Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Braz. J. Vet. Res. Anim. Sci. (Online) ; 57(3): e166205, 2020. tab, graf
Artigo em Inglês | VETINDEX, LILACS | ID: biblio-1122181

RESUMO

In freshwater fish with external fertilization, sperm sampling can be contaminated with urine, which triggers motility and gives rise to decreased fertilization success. The maintenance of freshwater fish in hyperosmotic conditions may reduce urine production and improve sperm quality. Thus, the aim of this work was to verify if acute exposure to various NaCl concentrations improves sperm quality in the yellowtail tetra Astyanax altiparanae. Spermiation was induced using a single dose of carp pituitary gland (5 mg kg-1) and the males were maintained at various NaCl concentrations: NaCl 0.00% (control), NaCl 0.45% (hypoosmotic), NaCl 0.9% (isosmotic) and NaCl 1.0% (hyperosmotic) for 6 h at 26 °C. Sperm was collected and verified for activation by urine and motility traits. At 0.00%, 0.45%, and 0.90%, the sperm was motile just after sampling, indicating activation by urine. Surprisingly, at hyperosmotic conditions, no activation was observed. Other sperm and motility parameters did not show any statistical differences, including sperm viability (P = 0.7083), concentration (P = 0.9030), total motility (P = 0.6149), VCL (curvilinear velocity; P = 0.1216), VAP (average path velocity; P = 0.1231) and VSL (straight-line velocity; P = 0.1340). Our results indicate that acute maintenance at hyperosmotic conditions eliminates sperm activation by urine and maintains sperm quality. Such a new procedure is interesting for both basic and applied sciences, including reproductive practice in fish.(AU)


Em peixes de água doce com fertilização externa, a amostragem de espermatozoides pode ser contaminada pela urina, o que desencadeia motilidade e gera menor sucesso na fertilização. A manutenção de peixes de água doce em condições hiperosmóticas pode reduzir a produção de urina e melhorar a qualidade do esperma. Assim, o presente trabalho foi delineado para verificar se a exposição aguda a várias concentrações de NaCl melhora a qualidade do esperma no tetra-amarelo Astyanax altiparanae. A espermiação foi induzida usando uma dose única de hipófise da carpa (5 mg kg-1) e os machos foram mantidos em várias concentrações de NaCl: NaCl 0,00% (controle), NaCl 0,45% (hipoosmótico), NaCl 0,9% (isosmótico) e NaCl 1,0% (hiperosmótico) por seis horas a 26 °C. O esperma foi colhido e verificado quanto à ativação por urina e traços de motilidade. Em 0,00%, 0,45%, 0,90% os espermatozóides eram móveis logo após a amostragem, indicando ativação pela urina. Surpreendentemente, em condições hiperosmóticas, nenhuma ativação foi observada. Outros parâmetros espermáticos e de motilidade não mostraram diferenças estatísticas, incluindo viabilidade espermática (P = 0,7083), concentração (P = 0,9030), motilidade total (P = 0,6149), VCL (Velocidade Curvilinear; P = 0,1216), VMD (Velocidade Média de Deslocamento; P = 0,1230) e VLR (Velocidade em linha Reta; P = 0,1340). Nossos resultados indicam que a manutenção aguda em condições hiperosmóticas elimina a ativação do esperma pela urina e mantém a qualidade do esperma. Esse novo procedimento é interessante para as ciências básicas e aplicadas, incluindo a prática reprodutiva em peixes.(AU)


Assuntos
Animais , Osmose , Salinidade , Análise do Sêmen/métodos , Análise do Sêmen/veterinária , Characidae/fisiologia , Motilidade dos Espermatozoides
2.
J. bras. patol. med. lab ; 50(2): 100-104, Mar-Apr/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-712706

RESUMO

Introduction: Efficient laboratory services are the basis of modern health systems. Scientific innovations have contributed to substantial improvements in the laboratory environment, but errors still persist. These errors are classified as pre-analytical, analytical and post-analytical, according to the time of occurrence. Objective: To evaluate the frequency of pre-analytical errors in the clinical laboratory service of a military hospital. Methods: A total of 329,582 tests were performed in the clinical laboratory of Hospital Naval Marcílio Dias (HNMD) from August to October 2012, and pre-analytical errors were documented. Results: The most frequent cause of the observed pre-analytical errors was hemolysis (27.54%), followed by samples not received (25.43%) and insufficient sample volume (18.49%). The samples from the Integrated Home Care Service (SIAD) showed the highest frequency of errors (3.38%), followed by those from the inpatient (0.76%) and the outpatient departments (0.21%). Conclusion: Our study demonstrates the importance of managing laboratory pre-analytical quality in order to ensure service excellence...


Introdução: Serviços laboratoriais efetivos são a base dos sistemas de saúde modernos. Inovações científicas têm contribuído para melhorias substanciais no meio laboratorial, mas os erros ainda persistem. Esses erros são classificados como pré-analíticos, analíticos e pós-analíticos, dependendo do momento de sua ocorrência. Objetivo: Avaliar a frequência de erros pré-analíticos ocorridos no serviço de análises clínicas de um hospital militar. Métodos: Um total de 329.582 exames foram realizados no laboratório de análises clínicas do Hospital Naval Marcílio Dias no período de agosto a outubro de 2012, e os erros pré-analíticos documentados. Resultados: Os erros pré-analíticos mais observados foram decorrentes da hemólise (27,54%), seguidos de material não recebido (25,43%) e amostra insuficiente (18,49%). As amostras oriundas do Serviço Integrado de Atendimento Domiciliar (SIAD) foram as que apresentaram a maior frequência de erros (3,38%), seguidas pelo setor de pacientes internos (0,76%) e ambulatoriais (0,21%), respectivamente. Conclusão: Nosso estudo demonstra a importância da gestão da fase pré-analítica na garantia da qualidade laboratorial, de maneira a assegurar um serviço de excelência...


Assuntos
Humanos , Gestão da Qualidade Total , Indicadores de Serviços , Laboratórios Hospitalares/normas , Erros de Diagnóstico/estatística & dados numéricos , Laboratórios Hospitalares/organização & administração , Controle de Qualidade
3.
Rev. bras. anestesiol ; 50(1): 8-13, jan.-fev. 2000. tab
Artigo em Português | LILACS | ID: lil-254995

RESUMO

Justificativa e objetivos - a morfina ou o fentanil têm sido utilizados para analgesia pós-operatória, por via peridural, de forma contínua com bomba de infusäo, permitindo também que a analgesia seja controlada pelo paciente (ACP). O objetivo deste estudo foi avaliar a qualidade da analgesia, o consumo de opióides e os efeitos colaterais do emprego de infusäo contínua e de ACP com morfina ou fentanil, no pós-operatório de pacientes submetidos a reconstruçäo de ligamento do joelho, sob anestesia peridural com bupivacaína associada ao fentanil. Método - participaram do estudo 42 pacientes com idade entre 16 e 50 anos, estado físico ASA I e II, divididos aleatoriamente em dois grupos de 21: Grupo M (Morfina) e Grupo F (Fentanil). Todos os pacientes foram submetidos a anestesia peridural com bupivacaína a 0,5 por cento (100 mg) associada a fentanil (100 µg). Ao final da cirurgia os pacientes receberam morfina (Grupo M) ou fentanil (Grupo F) em regime de ACP, por via peridural, através de bomba de infusäo. No Grupo M foi utilizada soluçäo fisiológica (93 ml) contendo morfina 2 mg (2ml) e bupivacaína 0,5 por cento (5 ml). No Grupo F foi utilizada soluçäo fisiológica (85 ml) contendo fentanil 500 µg (10 ml), bupivacaína (5 ml a 5 por cento) sem adrenalina. Para os dois grupos foi programado inicialmente infusäo contínua de 4 ml.h elevado a menos um, com doses de 2 ml em bolus liberado pelo paciente num intervalo de 30 minutos. Foram comparados os seguintes parâmetros: dor; número de bolus acionados; consumo de opióides; bloqueio motor; sedaçäo e efeitos colaterais (prurido, náuseas, vômitos e retençäo urinária). Resultados - Näo houve necessidade de suplementaçäo anestésica no per-operatório. A maioria dos pacientes (85,7 por cento) obteve excelente grau de analgesia pós-operatória (EAV 0a 2), sem diferença significativa entre os grupos. A média de bolus acionados näo diferiu nos dois grupos. O consumo médio de morfina foi de 1,663 ñ 0,384 mg sendo o de fentanil de 0,435 ñ 0,083 mg. Näo houve bloqueio motor após a instituiçäo da ACP. A incidência de sedaçäo e de outros efeitos colaterais foi também significativamente maior no grupo da morfina


Assuntos
Humanos , Adolescente , Adulto , Pessoa de Meia-Idade , Analgesia Controlada pelo Paciente , Artroscopia , Fentanila , Joelho , Ligamentos/cirurgia , Morfina , Período Pós-Operatório , Anestesia por Condução , Anestesia Epidural
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA