RESUMO
Objective@#Differentiating intracranial aneurysms from normal variants using CT angiography (CTA) or MR angiography (MRA) poses significant challenges. This study aimed to evaluate the efficacy of proton-density MRA (PD-MRA) compared to highresolution time-of-flight MRA (HR-MRA) in diagnosing aneurysms among patients with indeterminate findings on conventional CTA or MRA. @*Materials and Methods@#In this retrospective analysis, we included patients who underwent both PD-MRA and HR-MRA from August 2020 to July 2022 to assess lesions deemed indeterminate on prior conventional CTA or MRA examinations. Three experienced neuroradiologists independently reviewed the lesions using HR-MRA and PD-MRA with reconstructed voxel sizes of 0.253 mm3 or 0.23 mm3 , respectively. A neurointerventionist established the gold standard with digital subtraction angiography.We compared the performance of HR-MRA, PD-MRA (0.253 -mm3 voxel), and PD-MRA (0.23 -mm3 voxel) in diagnosing aneurysms, both per lesion and per patient. The Fleiss kappa statistic was used to calculate inter-reader agreement. @*Results@#The study involved 109 patients (average age 57.4 ± 11.0 years; male:female ratio, 11:98) with 141 indeterminate lesions. Of these, 78 lesions (55.3%) in 69 patients were confirmed as aneurysms by the reference standard. PD-MRA (0.253 -mm3voxel) exhibited significantly higher per-lesion diagnostic performance compared to HR-MRA across all three readers: sensitivity ranged from 87.2%–91.0% versus 66.7%–70.5%; specificity from 93.7%–96.8% versus 58.7%–68.3%; and accuracy from 90.8%–92.9% versus 63.8%–69.5% (P ≤ 0.003). Furthermore, PD-MRA (0.253 -mm3 voxel) demonstrated significantly superior per-patient specificity and accuracy compared to HR-MRA across all evaluators (P ≤ 0.013). The diagnostic accuracy of PD-MRA (0.23 -mm3 voxel) surpassed that of HR-MRA and was comparable to PD-MRA (0.253 -mm3 voxel). The kappa values for inter-reader agreements were significantly higher in PD-MRA (0.820–0.938) than in HR-MRA (0.447–0.510). @*Conclusion@#PD-MRA outperformed HR-MRA in diagnostic accuracy and demonstrated almost perfect inter-reader consistency in identifying intracranial aneurysms among patients with lesions initially indeterminate on CTA or MRA.
RESUMO
Purpose@#To propose standardized and feasible imaging protocols for constructing artificial intelligence (AI) database in acute stroke by assessing the current practice at tertiary hospitals in South Korea and reviewing evolving AI models. @*Materials and Methods@#A nationwide survey on acute stroke imaging protocols was conducted using an electronic questionnaire sent to 43 registered tertiary hospitals between April and May 2021. Imaging protocols for endovascular thrombectomy (EVT) in the early and late time windows and during follow-up were assessed. Clinical applications of AI techniques in stroke imaging and required sequences for developing AI models were reviewed. Standardized and feasible imaging protocols for data curation in acute stroke were proposed. @*Results@#There was considerable heterogeneity in the imaging protocols for EVT candidates in the early and late time windows and posterior circulation stroke. Computed tomography (CT)-based protocols were adopted by 70% (30/43), and acquisition of noncontrast CT, CT angiography and CT perfusion in a single session was most commonly performed (47%, 14/30) with the preference of multiphase (70%, 21/30) over single phase CT angiography. More hospitals performed magnetic resonance imaging (MRI)-based protocols or additional MRI sequences in a late time window and posterior circulation stroke. Diffusion-weighted imaging (DWI) and fluid-attenuated inversion recovery (FLAIR) were most commonly performed MRI sequences with considerable variation in performing other MRI sequences. AI models for diagnostic purposes required noncontrast CT, CT angiography and DWI while FLAIR, dynamic susceptibility contrast perfusion, and T1-weighted imaging (T1WI) were additionally required for prognostic AI models. @*Conclusion@#Given considerable heterogeneity in acute stroke imaging protocols at tertiary hospitals in South Korea, standardized and feasible imaging protocols are required for constructing AI database in acute stroke. The essential sequences may be noncontrast CT, DWI, CT/MR angiography and CT/MR perfusion while FLAIR and T1WI may be additionally required.
RESUMO
Purpose@#Identifying current practices in acute stroke imaging is essential for establishing optimal imaging protocols. We surveyed and assessed the current status of acute stroke imaging for endovascular thrombectomy (EVT) at tertiary hospitals throughout South Korea. @*Materials and Methods@#An electronic questionnaire on imaging protocols for EVT in patients with acute ischemic stroke was e-mailed to physicians at 42 registered tertiary hospitals, and their responses were collected between February and March 2020. @*Results@#Of the 36 hospitals participating in the survey, 69% (25/36) adopted computed tomography (CT)-based protocols, whereas 31% (11/36) adopted magnetic resonance (MR)-based protocols. Non-enhanced CT (NECT) was the initial imaging study at 28%, NECT with CT angiography (CTA) at 36%, and NECT with CTA and CT perfusion (CTP) at 33% of hospitals. Perfusion imaging was performed at 61% (22/36), CTP at 44% (16/36), and MR perfusion at 17% (6/36) of hospitals. Multiphase CTA was performed at 67%, single-phase CTA at 11%, time-of-flight MR angiography (MRA) at 8%, contrast-enhanced MRA at 8%, and both at 6% of hospitals. For late time window stroke, 50% of hospitals used identical imaging protocols to those for early time window stroke, 39% used additional MR imaging (MRI), and 6% converted the imaging strategy from CT to MRI. Post-processing programs were used at 28% (10/36), and RAPID software at 14% (5/36) of hospitals, respectively. Most hospitals (92%) used the same imaging protocols for posterior and anterior circulation strokes. @*Conclusion@#Our multicenter survey demonstrated considerable heterogeneity in acute stroke imaging protocols across South Korean tertiary hospitals, suggesting that hospitals refine their imaging protocols according to hospital-specific conditions.
RESUMO
Background and Objectives@#Leaflet thrombosis after transcatheter aortic valve replacement (TAVR) has been reported recently, whereas thrombus formation in sinus of Valsalva has yet to be fully evaluated. This study describes clinical and cardiac computed tomography (CT) findings of patients with sinus of Valsalva thrombosis. @*Methods@#Between March 2011 and Aug 2019, 192 patients underwent cardiac CT after TAVR. After a retrospective review of CT images, 9 patients (82 years, male:female=2:7) who had sinus of Valsalva thrombosis identified by cardiac CT were selected for this study. Patient demographics, interval between TAVR and cardiac CT scan, location and CT attenuation of sinus of Valsalva thrombosis, and presence of concurrent leaflet thrombosis were evaluated. @*Results@#The median interval between TAVR and cardiac CT was 11 days. Sinus of Valsalva thrombosis was frequently detected in the non-coronary sinus (89%, 8/9), and predominantly located in the bottom of the sinus extending upward towards the sinotubular junction. Three patients had concomitant leaflet thrombosis, and 3 patients had subclinical embolic stroke noted on brain magnetic resonance imaging. All patients had been prescribed aspirin and clopidogrel after TAVR for at least 6 months without anticoagulants. @*Conclusions@#Cardiac CT after TAVR can detect sinus of Valsalva thrombosis, and attention should be paid to this potential source of subsequent systemic embolization.
RESUMO
OBJECTIVE: We aimed to determine the optimized image-based surrogate endpoints (IBSEs) in targeted therapies for glioblastoma through a systematic review and meta-analysis of phase III randomized controlled trials (RCTs).MATERIALS AND METHODS: A systematic search of OVID-MEDLINE and EMBASE for phase III RCTs on glioblastoma was performed in December 2017. Data on overall survival (OS) and IBSEs, including progression-free survival (PFS), 6-month PFS (6moPFS), 12-month PFS (12moPFS), median PFS, and objective response rate (ORR) were extracted. Weighted linear regression analysis for the hazard ratio for OS and the hazard ratios or odds ratios for IBSEs was performed. The associations between IBSEs and OS were evaluated. Subgroup analyses according to disease stage (newly diagnosed glioblastoma versus recurrent glioblastoma), types of test treatment, and types of response assessment criteria were performed.RESULTS: Twenty-three phase III RCTs published between 2000 and 2017, including 8387 patients, met the inclusion criteria. OS showed strong correlations with PFS (standardized β coefficient [R] = 0.719), 6moPFS (R = 0.647), and 12moPFS (R = 0.638). OS showed no correlations with median PFS and ORR. In subgroup analysis according to types of therapies, PFS showed the highest correlations with OS in targeted therapies for cell cycle pathways (R = 0.913) and growth factor receptors and their downstream pathways (R = 0.962). 12moPFS showed the highest correlation with OS in antiangiogenic therapy (R = 0.821). The response assessment in neuro-oncology criteria provided higher correlation coefficients between OS and IBSEs than the Macdonald criteria.CONCLUSION: Overall, PFS is an optimized IBSE in targeted therapies for glioblastoma; however, 12moPFS is optimal in antiangiogenic therapy.
RESUMO
Assuntos
Humanos , Ásia , Povo Asiático , Educação , Cooperação Internacional , Oceania , SeulRESUMO
OBJECTIVE: To compare conventional sensitivity encoding (SENSE) to compressed sensing plus SENSE (CS) for high-resolution magnetic resonance imaging (HR-MRI) of intracranial and extracranial arteries. MATERIALS AND METHODS: HR-MRI was performed in 14 healthy volunteers. Three-dimensional T1-weighted imaging (T1WI) and proton density-weighted imaging (PD) were acquired using CS or SENSE under the same total acceleration factors (AF(t))-5.5, 6.8, and 9.7 for T1WI and 3.2, 4.0, and 5.8 for PD-to achieve reduced scanning times in comparison with the original imaging sequence (SENSE T1WI, AF(t) 3.5; SENSE PD, AF(t) 2.0) using the 3-tesla system. Two neuroradiologists measured signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and used visual scoring systems to assess image quality. Acceptable imaging was defined as a visual score ≥ 2. Repeated measures analysis of variance and Cochran's Q test were performed. RESULTS: CS yielded better image quality and vessel delineation than SENSE in T1WI with AF(t) of 5.5, 6.8, and 9.7, and in PD with AF(t) of 5.8 (p 0.05). SNR and CNR in CS were higher than they were in SENSE, but lower than they were in the original images (p < 0.05). CS yielded higher proportions of acceptable imaging than SENSE (CS T1WI with AF(t) of 6.8 and PD with AF(t) of 5.8; p < 0.0167). CONCLUSION: CS is superior to SENSE, and may be a reliable acceleration method for vessel HR-MRI using AF(t) of 5.5 for T1WI, and 3.2 and 4.0 for PD.
Assuntos
Aceleração , Artérias , Voluntários Saudáveis , Imageamento por Ressonância Magnética , Métodos , Prótons , Razão Sinal-RuídoRESUMO
Neuroimaging plays a key role in assessing the detection of acute hemorrhage, diagnosis of infarct core, detection of steno-occlusive arteries, mismatch between infarct core and penumbra, and collateral circulation in patients with acute cerebral ischemic stroke. The recent announcement of randomized clinical trials that demonstrated the usefulness of intra-arterial mechanical thrombectomy and the guidelines of 2018 Guidelines for the Early Management of Patients with Acute Ischemic Stroke from American Heart Association/American Stroke Association led to a larger role of neuroimaging and required new neuroimaging strategy for acute cerebral ischemic stroke. In this review, we summarize the recommendation on neuroimaging from the 2018 Guidelines, and review pros and cons between CT and MR and fast scanned stroke MR. Based on the new guidelines and recent research, we discuss the appropriate neuroimaging strategy for acute cerebral ischemic stroke patients.
RESUMO
OBJECTIVE: To assess the technical performance of two-dimensional shear wave elastography (2D-SWE) for measuring liver stiffness. MATERIALS AND METHODS: The Ovid-MEDLINE and EMBASE databases were searched for studies reporting the technical performance of 2D-SWE, including concerns with technical failures, unreliable measurements, interobserver reliability, and/or intraobserver reliability, published until June 30, 2018. The pooled proportion of technical failure and unreliable measurements was calculated using meta-analytic pooling via the random-effects model and inverse variance method for calculating weights. Subgroup analyses were performed to explore potential causes of heterogeneity. The pooled intraclass correlation coefficients (ICCs) for interobserver and intraobserver reliability were calculated using the Hedges-Olkin method with Fisher's Z transformation of the correlation coefficient. RESULTS: The search yielded 34 articles. From 20 2D-SWE studies including 6196 patients, the pooled proportion of technical failure was 2.3% (95% confidence interval [CI], 1.3–3.9%). The pooled proportion of unreliable measurements from 20 studies including 6961 patients was 7.5% (95% CI, 4.7–11.7%). In the subgroup analyses, studies conducting more than three measurements showed fewer unreliable measurements than did those with three measurements or less, but no intergroup difference was found in technical failure. The pooled ICCs for interobserver reliability (from 10 studies including 517 patients) and intraobserver reliability (from 7 studies including 679 patients) were 0.87 (95% CI, 0.82–0.90) and 0.93 (95% CI, 0.89–0.95), respectively, suggesting good to excellent reliability. CONCLUSION: 2D-SWE shows good technical performance for assessing liver stiffness, with high technical success and reliability. Future studies should establish the quality criteria and optimal number of measurements.
Assuntos
Humanos , Técnicas de Imagem por Elasticidade , Fígado , Métodos , Características da População , Ultrassonografia , Pesos e MedidasRESUMO
OBJECTIVE: To develop algorithms using convolutional neural networks (CNNs) for automatic segmentation of acute ischemic lesions on diffusion-weighted imaging (DWI) and compare them with conventional algorithms, including a thresholding-based segmentation. MATERIALS AND METHODS: Between September 2005 and August 2015, 429 patients presenting with acute cerebral ischemia (training:validation:test set = 246:89:94) were retrospectively enrolled in this study, which was performed under Institutional Review Board approval. Ground truth segmentations for acute ischemic lesions on DWI were manually drawn under the consensus of two expert radiologists. CNN algorithms were developed using two-dimensional U-Net with squeeze-and-excitation blocks (U-Net) and a DenseNet with squeeze-and-excitation blocks (DenseNet) with squeeze-and-excitation operations for automatic segmentation of acute ischemic lesions on DWI. The CNN algorithms were compared with conventional algorithms based on DWI and the apparent diffusion coefficient (ADC) signal intensity. The performances of the algorithms were assessed using the Dice index with 5-fold cross-validation. The Dice indices were analyzed according to infarct volumes ( 100), time intervals to DWI, and DWI protocols. RESULTS: The CNN algorithms were significantly superior to conventional algorithms (p < 0.001). Dice indices for the CNN algorithms were 0.85 for U-Net and DenseNet and 0.86 for an ensemble of U-Net and DenseNet, while the indices were 0.58 for ADC-b1000 and b1000-ADC and 0.52 for the commercial ADC algorithm. The Dice indices for small and large lesions, respectively, were 0.81 and 0.88 with U-Net, 0.80 and 0.88 with DenseNet, and 0.82 and 0.89 with the ensemble of U-Net and DenseNet. The CNN algorithms showed significant differences in Dice indices according to infarct volumes (p < 0.001). CONCLUSION: The CNN algorithm for automatic segmentation of acute ischemic lesions on DWI achieved Dice indices greater than or equal to 0.85 and showed superior performance to conventional algorithms.
Assuntos
Humanos , Isquemia Encefálica , Consenso , Difusão , Comitês de Ética em Pesquisa , Estudos RetrospectivosRESUMO
OBJECTIVE: To identify potential imaging biomarkers of Alzheimer's disease by combining brain cortical thickness (CThk) and functional connectivity and to validate this model's diagnostic accuracy in a validation set. MATERIALS AND METHODS: Data from 98 subjects was retrospectively reviewed, including a study set (n = 63) and a validation set from the Alzheimer's Disease Neuroimaging Initiative (n = 35). From each subject, data for CThk and functional connectivity of the default mode network was extracted from structural T1-weighted and resting-state functional magnetic resonance imaging. Cortical regions with significant differences between patients and healthy controls in the correlation of CThk and functional connectivity were identified in the study set. The diagnostic accuracy of functional connectivity measures combined with CThk in the identified regions was evaluated against that in the medial temporal lobes using the validation set and application of a support vector machine. RESULTS: Group-wise differences in the correlation of CThk and default mode network functional connectivity were identified in the superior temporal (p < 0.001) and supramarginal gyrus (p = 0.007) of the left cerebral hemisphere. Default mode network functional connectivity combined with the CThk of those two regions were more accurate than that combined with the CThk of both medial temporal lobes (91.7% vs. 75%). CONCLUSION: Combining functional information with CThk of the superior temporal and supramarginal gyri in the left cerebral hemisphere improves diagnostic accuracy, making it a potential imaging biomarker for Alzheimer's disease.
Assuntos
Humanos , Doença de Alzheimer , Biomarcadores , Encéfalo , Cérebro , Imageamento por Ressonância Magnética , Neuroimagem , Lobo Parietal , Estudos Retrospectivos , Máquina de Vetores de Suporte , Lobo TemporalRESUMO
PURPOSE: To optimize the saturation time and maximizing the pH-weighted difference between the normal and ischemic brain regions, on 3-tesla amide proton transfer (APT) imaging using an in vivo rat model. MATERIALS AND METHODS: Three male Wistar rats underwent middle cerebral artery occlusion, and were examined in a 3-tesla magnetic resonance imaging (MRI) scanner. APT imaging acquisition was performed with 3-dimensional turbo spin-echo imaging, using a 32-channel head coil and 2-channel parallel radiofrequency transmission. An off-resonance radiofrequency pulse was applied with a Sinc-Gauss pulse at a B(1,rms) amplitude of 1.2 µT using a 2-channel parallel transmission. Saturation times of 3, 4, or 5 s were tested. The APT effect was quantified using the magnetization-transfer-ratio asymmetry at 3.5 ppm with respect to the water resonance (APT-weighted signal), and compared with the normal and ischemic regions. The result was then applied to an acute stroke patient to evaluate feasibility. RESULTS: Visual detection of ischemic regions was achieved with the 3-, 4-, and 5-s protocols. Among the different saturation times at 1.2 µT power, 4 s showed the maximum difference between the ischemic and normal regions (-0.95%, P = 0.029). The APTw signal difference for 3 and 5 s was -0.9% and -0.7%, respectively. The 4-s saturation time protocol also successfully depicted the pH-weighted differences in an acute stroke patient. CONCLUSION: For 3-tesla turbo spin-echo APT imaging, the maximal pH-weighted difference achieved when using the 1.2 µT power, was with the 4 s saturation time. This protocol will be helpful to depict pH-weighted difference in stroke patients in clinical settings.
Assuntos
Animais , Humanos , Masculino , Ratos , Encéfalo , Cabeça , Infarto da Artéria Cerebral Média , Imageamento por Ressonância Magnética , Modelos Animais , Prótons , Ratos Wistar , Acidente Vascular Cerebral , ÁguaRESUMO
PURPOSE: To optimize the saturation time and maximizing the pH-weighted difference between the normal and ischemic brain regions, on 3-tesla amide proton transfer (APT) imaging using an in vivo rat model. MATERIALS AND METHODS: Three male Wistar rats underwent middle cerebral artery occlusion, and were examined in a 3-tesla magnetic resonance imaging (MRI) scanner. APT imaging acquisition was performed with 3-dimensional turbo spin-echo imaging, using a 32-channel head coil and 2-channel parallel radiofrequency transmission. An off-resonance radiofrequency pulse was applied with a Sinc-Gauss pulse at a B(1,rms) amplitude of 1.2 µT using a 2-channel parallel transmission. Saturation times of 3, 4, or 5 s were tested. The APT effect was quantified using the magnetization-transfer-ratio asymmetry at 3.5 ppm with respect to the water resonance (APT-weighted signal), and compared with the normal and ischemic regions. The result was then applied to an acute stroke patient to evaluate feasibility. RESULTS: Visual detection of ischemic regions was achieved with the 3-, 4-, and 5-s protocols. Among the different saturation times at 1.2 µT power, 4 s showed the maximum difference between the ischemic and normal regions (-0.95%, P = 0.029). The APTw signal difference for 3 and 5 s was -0.9% and -0.7%, respectively. The 4-s saturation time protocol also successfully depicted the pH-weighted differences in an acute stroke patient. CONCLUSION: For 3-tesla turbo spin-echo APT imaging, the maximal pH-weighted difference achieved when using the 1.2 µT power, was with the 4 s saturation time. This protocol will be helpful to depict pH-weighted difference in stroke patients in clinical settings.
Assuntos
Animais , Humanos , Masculino , Ratos , Encéfalo , Cabeça , Infarto da Artéria Cerebral Média , Imageamento por Ressonância Magnética , Modelos Animais , Prótons , Ratos Wistar , Acidente Vascular Cerebral , ÁguaRESUMO
BACKGROUND AND PURPOSE: Decreasing the time delay for thrombolysis, including intravenous thrombolysis (IVT) with tissue plasminogen activator and intra-arterial thrombectomy (IAT), is critical for decreasing the morbidity and mortality of patients experiencing acute stroke. We aimed to decrease the in-hospital delay for both IVT and IAT through a multidisciplinary approach that is feasible 24 h/day. METHODS: We implemented the Stroke Alert Team (SAT) on May 2, 2016, which introduced hospital-initiated ambulance prenotification and reorganized in-hospital processes. We compared the patient characteristics, time for each step of the evaluation and thrombolysis, thrombolysis rate, and post-thrombolysis intracranial hemorrhage from January 2014 to August 2016. RESULTS: A total of 245 patients received thrombolysis (198 before SAT; 47 after SAT). The median door-to-CT, door-to-MRI, and door-to-laboratory times decreased to 13 min, 37.5 min, and 8 min, respectively, after SAT implementation (P<0.001). The median door-to-IVT time decreased from 46 min (interquartile range [IQR] 36–57 min) to 20.5 min (IQR 15.8–32.5 min; P<0.001). The median door-to-IAT time decreased from 156 min (IQR 124.5–212.5 min) to 86.5 min (IQR 67.5–102.3 min; P<0.001). The thrombolysis rate increased from 9.8% (198/2,012) to 15.8% (47/297; P=0.002), and the post-thrombolysis radiological intracranial hemorrhage rate decreased from 12.6% (25/198) to 2.1% (1/47; P=0.035). CONCLUSIONS: SAT significantly decreased the in-hospital delay for thrombolysis, increased thrombolysis rate, and decreased post-thrombolysis intracranial hemorrhage. Time benefits of SAT were observed for both IVT and IAT and during office hours and after-hours.
Assuntos
Humanos , Ambulâncias , Infarto Cerebral , Hemorragias Intracranianas , Mortalidade , Acidente Vascular Cerebral , Trombectomia , Terapia Trombolítica , Ativador de Plasminogênio TecidualRESUMO
OBJECTIVE: The management of patients with ruptured cerebral aneurysms and severe vasospasm is subject to considerable controversy. We intended to describe herein an endovascular technique for the simultaneous treatment of aneurysms and vasospasm. MATERIALS AND METHODS: A series of 11 patients undergoing simultaneous endovascular treatment of ruptured aneurysms and vasospasm were reviewed. After placement of a guiding catheter within the proximal internal carotid artery for coil embolization, an infusion line of nimodipine was wired to one hub, and of a microcatheter was advanced through another hub (to select and deliver detachable coils). Nimodipine was then infused continuously during the coil embolization. RESULTS: This technique was applied to 11 ruptured aneurysms accompanied by vasospasm (anterior communicating artery, 6 patients; internal carotid artery, 2 patients; posterior communicating and middle cerebral arteries, 1 patient each). Aneurysmal occlusion by coils and nimodipine-induced angioplasty were simultaneously achieved, resulting in excellent outcomes for all patients, and there were no procedure-related complications. Eight patients required repeated nimodipine infusions. CONCLUSION: Our small series of patients suggests that the simultaneous endovascular management of ruptured cerebral aneurysms and vasospasm is a viable approach in patients presenting with subarachnoid hemorrhage and severe vasospasm.
Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Aneurisma Roto/terapia , Artéria Carótida Interna/diagnóstico por imagem , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano/terapia , Angiografia por Ressonância Magnética , Nimodipina/uso terapêutico , Estudos Retrospectivos , Vasodilatadores/uso terapêutico , Vasoespasmo Intracraniano/terapiaRESUMO
Two angiographic instances of anomalous external carotid artery (ECA) and internal carotid artery (ICA) anastomosis are described, each occurring at the C2-3 level and bearing remnants of proximal ICA. The ICA remnant of one patient (identifiable immediately upon bifurcation of the common carotid artery) was hypoplastic, and that of the other patient was an occluded arterial stump. These features are not typical of non-bifurcating ICA. The occipital artery originated from an anomalous connection in one instance and from the main trunk of the ECA (just past the ECA-ICA connection) in the other.
Assuntos
Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Arteriopatias Oclusivas/diagnóstico por imagem , Artéria Carótida Externa/anormalidades , Artéria Carótida Interna/anormalidades , Angiografia Cerebral , Aneurisma Intracraniano/diagnóstico por imagemRESUMO
Vessel wall imaging can depict the morphologies of atherosclerotic plaques, arterial walls, and surrounding structures in the intracranial and cervical carotid arteries beyond the simple luminal changes that can be observed with traditional luminal evaluation. Differentiating vulnerable from stable plaques and characterizing atherosclerotic plaques are vital parts of the early diagnosis, prevention, and treatment of stroke and the neurological adverse effects of atherosclerosis. Various techniques for vessel wall imaging have been developed and introduced to differentiate and analyze atherosclerotic plaques in the cervical carotid artery. High-resolution magnetic resonance imaging (HR-MRI) is the most important and popular vessel wall imaging technique for directly evaluating the vascular wall and intracranial artery disease. Intracranial artery atherosclerosis, dissection, moyamoya disease, vasculitis, and reversible cerebral vasoconstriction syndrome can also be diagnosed and differentiated by using HR-MRI. Here, we review the radiologic features of intracranial artery disease and cervical carotid artery atherosclerosis on HR-MRI and various other vessel wall imaging techniques (e.g., ultrasound, computed tomography, magnetic resonance, and positron emission tomography-computed tomography).
Assuntos
Artérias , Aterosclerose , Artérias Carótidas , Diagnóstico Precoce , Elétrons , Imageamento por Ressonância Magnética , Doença de Moyamoya , Fenobarbital , Placa Aterosclerótica , Acidente Vascular Cerebral , Ultrassonografia , Vasculite , VasoconstriçãoRESUMO
OBJECTIVE: To assess the feasibility of computed tomography (CT) lymphography using ethiodized oil for sentinel node mapping in experimentally induced VX2 carcinoma in the rabbit thigh. MATERIALS AND METHODS: This experiment received approval from the institutional animal use and care administrative advisory committee. Twenty-three rabbits with VX2 carcinoma in the thigh underwent CT before and after (1 hour, 2 hour) peritumoral injection of 2 mL ethiodized oil. After the CT examination, sentinel nodes were identified by peritumoral injection of methylene blue and subsequently removed. The retrieved sentinel and non-sentinel lymph nodes were investigated with radiographic and pathologic examinations. Based on the comparison of CT findings with those of radiographic and pathologic examinations, the diagnostic performance of CT for sentinel node identification was assessed. RESULTS: All 23 rabbits showed 53 ethiodized oil retention nodes on post-injection CT and specimen radiography, and 52 methylene blue-stained nodes at the right femoroiliac area. Of the 52 blue-stained sentinel nodes, 50 nodes demonstrated ethiodized oil retention. Thus, the sentinel node detection rate of CT was 96% (50 of 52). On pathologic examination, 28 sentinel nodes in 17 rabbits (nodes/rabbit, mean +/- standard deviation, 1.7 +/- 0.6) harbored metastasis. Twenty seven of the 28 metastatic sentinel nodes were found to have ethiodized oil retention. CONCLUSION: Computed tomography lymphography using ethiodized oil may be feasible for sentinel node mapping in experimentally induced VX2 carcinoma in the rabbit thigh.
Assuntos
Animais , Feminino , Coelhos , Carcinoma/patologia , Meios de Contraste , Óleo Etiodado , Estudos de Viabilidade , Injeções , Excisão de Linfonodo/métodos , Linfonodos/patologia , Metástase Linfática/diagnóstico por imagem , Linfografia/métodos , Coxa da Perna , Tomografia Computadorizada por Raios X/métodosRESUMO
OBJECTIVE: To determine the optimal iodine concentration of contrast media for kidney multidetector computed tomography (MDCT) by comparing the degree of renal parenchymal enhancement and the severity of the renal streak artifact with contrast media of different iodine concentrations. MATERIALS AND METHODS: A 16-row MDCT was performed in 15 sedated rabbits by injection of 2 mL contrast media/kg body weight at a rate of 0.3 mL/sec. Monomeric nonionic contrast media of 250, 300, and 370 mg iodine/mL were injected at 1-week intervals. Mean attenuation values were measured in each renal structure with attenuation differences among the structures. The artifact was evaluated by CT window width/level and three grading methods. The values were compared with iodine concentrations. RESULTS: The 370 mg iodine/mL concentration showed significantly higher cortical enhancement than 250 mg iodine/mL in all phases (p < 0.05). There was however no significant difference in the degree of enhancement between the 300 mg iodine/mL and 370 mg iodine/mL concentrations in all phases. There is a significant difference in attenuation for the cortex-outer medulla between 250 mg iodine/mL and 300 mg iodine/mL (p < 0.05). The artifact was more severe with a medium of 370 mg iodine/mL than with 250 mg iodine/mL by all grading methods (p < 0.05). CONCLUSION: The 300 mg iodine/mL is considered to be the most appropriate iodine concentration in an aspect of the enhancement and artifact on a kidney MDCT scan.