Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Arq. bras. cardiol ; 118(4): 680-691, Apr. 2022. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1374350

RESUMO

Resumo Fundamento A espirometria é subutilizada na insuficiência cardíaca (IC) e não está claro o grau de associação de cada defeito com a capacidade de exercício e com o prognóstico desses pacientes. Objetivo Determinar a relação da %CVF prevista (ppCVF) e do VEF1/CVF contínuos com: 1) pressão inspiratória máxima (PImáx), fração de ejeção do ventrículo esquerdo (FEVE) e desempenho ao exercício; e 2) prognóstico, para o desfecho composto de morte cardiovascular, transplante cardíaco ou implante de dispositivo de assistência ventricular. Métodos Coorte de 111 participantes com IC (estágios AHA C/D) sem pneumopatia; foram submetidos a espirometria, manovacuometria e teste cardiopulmonar máximo. As magnitudes de associação foram verificadas por regressões lineares e de Cox (HR; IC 95%), ajustadas para idade/sexo, e p <0,05 foi considerado significativo. Resultados Com idade média 57±12 anos, 60% eram homens, 64% em NYHAIII. A cada aumento de 10% no VEF1/CVF [β 7% (IC 95%: 3-10)] e no ppCVF [4% (2-6)], foi associado à reserva ventilatória (VRes); no entanto, apenas o ppCVF associado à PImáx [3,8cmH2O (0,3-7,3)], à fração de ejeção do ventrículo esquerdo (FEVE) [2,1% (0,5-3,8)] e ao VO2 pico [0,5mL/kg/min (0,1-1,0)], considerando idade/sexo. Em 2,2 anos (média), ocorreram 22 eventos; tanto FEV1/FVC (HR 1,44; IC 95%: 0,97-2,13) quanto ppCVF (HR 1,13; 0,89-1,43) não foram associados ao desfecho. Apenas no subgrupo FEVE ≤50% (n=87, 20 eventos), VEF1/CVF (HR 1,50; 1,01-2,23), mas não ppCVF, foi associado a risco. Conclusão Na IC crônica, ppCVF reduzido associou-se a menor PImáx, FEVE, VRes e VO2 pico, mas não distinguiu pior prognóstico em 2,2 anos de acompanhamento. Entretanto, VEF1/CVF associou-se apenas com VRes, e, em participantes com FEVE ≤50%, o VEF1/CVF reduzido mostrou pior prognóstico proporcional. Portanto, VEF1/CVF e ppFVC contribuem para melhor fenotipagem de pacientes com IC.


Abstract Background Spirometry is underused in heart failure (HF) and the extent to which each defect associates with exercise capacity and prognosis is unclear. Objective To determine the distinct relationship of continuous %predicted FVC (ppFVC) and FEV1/FVC with: 1) maximal inspiratory pressure (MIP), left ventricular ejection fraction (LVEF), exercise performance; and 2) prognosis for the composite of cardiovascular death, heart transplantation or left ventricular assist device implant. Methods A cohort of 111 HF participants (AHA stages C/D) without diagnosed pneumopathy, spirometry, manovacuometry and maximum cardiopulmonary test. The association magnitudes were verified by linear and Cox (HR; 95% CI) regressions, age/sex adjusted. A p<0.05 was considered significant. Results Age was 57±12 years, 60% men, 64% in NYHA III. Every 10%-point increase in FEV1/FVC [β 7% (95% CI: 3-10)] and ppFVC [4% (2-6)] associated with ventilatory reserve (VRes), however only ppFVC associated with MIP [3.8 cmH2O (0.3-7.3)], LVEF [2.1% (0.5-3.8)] and VO2peak [0.5 mL/kg/min (0.1-1.0)], accounting for age/sex. In 2.2 years (mean), 22 events occurred, and neither FEV1/FVC (HR 1.44; 95% CI: 0.97-2.13) nor ppFVC (HR 1.13; 0.89-1.43) was significantly associated with the outcome. Only in the LVEF ≤50% subgroup (n=87, 20 events), FEV1/FVC (HR 1.50; 1.01-2.23), but not ppFVC, was associated with greater risk. Conclusions In chronic HF, reduced ppFVC associated with lower MIP, LVEF, VRes and VO2peak, but no distinct poorer prognosis over 2.2 years of follow-up. Distinctively, FEV1/FVC was associated only with VRes, and, in participants with LVEF ≤50%, FEV1/FVC reduction proportionally worsened prognosis. Therefore, FEV1/FVC and ppFVC add supplementary information regarding HF phenotyping.

2.
J. bras. pneumol ; 48(4): e20210511, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1405415

RESUMO

ABSTRACT Objective: To establish normative values and a reference equation for the number of steps climbed during the six-minute step test (6MST) in healthy adults, and to assess the reliability of the test and of the equation. Methods: This was a multicenter cross-sectional study involving 468 healthy volunteers (age range: 18-79 years) recruited from the general community in six research laboratories across different regions of Brazil, which is a country with continental dimensions. The 6MST was performed twice (30-min interval), and clinical, demographic, and functional variables were evaluated. An independent sample of 24 volunteers was evaluated to test the reference equation a posteriori. Results: The number of steps had excellent test-retest reliability (intraclass correlation coefficient = 0.96 [95%CI: 0.95-0.97]), and the mean number of steps was 175 ± 45, the number being 14% greater in males than in females. The best performance on the test was correlated with age (r = −0.60), sex (r = 0.28), weight (r = 0.13), height (r = 0.41), BMI (r = −0.22), waist circumference (r = −0.22), thigh circumference (r = 0.15), FVC (r = 0.54), and physical activity level (r = 0.17; p < 0.05 for all). In the regression analysis, age, sex, height, and weight explained 42% of the variability of the 6MST. Normative values were established for the 6MST according to age and sex. There was no difference between the 6MST values from the independent sample and its predicted values (157 ± 29 steps vs. 161 ± 25 steps; p = 0.47; 97% of predicted values). Conclusions: The normative values and the reference equation for the 6MST in this study seem adequate to accurately predict the physical functional performance in adults in Brazil.


RESUMO Objetivo: Estabelecer valores normativos e uma equação de referência para o número de degraus subidos no teste do degrau de seis minutos (TD6) em adultos saudáveis, bem como avaliar a confiabilidade do teste e da equação. Métodos: Estudo transversal multicêntrico com 468 voluntários saudáveis (faixa etária: 18-79 anos) recrutados na comunidade geral em seis laboratórios de pesquisa em diferentes regiões do Brasil, um país de dimensões continentais. O TD6 foi realizado duas vezes (com 30 min de intervalo entre uma e outra), e foram avaliadas variáveis clínicas, demográficas e funcionais. Uma amostra independente composta por 24 voluntários foi avaliada para testar a equação de referência a posteriori. Resultados: O número de degraus subidos apresentou excelente confiabilidade teste-reteste [coeficiente de correlação intraclasse = 0,96 (IC95%: 0,95-0,97)], e a média de degraus subidos foi de 175 ± 45, sendo 14% maior no sexo masculino. O melhor desempenho no teste correlacionou-se com as seguintes variáveis: idade (r = −0,60), sexo (r = 0,28), peso (r = 0,13), estatura (r = 0,41), IMC (r = −0,22), circunferência da cintura (r = −0,22), circunferência da coxa (r = 0,15), CVF (r = 0,54) e nível de atividade física (r = 0,17; p < 0,05 para todos). Na análise de regressão, idade, sexo, estatura e peso explicaram 42% da variabilidade do TD6. Foram estabelecidos valores normativos para o TD6 de acordo com a idade e o sexo. Não houve diferença entre os valores do TD6 na amostra independente e os valores previstos (157 ± 29 vs. 161 ± 25 degraus subidos; p = 0,47; 97% dos valores previstos). Conclusões: Os valores normativos e a equação de referência para o TD6 neste estudo parecem adequados para predizer com precisão o desempenho físico funcional em adultos no Brasil.

3.
Fisioter. mov ; 22(3): 419-426, jul.-set. 2009. tab
Artigo em Português | LILACS | ID: lil-541096

RESUMO

A aplicação da pressão positiva expiratória nas vias aéreas (EPAP) é um método terapêutico usado para reexpansão pulmionar. A avaliação das variáveis hemodinâmicas e vewntilatórias, podem apresentar alterações quando os indivíduos são submetidos a diferentes níveis de pressões intratorácicas. Objetivo: Analisar as variáveis cardiorrespiratórias, em indivíduos jovens sadios, submetidos a diferentes níveis de EPAP. Casuística e método: Estudo prospectivo transversal com 14 voluntários jovens sadios e ativos. Os voluntários foram posicionados sentados, e fixaram a máscara facial de forma a evitar fuga aérea, a máscara foi conectada ao sensor de fluxo do monitor de perfil respiratório tracer 5 e acoplada à válvula Spring Loaded. Cada voluntário realizou seis incursões respiratórias sendo utilizado o início da quarta resistência do sistema e trabalho ventilatório foram analisadas ajustando o EPAP em: 5, 10, 15 e 20 cmH2O, com pausa de 1 minuto entre cada ajuste pressônico. Para análise estatística utilizou-se o teste Kruskal-Wallis e Mann-Whitney, Wilcoxon e o coeficiente para correlação de Spearman. Nível de significância p menor que 0,05. Resultados: A idade média do grupo estudado foi de 22+-3 anos e obteve-se diferença estatisticamente significante nas variáveisrespiratórias e hemodinãmicas, bem como na sensação de dispnéia e vertigem confrome o aumento progressivo dos níveis de pressões intratorácicas utilizadas. Conclusão: A aplicação de diferentes níveis de EPAP pode gerar alterações na condição hemodinâmica e mecânica ventilatória de indivíduos adultos jovens sadios.


Assuntos
Humanos , Masculino , Feminino , Adulto , Hemodinâmica , Modalidades de Fisioterapia , Respiração com Pressão Positiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA