Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Rev. Assoc. Med. Bras. (1992) ; 67(1): 29-32, Jan. 2021. graf
Artigo em Inglês | LILACS | ID: biblio-1287800

RESUMO

SUMMARY The extracorporeal membrane oxygenation (ECMO) is a procedure that has been used for a long time in reference centers worldwide. Its fundamental precept is to serve as a bridge to a definitive treatment in patients with severe, but potentially reversible, clinical conditions. Despite this, its use in cardiopulmonary arrest (ECPR) is still a matter of debate, especially when indicated in the emergency department. There is not yet a sufficient level of evidence to support its routine use. In Brasil, the procedure stopped being considered an experimental technique by the Federal Council of Medicine only in 2017. The objective of the present case is to share the pioneering spirit of a Brazilian reference center with ECPR in the emergency room and to discuss the future challenges of the ECMO technique.


Assuntos
Humanos , Masculino , Oxigenação por Membrana Extracorpórea , Reanimação Cardiopulmonar , Parada Cardíaca/terapia , Brasil , Serviço Hospitalar de Emergência , Pessoa de Meia-Idade
2.
Rev. bras. cir. cardiovasc ; 35(6): 986-989, Nov.-Dec. 2020. tab, graf
Artigo em Inglês | LILACS, SES-SP | ID: biblio-1143987

RESUMO

Abstract Since Barnard's first heterotopic heart transplant in 1974, Copeland's method has been the greatest contribution to heterotopic transplants but has the drawback of donor's right ventricular atrophy. This new method proposes a modification in the anastomosis of the superior vena cava aiming to pre-serve donor's right ventricular function by decompressing the pulmonary territory and reducing the pulmonary arterial pressure, as a biological ventricular assist device. Finally, a second intervention is proposed, where a "twist" is performed to place the donor's heart in an orthotopic position after re-moval of the native heart. A pioneering research on this method received approval from the ethics committee of the Heart Institute of São Paulo. We believe that this method has the potential to im-prove quality of life in a selected group of patients.


Assuntos
Humanos , Coração Auxiliar , Transplante de Coração , Qualidade de Vida , Veia Cava Superior , Transplante Heterotópico
3.
Rev. bras. cir. cardiovasc ; 34(5): 637-639, Sept.-Oct. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1042034

RESUMO

Abstract Quadricuspid aortic valve (QAV) is a rare cardiac malformation. Many cases are incidentally diagnosed in aortic surgeries or autopsies and it usually appears as an isolated anomaly. The most widely classification used is the one by Hurwitz and Roberts[1], which divides 7 alphabetical subtypes based on the cusps size. The aim of this report is to describe three different anatomic presentations of this rare aortic valve anomaly.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Valva Aórtica/anormalidades , Valva Aórtica/patologia , Cardiopatias Congênitas/patologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/diagnóstico por imagem
4.
Rev. méd. Minas Gerais ; 22(4)dez. 2012.
Artigo em Português | LILACS | ID: lil-698420

RESUMO

Objetivos: conhecer as indicações do uso de NOi, dose média utilizada e resposta ao tratamento em recém-nascidos internados em Unidade de Terapia Intensiva Neonatal. Métodos: foram analisados 62 prontuários e considerados dois grupos de recém-nascidos (RN) de acordo com o desfecho para sobrevida (n=39) ou óbito (n=23). Testes t-Student e binomial, p<0,05. Resultados: do total, 47 eram masculinos, 18 nasceram de parto normal e 44 de cesariana. Os RNs que sobreviveram tinham maior idade gestacional clínica e mais peso ao nascimento (p<0,05). Cardiopatia congênita, hipoplasia pulmonar, sepse e síndrome da membrana hialina (SMH) foram mais frequentes nos RNs que evoluíram para óbito, enquanto que a síndrome de aspiração de mecônio (SAM)estava mais presente nos RNs que sobreviveram (p<0,05). Não houve diferença significativa quanto a: asfixia perinatal, hérnia diafragmática, hipertensão pulmonar persistente neonatal (HPPN) e taquipneia transitória do recém-nascido (p>0,05). A dose inicial de NOi e a duração do tratamento foram maiores nos RNs que sobreviveram (p<0,05). A idade de início do tratamento, a dose máxima de NOi e o tempo de ventilação mecânica não apresentaram diferenças entre os grupos (p>0,05). O índice de oxigenação foi significativamente mais alto nos óbitos (p<0,05). Não foram observados efeitos colaterais. Conclusões: a terapia com NOi foi indicada principalmente na asfixia perinatal, SAM, SMH e sepse. As doses de NOi entre 15 e 30 ppm mostraram-se seguras e a diminuiçãodo índice de oxigenação sugere resposta positiva ao tratamento.


Objectives: To know the inhaled nitric oxide (iNO) use indications, the average used dose, and the reaction to treatment in newborns hospitalized at the Neonatal Intensive Care Unit. Methods: 62 medical records were analyzed and two newborn groups were considered according to the survival (n=39) or death (n=23) outcome. t-Student and binomial tests, p<0.05. Results: From the total, 47 subjects were male, 18 were born from natural childbirth, and 44 from cesarean section. The newborns that survived had a higher clinical gestational age and more weight at birth (p>0.05). Congenital heart defect, pulmonary hipoplasia, sepsis, and hyaline membrane syndrome (HMS) were more frequent in newborns that evolved to death, while the meconium aspiration syndrome (MAS) was more present in the ones that survived (p<0.05). There was no significant difference concerning: perinatal asphyxia, diaphragmatichernia, neonatal persistent pulmonary hypertension (NPPH), and newborn transient taquipneia (p>0.05). The iNO initial dose and treatment time were superior in newborns that survived (p<0.05). Age in the beginning of the treatment, maximum doses of iNO, and time of mechanical ventilation did not present significant differences between the groups (p>0.05).The oxygenation index was significantly higher in the deceased ones (p<0.05). No adverse effects were seen. Conclusions: Therapy with iNO was mainly indicated for perinatal asphyxia, MAS, HMS, and sepsis. iNO doses between 15 and 30 ppm proved to be safe, and the decrease of the oxygenation index suggests a positive reaction to the treatment.


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Síndrome da Persistência do Padrão de Circulação Fetal/tratamento farmacológico , Óxido Nítrico/uso terapêutico , Asfixia Neonatal/prevenção & controle
5.
Hig. aliment ; 23(168/169): 156-160, jan.-fev. 2009. ilus, tab
Artigo em Português | LILACS | ID: lil-549332

RESUMO

A excelência do leite materno como fonte de alimentação exclusiva para lactentes até os seis meses de idade não constitui motivo de dúvida, uma vez que esse alimento possui uma composição química que corresponde perfeitamente às necessidades fisiológicas do metabolismo normal do bebê. Porém, existem vários fatores que impedem o processo natural de amamentação, surgindo assim a necessidade de centros de armazenamento e distribuição de leite humano, os Bancos de leite Humano. Sabendo-se que o leite humano é um alimento extremamente nutritivo, passível de contaminação, e tendo em vista os receptores de tal alimento, um rígido controle de qualidade torna-se necessário. Assim, técnicas adequadas e sensíveis de controle de qualidade são importantes. Os objetivos do estudo foram testar a eficácia do Teste da Fosfatase Alcalina, utilizado rotineiramente em leite de vaca, em leite humano e avaliar o padrão microbiológico dos leites pasteurizados...


Assuntos
Humanos , Lactente , Fosfatase Alcalina , Microbiologia de Alimentos , Bancos de Leite Humano , Leite Humano
6.
Rev. bras. cir. cardiovasc ; 23(1): 132-134, jan.-mar. 2008. ilus
Artigo em Inglês, Português | LILACS | ID: lil-489716

RESUMO

Relatamos o caso de uma paciente de 46 anos, cor branca, hipertensa há 20 anos, com suspeita de endocardite infecciosa. Foi realizado ecocardiograma transtorácico, o qual levou à hipótese de mixoma de átrio direito. A paciente foi submetida à cirurgia, observando-se massa tumoral de aspecto muco-gelatinoso friável. A massa foi submetida a congelação para exame anatomopatológico, com laudo sugestivo de tumor maligno mesenquimal. Foi realizado exame imunohistoquímico compatível com condrossarcoma mixóide. A paciente evoluiu com remissão espontânea do quadro após ressecção completa da neoplasia. Realizou acompanhamento ambulatorial por 14 meses, sem apresentar sinais de recidiva do tumor.


We report a case of a 46 years-old woman, Caucasian, with hypertension and a primary dianosis of infectious endocarditis. A transthoracic echocardiogram was performed suggesting right atrium myxoma. The patient was submitted to surgery, which found a tumor mass with a jelly-like exterior. The mass was sent to anatomo-pathological analysis which diagnosed a myxoid chondrosarcoma tumor. After surgical resection, the patient achieved complete recovery with no signs of recidivation after 14 months.


Assuntos
Feminino , Humanos , Pessoa de Meia-Idade , Condrossarcoma/cirurgia , Neoplasias Cardíacas/cirurgia , Mixoma/cirurgia , Condrossarcoma/patologia , Átrios do Coração , Neoplasias Cardíacas/patologia , Mixoma/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA