Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Acta cir. bras ; 25(4): 337-341, July-Aug. 2010. ilus
Artigo em Inglês | LILACS | ID: lil-553240

RESUMO

PURPOSE: To verify if the composit poli (2-hydroxyethyl methacrylate)-PolyHEMA/polypropylene mesh implanted in the female rat's abdominal wall could be suitable for the prevention of peritoneal adhesions, and for the evaluation of the tecidual response produced by this biomaterial. METHODS: Polypropylene meshes (Group PP, n=20) and polypropylene meshes coated with a layer of poli (2-hydroxyethyl methacrylate)-PolyHEMA (Group PH, n=20) were implanted on the abdominal wall of Wistar female rats. Ten animals from each group were submitted to euthanasia at 15 and 30 days of the postoperative period. RESULTS: The animals from the group PP presented visceral adhesions on the mesh surface, which was not observed in the ones from group PH. At the histopathological examination foreign body response was observed in both groups, whilst there was a greater intensity of inflammatory response in group PH on both moments. CONCLUSION: The poli (2-hydroxyethyl methacrylate) polyHEMA hydrogel associated to polypropylene mesh reduces visceral adhesion formation in rats, although it may be associated to greater inflammatory reaction.


OBJETIVO: Verificar se compósito poli 2-hidroxietil dimetacrilato (PoliHEMA) / tela de polipropileno implantado na parede abdominal de ratas seria adequado para prevenção de aderências peritoneais e avaliar a resposta tecidual desencadeada por este biomaterial. MÉTODOS: Foram implantadas telas de polipropileno - Grupo PP (n=20) e telas de polipropileno revestidas por uma camada de poli 2 (hidroxietil dimetacrilato)-PolyHEMA - Grupo PH (n=20) na parede abdominal de ratas da linhagem Wistar. Dez animais de cada grupo foram submetidos à eutanásia aos 15 e 30 dias de pós-operatório. RESULTADOS: Os animais do grupo PP apresentaram aderências viscerais na superfície da tela, o que não foi observado nos do grupo PH. Observou-se no exame histopatológico resposta tipo corpo estranho nos dois grupos sendo que no grupo PH houve maior intensidade de resposta inflamatória nos dois momentos. CONCLUSÃO: O hidrogel de poliHEMA quando associado à tela de polipropileno reduz a formação de aderências viscerais em ratos, embora possa estar associado à reação inflamatória mais intensa.


Assuntos
Animais , Feminino , Ratos , Parede Abdominal/cirurgia , Implantes Experimentais , Doenças Peritoneais/prevenção & controle , Peritônio/efeitos dos fármacos , Polipropilenos/efeitos adversos , Telas Cirúrgicas/efeitos adversos , Parede Abdominal/patologia , Materiais Biocompatíveis , Reação a Corpo Estranho/etiologia , Reação a Corpo Estranho/patologia , Inflamação/patologia , Doenças Peritoneais/etiologia , Peritônio/patologia , Poli-Hidroxietil Metacrilato/efeitos adversos , Ratos Wistar , Técnicas de Sutura , Aderências Teciduais/patologia , Aderências Teciduais/prevenção & controle
2.
Acta cir. bras ; 25(4): 342-346, July-Aug. 2010. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-553241

RESUMO

PURPOSE: To evaluate whether the lining facing the visceral side of polypropylene mesh made with 2-hydroxyethyl methacrylate (p(HEMA)) hydrogel could avoid peritoneal adhesion in female dogs. METHODS: Eight animals (group PP) had a polypropylene mesh implanted to correct a defect in the rectal abdominal muscle, whereas in the other group (group PH) the polypropylene mesh was coated with p(HEMA) composite on the surface facing the peritoneal area. RESULTS: Adhesions were observed on the mesh in 62.5 percent of the PP group. In the PH group adhesions were present only on the suture lines. CONCLUSION: p(HEMA) hydrogel was well tolerated and effective in avoiding visceral and omental adhesions on the surface of the polypropylene mesh.


OBJETIVO: Avaliar se o revestimento da face visceral de uma tela de polipropileno com 2-hidroxietil dimetacrilato (p(HEMA)) poderia evitar aderências peritoniais em cadelas. MÉTODOS: Em oito animais (Grupo PP) foram implantadas telas de polipropileno para correção de um defeito do músculo reto abdominal, enquanto em outro grupo (Grupo PH) fez-se a implantação de uma tela de polipropileno cuja face peritonial foi revestida por 2-hidroxietil dimetacrilato (p(HEMA)). RESULTADOS: Foram observados 62,5 por cento de aderências peritoniais sobre a tela nos animais do Grupo PP, enquanto que no Grupo PH estas não ocorreram, exceto sobre a linha se sutura. CONCLUSÃO: O hidrogel de p(HEMA) foi bem tolerado pelos animais e mostrou-se efetivo na prevenção das aderências viscerais e omentais sobre a tela de polipropileno.


Assuntos
Animais , Cães , Feminino , Músculos Abdominais/cirurgia , Materiais Biocompatíveis/uso terapêutico , Hidrogéis/uso terapêutico , Doenças Peritoneais/prevenção & controle , Complicações Pós-Operatórias/prevenção & controle , Telas Cirúrgicas , Resinas Compostas/química , Implantes Experimentais , Teste de Materiais , Aderências Teciduais/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA