Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Artigo em Português | LILACS | ID: lil-758432

RESUMO

O presente trabalho teve por objetivo validar métodos por espectrofotometria UV-Vis e por CLAE para a análise quantitativa de um derivado do tiofeno, o 2-[(3,4-dicloro-benzilideno)-amino]-5,6-diidro-4H-ciclopen-ta[b]tiofeno-3-carbonitrila (5CN05) e aplicá-los no doseamento da molécula contida em microemulsões, Os métodos propostos foram validados conforme a Resolução 899/2003 da Agência Nacional de Vigilância Sanitária (ANVISA), O comprimento de onda de máxima absorção do fármaco 5CN05 foi detectado em λ max= 387nm, O método espectrofotométrico validado mostrou-se seletivo, apresentando linearidade na faixa de 3 a 16 µg.mL-1, coeficiente de correlação (r) igual a 0,9998 e limites de detecção e quantificação de 0,12 µg.mL-1 e 0,41 µg.mL-1, respectivamente, Para o método CLAE, observou-se linearidade na faixa de 0,1 a 3,0 µg.mL-1, r = 0,99915, limites de detecção e quantificação de 0,07 µg.mL-1 e 0,10 µg.mL-1 respectivamente, Para ambos os métodos, os parâmetros precisão, exatidão e robustez mostraram-se adequados para o uso pretendido, As metodologias propostas podem ser seguramente aplicadas para quantificação do 5CN05 em produtos farmacêuticos como microemulsões...


This study aims to validate methods of Uv-Vis) and HPLC for quantitative determination of a thiophene derivative, 2 - [(3,4-dichloro -benzylidene)-amino] -5,6-dihydro-4H-cyclopentyl-ta [b] thiophene-3- carbonitrile referred in this study as 5CN05, and apply them to quantify the 5CN05 in microemulsions. The proposed methods were validated according to the Resolution RE 899/2003 of the National Health Surveillance Agency (ANVISA). The 5CN05 was detected by UV-Vis at λ max= 387nm. The validated UVVis UVVis method proved to be selective, showing linearity in the range of 3-16 µg.mL-1, correlation coefficient (r) of 0.9998 and limits of detection and quantification of 0.12 µg.mL-1 and 0.41 µg.mL-1 respectively. For the CLAE method the linearity was observed in the range 0.1 to 3.0 µg.mL-1, r = 0.99915, limits of detection and quantification of 0.07 µg.mL-1 and 0.10 µg.mL-1 respectively. For both UV-Vis and CLAE methods, the precision parameters, accuracy and robustness were adequate for the intended use. The proposed methodologies can be safely applied to quantify the 5CN05 in pharmaceutical microemulsions products...


Assuntos
Humanos , Antifúngicos , Preparações Farmacêuticas , Tiofenos/análise , Espectrofotometria/métodos
2.
RBCF, Rev. bras. ciênc. farm. (Impr.) ; 43(2): 231-238, abr.-jun. 2007. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-460183

RESUMO

The development and validation of a simple and accurate method based on HPLC with ultraviolet detection for the quantification of norfloxacin (NFX) in human plasma and its application to a bioequivalence study between two norfloxacin formulations is described. NFX and the internal standard (cyprofloxacin) were extracted from plasma using liquid-liquid extraction. Chromatographic separation of norfloxacin, cyprofloxacin and plasma interferents was achieved with a C-18 column and a mobile phase consisting of 20 mM sodium hydrogen phosphate buffer pH 3.0 and acetonitrile (88:12, v/v) and quantitation was done at 280 nm. The method was linear from 25 to 3000 ng mL-1 (r² > 0.997578), and norfloxacin and cyprofloxacin had an average recovery from plasma of 93.9 percent and 91.2 percent respectively. The RSD of inter-day quality control samples at the lower limit of quantification was less than 15 percent. After a single oral dose (400 mg) of norfloxacin administered to healthy human volunteers using a randomized 2x2 crossover design, pharmacokinetic parameters (AUC0-t, AUC0-00, Cmax, t1/2) were derived from the plasma concentration curves for both formulations. Pharmacokinetic analysis of the data showed that the two formulations were bioequivalent, while no adverse reactions to the drug were observed.


O desenvolvimento e validação de um método simples e preciso por CLAE-UV para quantificação de norfloxacino (NFX) em plasma humano e a sua aplicação a um estudo de bioequivalência entre duas formulações são descritos. NFX e o padrão interno (ciprofloxacino, PI) foram extraídos do plasma através de extração líquido-líquido. A separação cromatográfica do NFX, do PI e dos interferentes do plasma foi realizada com uma coluna C-18 e fase móvel composta de tampão fosfato de sódio 20 mM pH 3,0 e acetonitrila (88/12, v/v) e quantificado em 280 nm. A resposta do detector aos analitos mostrou-se linear entre 25 a 3000 ng mL-1 (r² > 0,997578) e a recuperação média de NFX e PI foi de 93,9 por cento e 91,2 por cento respectivamente. O desvio padrão relativo de amostras analisadas ao nível do limite inferior de quantificação foi menor que 15 por cento. Foi administrada uma dose de NFX (400 mg) por via oral a voluntários humanos em um estudo aberto, aleatório e cruzado 2x2 entre duas formulações. Os parâmetros farmacocinéticos (AUC0-t, AUC0-00, Cmáx, T1/2) foram observados a partir da curva de concentração versus tempo. A análise farmacocinética mostrou que as duas formulações são bioequivalentes entre si. Nenhum efeito adverso foi observado.


Assuntos
Norfloxacino/farmacocinética , Plasma/metabolismo , Cromatografia Líquida/métodos , Equivalência Terapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA