Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Cardiovascular Ultrasound ; : 247-250, 2016.
Artigo em Inglês | WPRIM | ID: wpr-201295

RESUMO

Unicuspid aortic valve (UAV) is an extremely rare form of congenital aortic valvular abnormality. Although UAV shows similar clinical characteristics to bicuspid aortic valve, the clinical symptoms develop at earlier age and progress at a faster pace in UAV. In this report, we are presenting a 42-year-old male with severe aortic stenosis associated with unicommissural UAV. The patients underwent a successful Bentall operation.


Assuntos
Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Aneurisma Aórtico , Estenose da Valva Aórtica , Valva Aórtica , Dente Pré-Molar
2.
Korean Circulation Journal ; : 466-475, 2001.
Artigo em Coreano | WPRIM | ID: wpr-156316

RESUMO

BACKGROUND: Rotational atherectomy has been shown to be safe and efficient for the treatment of ISR, but the recurrence rate is still high. Intracoronary-irradiation after rotational atherectomy may be a reasonable approach to prevent recurrent ISR. SUBJECTS & METHODS: Fifty consecutive patients with diffuse ISR (length > 10 mm) in native coronary arteries underwent rotational atherectomy and adjunctive balloon angioplasty followed by beta irradiation using a 188Re-MAG3-filled balloon catheter. The radiation dose was 15 Gy at 1.0 mm deep into vessel wall. RESULTS: Mean length of the lesion and irradiated segment was 25.6 +/- 12.7 mm and 37.6 +/- 11.2 mm, respectively. The radiation was delivered successfully to all patients, with a mean irradiation time of 201.8 61.7 seconds. No adverse event including myocardial infarction, death, or stent thrombosis occurred during the follow-up period (mean 10.3 +/- 3.7 months) and non-target vessel revascularization was needed in one patient. Six-month binary angiographic restenosis rate was 10.4 % and loss index was 0.17 +/- 0.31. CONCLUSIONS: beta irradiation using 188Re-MAG3-filled balloon following rotational atherectomy is safe and feasible for patients with diffuse ISR, and it may improve the clinical and angiographic outcomes. Further prospective randomized trials are warranted to evaluate the synergistic effect of debulking and irradiation in patients with diffuse ISR.


Assuntos
Humanos , Angioplastia com Balão , Aterectomia Coronária , Catéteres , Vasos Coronários , Seguimentos , Infarto do Miocárdio , Recidiva , Stents , Trombose
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA