acetabulum and produced an intrapelvic mass. We experienced a case of intrapelvic pseudocyst in a failed total hip arthroplasty. The cyst communicated with hip joint through the transacetabular fixation screw which was placed near the center of the acetahulum.


Assuntos
Acetábulo , Artroplastia de Quadril , Corrosão , Citocromo P-450 CYP1A1 , Reação a Corpo Estranho , Quadril , Articulação do Quadril , Incidência , Osteólise , Polietileno
2.
The Journal of the Korean Orthopaedic Association ; : 959-967, 1998.
Artigo em Coreano | WPRIM | ID: wpr-652730

RESUMO

Synthetic hydroxyapatite is a safe, nontoxic, biocompatible, and osteoconductive material. Hydroxyapatite-coated implants have the property of achieving a very strong bond with living bone in a relatively short period. From March 1992 to June 1994, 140 hydroxyapatite-coated primary total hip prostheses were implanted. This study included 60 cases that could follow up minimum 3 years. At the time of mean follow up, 45 months after operation, the mean Harris hip score was 92 points. Only two patients complained of thigh pain at last follow up. On radiographic evaluation, radiolucent lines were seen around the uncoated distal part of the stem in 46 percents of the implants. No radiolucent line was observed around the coated area of the prosthesis. Cancellous condensation was seen in 95 per cents of the implants at the Gruen zone 2 and 6 area. Cortical hypertrophy was present in 32 percents. Fourteen cases had the gaps at the bone to acetabular cup interface in the immediate postoperative period. The gaps disappeared in 12 months after operation. Five implants were revised because of polyethylene wear, cup migration and periprosthetic fracture. The clinical outcome was excellent. But this result was obtained in the relatively short-term follow up. Longer-term data will be the only true test of the value of hydroxyapatite coated implant.


Assuntos
Humanos , Acetábulo , Artroplastia de Quadril , Durapatita , Seguimentos , Prótese de Quadril , Quadril , Hipertrofia , Fraturas Periprotéticas , Polietileno , Período Pós-Operatório , Próteses e Implantes , Coxa da Perna