Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Biomedical Engineering ; (6): 697-701, 2015.
Artigo em Chinês | WPRIM | ID: wpr-359582

RESUMO

As one of the important indexes for the diagnosis and treatment of cardiovascular diseases, cardiac output can reflect the state of cardiovascular system timely, and can play a guiding role in the treatment of related diseases. In recent years detection technology of cardiac output has caused great attention, especially minimally invasive and non-invasive methods. In this paper, the principle of non-invasive detection methods and their recent developments are described, and various detection methods are also analyzed.


Assuntos
Humanos , Débito Cardíaco , Doenças Cardiovasculares , Diagnóstico , Fenômenos Fisiológicos Cardiovasculares
2.
Journal of Biomedical Engineering ; (6): 684-691, 2013.
Artigo em Chinês | WPRIM | ID: wpr-352185

RESUMO

The principle of ambulatory cardiac output (CO) measuring technique is introduced in this paper. Experimental studies about the applicability of the two-compartment coaxial cylindrical model for ambulatory measurement of cardiac output with spot-electrodes have been carried out with using our newly-developed multi-channel impedance mapping system. The key factors using a spot-electrode array instead of a conventional band-electrode array for non-invasive CO) measurement are elaborated. The variations of the electric impedance pulsatile component (deltaZ waveform) and the two kinds of typical modes of deltaZ distributions measured by six electrodes on the midsternal (midian) line from the medial portion at the level of clavicle to the portion above the xiphisternum are discussed. The applicability of the two-compartment coaxial cylindrical model for ambulatory measurement of CO with spot-electrodes is analyzed. Synthesizing the deltaZ distributions and their typical changing models on the midsternal (midian) line during blood inflowing into aorta is the optimal positions of a pair of spot-electrodes for voltage pick-up at the level of clavicle for the upper electrode and the position at the level of nipple for the lower electrode when spot-electrode is being used to measure non-invasive CO.


Assuntos
Humanos , Engenharia Biomédica , Débito Cardíaco , Fisiologia , Cardiografia de Impedância , Métodos , Eletrocardiografia Ambulatorial , Métodos , Eletrodos , Desenho de Equipamento , Coração , Fisiologia , Modelos Cardiovasculares , Tórax
3.
Chinese Journal of Medical Instrumentation ; (6): 321-325, 2012.
Artigo em Chinês | WPRIM | ID: wpr-342938

RESUMO

A small experimental system is constructed with working principle of continuous blood pressure monitoring based on the volume compensation method. The preliminary experimental results show that the system can collect blood pressure signals at the radial artery effectively. The digital PID algorithm can track the variation of blood pressure. And the accuracy of continuous blood pressure detecting achieve the level of same kind of product.


Assuntos
Humanos , Algoritmos , Determinação da Pressão Arterial , Métodos , Desenho de Equipamento , Processamento de Sinais Assistido por Computador
4.
Journal of Biomedical Engineering ; (6): 32-57, 2011.
Artigo em Chinês | WPRIM | ID: wpr-260854

RESUMO

Principle of ambulatory cardiac output (CO) measuring technique is introduced in this paper. A lot of experimental studies of the current distribution on the thorax under the condition that the current injection electrodes were adhered to different positions were carried out by using a developed multi-channel impedance mapping system. The static impedance contour maps (Zo-map) and its pulsatile component contour maps (deltaZ-map) under different measuring conditions were analyzed, and the applicability of a two-compartment coaxial cylindrical model using a spot-electrode array instead of the conventional band-electrode array for ambulatory CO measurement, as well as the optimal spot-electrode array, were discussed. Based on the experimental results and the daily use of the ambulatory CO measuring technique, the optimal spot-electrode array meeting the condition of the two-compartment coaxial cylindrical model was determined as that a pair of spot-electrodes for current injection was located on the positions behind the ears and on the right lower abdomen, and a pair of spot-electrodes for voltage pick-up places on the medial portion at the level of clavicle and on the portion above the xiphisternum.


Assuntos
Humanos , Débito Cardíaco , Fisiologia , Cardiografia de Impedância , Métodos , Impedância Elétrica , Eletrodos , Desenho de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA