RESUMO
The GORE EXCLUDER Conformable abdominal aortic aneurysm (AAA) Endoprosthesis (CEXC), is currently the newest stent-graft system for treating patients with AAA. CEXC is approved for patients with proximal aortic neck angles ≤90° with a ≥15 mm aortic neck length or proximal aortic neck angles ≤60° with ≥10 mm aortic neck length. The present study describes a clinical series of 5 males with AAA, one of whom had a ruptured infrarenal AAA and a 90° proximal aortic neck angle. All patients were treated with 100% technical success using the CEXC device. Dosimetric data were recorded regarding the total kerma-area product and total fluoroscopy time. During the 30-day follow-up, no device migration or failure was detected, whereas type Ib and II endoleaks were observed in two patients. The type Ib endoleak required re-intervention with limb extension placement, and the type II endoleak was treated with lumbar artery embolization. This clinical series showed that CEXC has no technical defects or AAA-related mortality. We also reviewed the current knowledge on CEXC’s clinical outcomes, showing promising technical and clinical results in some studies, even outside the instructions for use. CEXC expands the vascular surgeons’ armamentarium against hostile neck anatomy, as it is the only repositionable endovascular aneurysm repair device available. Multicenter, long-term outcome studies should confirm the promising preliminary results of our case series and the literature review.
RESUMO
The ALTO abdominal stent graft system (Endologix Inc., Irvine, CA, USA) is a latest-generation polymer-based device used to treat patients with abdominal aortic aneurysms. The present study describes the first case series of patients with abdominal aortic aneurysms, including two patients with juxtarenal aneurysms, treated using the ALTO stent graft system. Six males were treated using the ALTO device at a single public center. All procedures were uneventful, and the dosimetric results recorded in terms of kerma-area product and fluoroscopy time were similar to those reported in previous studies. At the 1-month follow-up, computed tomography angiography showed no evidence of endoleak, device migration, thrombosis, or structural graft failure. This clinical series demonstrates that the use of the ALTO stent graft system is associated with promising patient outcomes. Lifelong postoperative imaging surveillance may highlight possible late failures and suggest potential graft improvements.
RESUMO
We report a case of successful open repair of a 7.5-cm juxtarenal abdominal aortic aneurysm (AAA) in the presence of a left-sided inferior vena cava (LS-IVC) crossing the aorta at the level of the renal arteries in a 72-year-old man. The orifice of the right renal artery was slightly caudal to that of the left renal artery and concomitant occlusive diseases of both iliac arteries were present. Based on the imaging and intraoperative findings, repair of the juxtarenal AAA was performed with mobilization of the LS-IVC, which was encircled twice with soft silicone rubber vessel loops on both sides of operating field and the blood content of the LS-IVC was temporarily evacuated. This procedure allowed proximal control with inter-renal clamping of the aorta and placement of an aortobifemoral polytetrafluoroethylene graft.
RESUMO
The optimal management of patients with asymptomatic carotid stenosis (ACS) is the subject of extensive debate. According to the 2017 European Society for Vascular Surgery guidelines, carotid endarterectomy should (Class IIa; Level of Evidence: B) or carotid artery stenting may be considered (Class IIb; Level of Evidence: B) in the presence of one or more clinical/imaging characteristics that may be associated with an increased risk of late ipsilateral stroke (e.g., silent embolic infarcts on brain computed tomography/magnetic resonance imaging, progression in the severity of ACS, a history of contralateral transient ischemic attack/stroke, microemboli detection on transcranial Doppler, etc.), provided documented perioperative stroke/death rates are 5 years. Besides these clinical/imaging characteristics, there are additional individual, ethnic/racial or social factors that should probably be evaluated in the decision process regarding the optimal management of these patients, such as individual patient needs/patient choice, patient compliance with best medical treatment, patient sex, culture, race/ethnicity, age and comorbidities, as well as improvements in imaging/operative techniques/outcomes. The present multispecialty position paper will present the rationale why the management of patients with ACS may need to be individualized.
RESUMO
We report a case of successful open repair of a 7.5-cm juxtarenal abdominal aortic aneurysm (AAA) in the presence of a left-sided inferior vena cava (LS-IVC) crossing the aorta at the level of the renal arteries in a 72-year-old man. The orifice of the right renal artery was slightly caudal to that of the left renal artery and concomitant occlusive diseases of both iliac arteries were present. Based on the imaging and intraoperative findings, repair of the juxtarenal AAA was performed with mobilization of the LS-IVC, which was encircled twice with soft silicone rubber vessel loops on both sides of operating field and the blood content of the LS-IVC was temporarily evacuated. This procedure allowed proximal control with inter-renal clamping of the aorta and placement of an aortobifemoral polytetrafluoroethylene graft.
RESUMO
The optimal management of patients with asymptomatic carotid stenosis (ACS) is the subject of extensive debate. According to the 2017 European Society for Vascular Surgery guidelines, carotid endarterectomy should (Class IIa; Level of Evidence: B) or carotid artery stenting may be considered (Class IIb; Level of Evidence: B) in the presence of one or more clinical/imaging characteristics that may be associated with an increased risk of late ipsilateral stroke (e.g., silent embolic infarcts on brain computed tomography/magnetic resonance imaging, progression in the severity of ACS, a history of contralateral transient ischemic attack/stroke, microemboli detection on transcranial Doppler, etc.), provided documented perioperative stroke/death rates are 5 years. Besides these clinical/imaging characteristics, there are additional individual, ethnic/racial or social factors that should probably be evaluated in the decision process regarding the optimal management of these patients, such as individual patient needs/patient choice, patient compliance with best medical treatment, patient sex, culture, race/ethnicity, age and comorbidities, as well as improvements in imaging/operative techniques/outcomes. The present multispecialty position paper will present the rationale why the management of patients with ACS may need to be individualized.
RESUMO
PURPOSE: To identify risk factors for recurrent thromboembolic events (RTEs) and define the optimum duration of treatment with tinzaparin in patients with superficial vein thrombosis (SVT) of the lower limbs. MATERIALS AND METHODS: A total of 147 consecutive patients with significant SVT were treated with subcutaneously administered tinzaparin. The composite primary endpoint of the study was RTE, deep-vein thrombosis (DVT) and/or pulmonary embolism (PE) at 120 days. Patients were stratified into group A, where patients received a variable dose of tinzaparin for up to 60 days (n=98), and a subsequent group B-ext, where patients received a standardized intermediate dose of tinzaparin (n=49) for 90 days. RESULTS: RTEs occurred in 15/147 patients (10.2%), including recurrent SVT (n=10), DVT (n=4) and fatal PE (n=1). RTEs were less frequent in group B-ext (0% vs. 15.3% for group A, P=0.004), a difference that remained significant at the one-year follow-up. Clinically extensive SVT was an independent predictor for RTEs (hazard ratio, 5.94; 95% confidence interval, 2.05–17.23; P=0.001, Cox regression). Predictors or DVT or PE in group A included clinically extensive SVT (P=0.004), absence of local pain (P=0.023) and the ultrasound findings of superficial axial vein thrombosis (any, P=0.006 or isolated, P=0.036) and multiple thrombosed superficial venous sites (P < 0.001). CONCLUSION: An extended three-month regimen of tinzaparin in patients with SVT of the lower limbs is more effective than a shorter course and may be desirable in patients with risk factors.
Assuntos
Humanos , Seguimentos , Heparina , Extremidade Inferior , Embolia Pulmonar , Recidiva , Fatores de Risco , Tromboflebite , Trombose , Ultrassonografia , Veias , Trombose VenosaRESUMO
PURPOSE: There is currently debate if brachio-basilic vein fistula (BBVF) should be performed as a one-stage or two-stage procedure. The aim of the present study was to perform a systematic review and meta-analysis on BBVF staging. MATERIALS AND METHODS: On February 25, 2016, a search for randomized-controlled trials (RCTs) on BBVF procedures was performed in MEDLINE and Scopus databases. Meta-analyses were performed with fixed-effect or random-effects models as appropriate with risk ratios (RRs). The primary efficacy and safety outcome measures were BBVF maturation and development of complications, respectively. Specific types of complications, including loss of functional secondary patency and long-term complications were all secondary outcome measures. RESULTS: We identified three RCTs reporting on 126 patients. Maturation failure of two-stage BBVFs (3/47, 6.4%) was less frequent than one-stage BBVFs (16/79, 20.3%; RR, 0.27; P=0.02). Complication rates of two-stage and one-stage BBVFs were similar (RR, 0.80; P=0.54), but on sensitivity analysis these were less likely to occur with two-stage BBVFs (37% vs. 69% for one-stage BBVFs; RR, 0.57; P=0.03). Two-stage BBVFs were less likely to lose their functional secondary patency (21.3% vs. 31.6% for one-stage BBVFs; RR, 0.61; P=0.11). This non-significant trend became significant (RR, 0.36; P=0.02) on sensitivity analysis. There was no difference in specific complication rates of the two study groups. CONCLUSION: Among candidates for BBVF fistula, there is evidence to suggest that two-stage BBVFs achieve higher maturation rates compared to one-stage BBVFs. The evidence for difference in long-term secondary patency is less robust, calling for further research.
Assuntos
Humanos , Fístula Arteriovenosa , Fístula , Razão de Chances , Avaliação de Resultados em Cuidados de Saúde , Diálise Renal , VeiasRESUMO
No abstract available.
RESUMO
A shotgun pellet is depicted in the present image in a carotid artery under the intima, which remained intact without local complications for up to six months. There is lack of data regarding the natural history of such a carotid pellet, but the experience from the myocardium is that, in the absence of infection, completely embedded missiles are usually asymptomatic, tolerated well and may be left in place.