Acta cir. bras ; 36(8): e360803, 2021. tab, graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1339010

RESUMO

ABSTRACT Purpose: To compare the blood flow in the internal thoracic artery when dissected endoscopically in a conventional manner, in addition to develop a reliable experimental training model for the surgical team. Methods: Paired experimental study. Ten pigs were operated and had both internal thoracic arteries dissected, the right with a conventional technique and the left by video endoscopy. The main outcomes to be studied were flow, length, and time of dissection of each vessel. Results: Blood flow measurements were performed with mean heart rate of 100 ± 16 bpm and mean arterial pressure of 89.7 ± 13 mm Hg. The mean blood flow of endoscopic dissection of the internal thoracic artery was 170.2 ± 66.3 mL/min and by direct view was 180.8 ± 70.5 (p = 0.26). Thus, there was no statistically significant difference between the flows, showing no inferiority between the methods. Conclusions: The minimally invasive dissection of the internal thoracic artery was shown to be not inferior to the dissection by open technique in relation to the blood flow in the present experimental model. In addition, the model that we replicated was shown to be adequate for the development of the learning curve and improvement of the endoscopic abilities.


Assuntos
Animais , Artéria Torácica Interna/cirurgia , Suínos , Dissecação , Endoscopia , Hemodinâmica