Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Adicionar filtros








Intervalo de ano
1.
Indian Heart J ; 2008 May-Jun; 60(3): 228-32
Artigo em Inglês | IMSEAR | ID: sea-3738

RESUMO

OBJECTIVE: To evaluate the performance of a biodegradable polymer based rapamycin-eluting coronary stent in a porcine model and demonstrate its safety and efficacy in the treatment of patients with de novo coronary stenosis. BACKGROUND: The indefinite presence of the polymer after the implantation of drug-eluting stents may initiate and sustain inflammation and contribute to the occurrence of late complications. METHODS: Seven study stents and 5 polymer-coated (control) stents were implanted in porcine carotid arteries. Histomorphometric analysis was performed 8 weeks after stent implantation. After establishing the safety of the stent in the animal model, a single-center, non-randomized study in patients with de novo coronary artery lesions was performed. Forty-nine stents were implanted in 43 patients. The 6-month clinical follow-up was 91% (39/43) and angiographic follow-up was 67% (29/43). The primary safety endpoint was the occurrence of 30-day major adverse cardiovascular events (MACE) and the principal efficacy endpoint was the 6-month angiographic late loss and binary restenosis rate. RESULTS: In the porcine model, the study stent showed acceptably low injury, inflammation and fibrin scores. There was a quantitative reduction in neointimal hyperplasia which was not statistically different from the control stent. However, in the first-in-man evaluation, there was significant suppression of intimal growth as evidenced by an angiographic late loss of 0.28 +/- 0.45 mm at 6 months. The restenosis rate was 10.3% (3/297). There was no death, stent thrombosis or myocardial infarction at 30 days or at 6 months. The 6-month target lesion revascularization rate was 3.47 percent; (1/29). CONCLUSION: This preclinical and early clinical experience demonstrates the safety and efficacy of a novel biodegradable polymer-based rapamycin-eluting coronary stent.


Assuntos
Implantes Absorvíveis , Animais , Aspirina/uso terapêutico , Reestenose Coronária/tratamento farmacológico , Trombose Coronária/etiologia , Stents Farmacológicos/efeitos adversos , Humanos , Imunossupressores/efeitos adversos , Índia , Inflamação/prevenção & controle , Modelos Animais , Inibidores da Agregação Plaquetária/uso terapêutico , Polímeros , Fatores de Risco , Sirolimo/efeitos adversos , Ticlopidina/análogos & derivados , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA