Chinese Journal of Radiological Medicine and Protection ; (12): 145-149, 2020.
Artigo em Chinês | WPRIM | ID: wpr-868416

RESUMO

Objective To study a method for verifying the doses to PTV and OAR as well as the 2D dose distribution arising from IMRT through using radiochromic films and TLDs.Methods Totally 7 medical electronic linear accelerators from Varian,Siemens and Elekta were selected.The polystyrene phantom provided by IAEA was conducted with CT scan.After irradiation with 6 MV X-rays,the TLDs and films were returned to the secondary standard dosimetry laboratory of China CDC for measurement and estimation.Results According to the IAEA requirements,the relative deviations between TLD-measured and TPS-planned values for PTV and OAR doses were both within ±7.0%.For PTV,the measured relative deviations for 5 accelerators were in the range of-4.0% to 3.4%,consistent with the IAEA requirements,whereas the values for the other 2 accelerators were in the range of-7.0% to 10.6%,not consistent with the requirements.For OAR,the values for 4 accelerators were in the range of-5.6% to 3.3%,consistent with the IAEA requirements,whereas the values for the other 3 accelerators were in the range of-20.8% to 11.5%,not meeting the requirements.As required by the IAEA,the 2D dose distribution 3 mm/3% pass rate should be higher than 90%.The measured values for 5 accelerators were in the range of 91.8% to 98.5%,consistent with the requirements,whereas the values measured for the other 2 were 45.0% and 77.0% respectively,not meeting the requirements.Conclusions It is feasible for using TLDs and radiochromic films to verify the doses to PTV and OAR and the 2D dose distribution in IMRT.This method should be applied to not only quality verification but also hospital internal audit to the extent possible.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 140-144, 2020.
Artigo em Chinês | WPRIM | ID: wpr-868415

RESUMO

Objective To use TLDs and radiochromic films to verify the prescribed doses to both planned target volume (PTV) and organ at risk (OAR) and the 2D dose distribution in IMRT.Methods Eight accelerators of different models were selected in Henan province.The polystyrene phantom provided by IAEA was scanned using CT scanners and then the scanned images were transmitted to treatment planning system (TPS) for prescribing respectively the doses to PTV and OAR.IMRT was performed with phantom exposed to a 6 MV X-rays.The irradiated TLDs and films were delivered for measurement and estimation at Secondary Standard Dosimetry Laboratory at National Institute for Radiological Protection,Chinese Center for Disease Control and Prevention.Results According to IAEA requirements,the relative deviations of the TLD-measured and TPS-planned values were within ±7.0% for the prescribed doses to PTV and OAR.The measured results for PTV have shown that the relative deviation of TLD-measured and TPS-planned values were within-0.3% to 6.9% for 8 accelerators,all consistent with the IAEA requirements.For OAR,the relative deviations of TLD-measured and TPS-planned were within-7.0% to 0.3% for 6 accelerators,consistent with the requirements,whereas those for other 2 accelerators were within-10.8% to-8.4%,not up to the requirements.IAEA required that,for 2D dose distribution,the pass rate of 3 mm/3% be ≥ 90%.The measured values for 7 accelerators were from 90.2% to 99.9%,consistent with the requirements,whereas that for another one was 70.0%,not meeting the requirement.Conclusions The method to verify,using radiochromic film and TLD,the prescribed doses to PTV and OAR and the pass rate of 2D dose distribution is simple and reliable.It is an important step to implement quality control for IMRT and can provide effective support for medical or third-party service institution to verify clinically prescribed dose.

3.
Chinese Journal of Radiological Medicine and Protection ; (12): 134-139, 2020.
Artigo em Chinês | WPRIM | ID: wpr-868414

RESUMO

Objective To study a method to measure the doses to planned target volume (PTV) and organ at risk (OAR) and 2D dose distribution in IMRT by using TLD and radiochromic film for a verification purpose.Methods Totally 7 different types of medical linear accelerators were selected from seven hospitals in Hubei province.A polystyrene phantom provided by IAEA was CT scanned and then the scanned images were returned to the Treatment Planning System (TPS) for determining the prescribed doses to PTS and OAR and the corresponding MU.After the phantom was irradiated with 6 MV X-ray,the TLDs and films were transmitted to the secondary standard dosimetry laboratory of China CDC for measurement and estimation.Results The IAEA required the relative deviations between TLD-measured and TPS-planned doses to OAR and PTV be within ±7.0%.For PTV,the measured-to-planned deviation values for 7 accelerator were within-5.4% to 6.5%,all consistent with the IAEA requirements.For OAR,the values for 5 accelerators were within-2.2% to 6.7%,not consistent the requirements,whereas the values for the other 2 were-8.6% and 8.2% respectively,beyond the required values.The IAEA required that the 2D dose distribution 3 mm/3% pass rate be higher than 90%.The measured values for 7 accelerators were in the range of 90.3%-98.9%,all consistent with the requirements.Conclusions It is feasible scientifically and easy to operate in practice for using TLD and film to carry out dose verification in IMRT.It would be advisable to apply this method to quality verification in IMRT in medical institutions to the extent possible.

4.
Chinese Journal of Radiological Medicine and Protection ; (12): 129-133, 2020.
Artigo em Chinês | WPRIM | ID: wpr-868413

RESUMO

Objective To validate the method for measuring the TPV and OAR doses and 2D dose distribution in IMRT through using TLD and radiochromic film.Methods Eight medical linear accelerators (Valian,Elekta,Siemens) were selected.The polystyrene phantom provided by IAEA was CT scanned and the image obtained was transferred to TPS for formulation of treatment plan,prescription of PTV and OAR doses and calculation of corresponding monitoring unit (MU),IMRT was performed on the phantom using 6 MV X-ray.Irradiated TLDs and films were measured and evaluated at the Secondary Standard Dosimetry Laboratory at the Radiation Safety Institute of Chinese Center for Disease Control and Prevention.Results According to IAEA requirement,the relative deviations between TLD-measured and TPS-planned doses were within ±7.0% for the prescribed PTV and OAR doses.As measured result,the PTV values for 8 accelerators were in the range of 0.6% to 5.9%,consistent with the IAEA requirements,whereas the OAT values for 8 accelerators were within-0.6% to 7.0%,consistent the requirements.As IAEA required,the 2D dose distribution passing rate of 3 mm/3% should be higher than 90%.The filmmeasured and TPS-planned values for 8 accelerators were within 90.2% to 100.0%,consistent with the requirements.Conclusions TLD and radiochromic film are feasible in validating the PTV and OAR doses and the 2D dose distribution pass rate in IMRT.This method can be widely used in quality audit and internal verification in IMRT in medical institutiions on a large scale.

5.
Chinese Journal of Radiological Medicine and Protection ; (12): 122-128, 2020.
Artigo em Chinês | WPRIM | ID: wpr-868412

RESUMO

Objective To develop the methodology for using TLD and radiochromic film to measure the planned target volume (PTV) and organ at risk (OAR) doses and 2D dose distribution in IMRT,in order to provide technical guidance on the dose quality audit in IMRT at home.Methods China has participated in the research project launched by the international multi-radiotherapy centre (IMRC).IMRT polystyrene phantom provided by IAEA was scanned by CT scanner and then the scanned images were transmitted to TPS to outline prescribed dose to PTV and to OAR.The former was limited to 400 cGy while the latter limited to 200 cGy.IMRT was implemented with the phantom irradiated using 6 MV X-ray.The irradiated TLDs and films were sent to IAEA dosimerty laboratory for measurement and calculation.Jiangsu,Sichuan,Hubei and Henan provinces were selected to engage with this study for their variety of accelerators and highly skilled physicists.The procedures used were the same as in the IMRC and the irradiated TLDs and films were required to send to external audit group for measurement and calculation.Results According to IAEA requirement,the relative deviations of the TLD-measured and TPS planned doses are within ±7.0% for PTV and OAR.The China's research results at the IMRC have shown that the relative deviation of TLD-measured and TPS-planned values for the upper and lower PTV were-0.2% and 0.8%,respectively,consistent with the IAEA requirement,and the values for upper and lower OAR were -0.6% and-1.0%,respectively,consistent with the requirement.As the results have shown in four provinces,the relative deviations of the TLD-measured and TPS-planned were within 0 to 10.6% for upper and lower PTV and-0.6% to 20.9% for upper and lower OAR.According to IAEA requirement,the passing rate should be greater than 90% for 3 mm /3% for 2D dose distribution.China's result at the IMRC is 100%,being excellent.The four provinces' results have shown that 2D dose distribution pass rate of 3 mm/3% was in the range of 45.0%-100.0%.Conclusions The uses of TLD in quality audit for PTV and OAR doses and the radiochromic film in 2D dose distribution pass rate in IMRT are characterized by scientific feasibility,strong operability,easy-to-mail and data realibility.They are can be applied to quality assurance and audit in medical institutions in the country to on a large scale.

6.
Chinese Journal of Radiological Medicine and Protection ; (12): 145-149, 2020.
Artigo em Chinês | WPRIM | ID: wpr-799421

RESUMO

Objective@#To study a method for verifying the doses to PTV and OAR as well as the 2D dose distribution arising from IMRT through using radiochromic films and TLDs.@*Methods@#Totally 7 medical electronic linear accelerators from Varian, Siemens and Elekta were selected. The polystyrene phantom provided by IAEA was conducted with CT scan. After irradiation with 6 MV X-rays, the TLDs and films were returned to the secondary standard dosimetry laboratory of China CDC for measurement and estimation.@*Results@#According to the IAEA requirements, the relative deviations between TLD-measured and TPS-planned values for PTV and OAR doses were both within ±7.0%. For PTV, the measured relative deviations for 5 accelerators were in the range of -4.0% to 3.4%, consistent with the IAEA requirements, whereas the values for the other 2 accelerators were in the range of -7.0% to 10.6%, not consistent with the requirements. For OAR, the values for 4 accelerators were in the range of -5.6% to 3.3%, consistent with the IAEA requirements, whereas the values for the other 3 accelerators were in the range of -20.8% to 11.5%, not meeting the requirements. As required by the IAEA, the 2D dose distribution 3 mm/3% pass rate should be higher than 90%. The measured values for 5 accelerators were in the range of 91.8% to 98.5%, consistent with the requirements, whereas the values measured for the other 2 were 45.0% and 77.0% respectively, not meeting the requirements.@*Conclusions@#It is feasible for using TLDs and radiochromic films to verify the doses to PTV and OAR and the 2D dose distribution in IMRT. This method should be applied to not only quality verification but also hospital internal audit to the extent possible.

7.
Chinese Journal of Radiological Medicine and Protection ; (12): 140-144, 2020.
Artigo em Chinês | WPRIM | ID: wpr-799420

RESUMO

Objective@#To use TLDs and radiochromic films to verify the prescribed doses to both planned target volume (PTV) and organ at risk (OAR) and the 2D dose distribution in IMRT.@*Methods@#Eight accelerators of different models were selected in Henan province. The polystyrene phantom provided by IAEA was scanned using CT scanners and then the scanned images were transmitted to treatment planning system (TPS) for prescribing respectively the doses to PTV and OAR. IMRT was performed with phantom exposed to a 6 MV X-rays. The irradiated TLDs and films were delivered for measurement and estimation at Secondary Standard Dosimetry Laboratory at National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention.@*Results@#According to IAEA requirements, the relative deviations of the TLD-measured and TPS-planned values were within ±7.0% for the prescribed doses to PTV and OAR. The measured results for PTV have shown that the relative deviation of TLD-measured and TPS-planned values were within -0.3% to 6.9% for 8 accelerators, all consistent with the IAEA requirements. For OAR, the relative deviations of TLD-measured and TPS-planned were within -7.0% to 0.3% for 6 accelerators, consistent with the requirements, whereas those for other 2 accelerators were within -10.8% to -8.4%, not up to the requirements. IAEA required that, for 2D dose distribution, the pass rate of 3 mm/3% be ≥90%. The measured values for 7 accelerators were from 90.2% to 99.9%, consistent with the requirements, whereas that for another one was 70.0%, not meeting the requirement.@*Conclusions@#The method to verify, using radiochromic film and TLD, the prescribed doses to PTV and OAR and the pass rate of 2D dose distribution is simple and reliable. It is an important step to implement quality control for IMRT and can provide effective support for medical or third-party service institution to verify clinically prescribed dose.

8.
Chinese Journal of Radiological Medicine and Protection ; (12): 134-139, 2020.
Artigo em Chinês | WPRIM | ID: wpr-799419

RESUMO

Objective@#To study a method to measure the doses to planned target volume (PTV) and organ at risk (OAR) and 2D dose distribution in IMRT by using TLD and radiochromic film for a verification purpose.@*Methods@#Totally 7 different types of medical linear accelerators were selected from seven hospitals in Hubei province. A polystyrene phantom provided by IAEA was CT scanned and then the scanned images were returned to the Treatment Planning System (TPS) for determining the prescribed doses to PTS and OAR and the corresponding MU. After the phantom was irradiated with 6 MV X-ray, the TLDs and films were transmitted to the secondary standard dosimetry laboratory of China CDC for measurement and estimation.@*Results@#The IAEA required the relative deviations between TLD-measured and TPS-planned doses to OAR and PTV be within ±7.0%. For PTV, the measured-to-planned deviation values for 7 accelerator were within -5.4% to 6.5%, all consistent with the IAEA requirements. For OAR, the values for 5 accelerators were within -2.2% to 6.7%, not consistent the requirements, whereas the values for the other 2 were -8.6% and 8.2% respectively, beyond the required values. The IAEA required that the 2D dose distribution 3 mm/3% pass rate be higher than 90%. The measured values for 7 accelerators were in the range of 90.3%-98.9%, all consistent with the requirements.@*Conclusions@#It is feasible scientifically and easy to operate in practice for using TLD and film to carry out dose verification in IMRT. It would be advisable to apply this method to quality verification in IMRT in medical institutions to the extent possible.

9.
Chinese Journal of Radiological Medicine and Protection ; (12): 129-133, 2020.
Artigo em Chinês | WPRIM | ID: wpr-799418

RESUMO

Objective@#To validate the method for measuring the TPV and OAR doses and 2D dose distribution in IMRT through using TLD and radiochromic film.@*Methods@#Eight medical linear accelerators (Valian, Elekta, Siemens) were selected. The polystyrene phantom provided by IAEA was CT scanned and the image obtained was transferred to TPS for formulation of treatment plan, prescription of PTV and OAR doses and calculation of corresponding monitoring unit (MU), IMRT was performed on the phantom using 6 MV X-ray. Irradiated TLDs and films were measured and evaluated at the Secondary Standard Dosimetry Laboratory at the Radiation Safety Institute of Chinese Center for Disease Control and Prevention.@*Results@#According to IAEA requirement, the relative deviations between TLD-measured and TPS-planned doses were within ±7.0% for the prescribed PTV and OAR doses. As measured result, the PTV values for 8 accelerators were in the range of 0.6% to 5.9%, consistent with the IAEA requirements, whereas the OAT values for 8 accelerators were within -0.6% to 7.0%, consistent the requirements. As IAEA required, the 2D dose distribution passing rate of 3 mm/3% should be higher than 90%. The film-measured and TPS-planned values for 8 accelerators were within 90.2% to 100.0%, consistent with the requirements.@*Conclusions@#TLD and radiochromic film are feasible in validating the PTV and OAR doses and the 2D dose distribution pass rate in IMRT. This method can be widely used in quality audit and internal verification in IMRT in medical institutiions on a large scale.

10.
Chinese Journal of Radiological Medicine and Protection ; (12): 122-128, 2020.
Artigo em Chinês | WPRIM | ID: wpr-799417

RESUMO

Objective@#To develop the methodology for using TLD and radiochromic film to measure the planned target volume (PTV) and organ at risk (OAR) doses and 2D dose distribution in IMRT, in order to provide technical guidance on the dose quality audit in IMRT at home.@*Methods@#China has participated in the research project launched by the international multi-radiotherapy centre (IMRC). IMRT polystyrene phantom provided by IAEA was scanned by CT scanner and then the scanned images were transmitted to TPS to outline prescribed dose to PTV and to OAR. The former was limited to 400 cGy while the latter limited to 200 cGy. IMRT was implemented with the phantom irradiated using 6 MV X-ray. The irradiated TLDs and films were sent to IAEA dosimerty laboratory for measurement and calculation. Jiangsu, Sichuan, Hubei and Henan provinces were selected to engage with this study for their variety of accelerators and highly skilled physicists. The procedures used were the same as in the IMRC and the irradiated TLDs and films were required to send to external audit group for measurement and calculation.@*Results@#According to IAEA requirement, the relative deviations of the TLD-measured and TPS planned doses are within ±7.0% for PTV and OAR. The China′s research results at the IMRC have shown that the relative deviation of TLD-measured and TPS-planned values for the upper and lower PTV were -0.2% and 0.8%, respectively, consistent with the IAEA requirement, and the values for upper and lower OAR were -0.6% and -1.0%, respectively, consistent with the requirement. As the results have shown in four provinces, the relative deviations of the TLD-measured and TPS-planned were within 0 to 10.6% for upper and lower PTV and -0.6% to 20.9% for upper and lower OAR. According to IAEA requirement, the passing rate should be greater than 90% for 3 mm /3% for 2D dose distribution. China′s result at the IMRC is 100%, being excellent. The four provinces′ results have shown that 2D dose distribution pass rate of 3 mm/3% was in the range of 45.0%-100.0%.@*Conclusions@#The uses of TLD in quality audit for PTV and OAR doses and the radiochromic film in 2D dose distribution pass rate in IMRT are characterized by scientific feasibility, strong operability, easy-to-mail and data realibility. They are can be applied to quality assurance and audit in medical institutions in the country to on a large scale.

11.
Chinese Journal of Gastrointestinal Surgery ; (12): 1041-1050, 2019.
Artigo em Chinês | WPRIM | ID: wpr-801343

RESUMO

Objective@#To investigate the diagnosis and treatment for enterocutaneous fistula (ECF) in China, and to explore the prognostic factors of ECF.@*Methods@#A multi-center cross-sectional study was conducted based on the Registration System of Chinese Gastrointestinal Fistula and Intra-Abdominal Infections to collect the clinical data of ECF patients from 54 medical centers in 22 provinces/municipalities from January 1, 2018 to December 31, 2018. The clinical data included patient gender, age, length of hospital stay, intensive care unit (ICU) admission, underlying diseases, primary diseases, direct causes of ECF, location and type of ECF, complications, treatment and outcomes. All medical records were carefully filled in by the attending physicians, and then re-examined by more than two specialists. The diagnosis of ECF was based on the clinical manifestations, laboratory/imaging findings and intraoperative exploration.@*Results@#A total of 1521 patients with ECF were enrolled, including 1099 males and 422 females, with a median age of 55 years. The top three primary diseases of ECF were malignant tumors in 626 cases (41.2%, including 540 gastrointestinal tumors, accounting for 86.3% of malignant tumors), gastrointestinal ulcers and perforations in 202 cases (13.3%), and trauma in 157 cases (10.3%). The direct causes of ECF were mainly surgical operation in 1194 cases (78.5%), followed by trauma in 156 (10.3%), spontaneous fistula due to Crohn′s disease in 92 (6.0%), radiation intestinal injury in 41 (2.7%), severe pancreatitis in 20 (1.3%), endoscopic treatment in 13 (0.9%) and 5 cases (0.3%) of unknown reasons. All the patients were divided into three groups: 1350 cases (88.7%) with simple ECF, 150 (9.9%) with multiple ECF, and 21 (1.4%) with combined internal fistula. Among the patients with simple ECF, 438 cases (28.8%) were jejuno-ileal fistula, 313 (20.6%) colon fistula, 170 (11.2%) rectal fistula, 111 (7.3%) duodenal fistula, 76 (5.0%) ileocecal fistula, 65 (4.3%) ileocolic anastomotic fistula, 55 (3.6%) duodenal stump fistula, 36 (2.4%) gastrointestinal anastomotic fistula, 36 (2.4%) esophagogastric/esophagojejunal anastomotic fistula, 29 (1.9%) gastric fistula and 21 (1.4%) cholangiopancreatiointestinal. Among all the simple ECF patients, 991 were tubular fistula and 359 were labial fistula. A total of 1146 patients finished the treatment, of whom 1061 (92.6%) were healed (586 by surgery and 475 self-healing) and 85 (7.4%) died. A total of 1043 patients (91.0%) received nutritional support therapy, and 77 (6.7%) received fistuloclysis. Infectious source control procedures were applied to 1042 patients, including 711 (62.0%) with active lavage and drainage and 331 (28.9%) with passive drainage. Among them, 841 patients (73.4%) underwent minimally invasive procedures of infectious source control (replacement of drainage tube through sinus tract, puncture drainage, etc.), 201 (17.5%) underwent laparotomy drainage, while 104 (9.1%) did not undergo any drainage measures. A total of 610 patients (53.2%) received definitive operation, 24 patients died within postoperative 30-day with mortality of 3.9% (24/610), 69 (11.3%) developed surgical site infection (SSI), and 24 (3.9%) had a relapse of fistula. The highest cure rate was achieved in ileocecal fistula (100%), followed by rectal fistula (96.2%, 128/133) and duodenal stump fistula (95.7%,44/46). The highest mortality was found in combined internal fistula (3/12) and no death in ileocecal fistula. Univariate prognostic analysis showed that primary diseases as Crohn′s disease (χ2=6.570, P=0.010) and appendicitis/appendiceal abscess (P=0.012), intestinal fistula combining with internal fistula (χ2=5.460, P=0.019), multiple ECF (χ2=7.135, P=0.008), esophagogastric / esophagojejunal anastomotic fistula (χ2=9.501, P=0.002), ECF at ileocecal junction (P=0.012), non-drainage/passive drainage before the diagnosis of intestinal fistula (χ2=9.688, P=0.008), non-drainage/passive drainage after the diagnosis of intestinal fistula (χ2=9.711, P=0.008), complicating with multiple organ dysfunction syndrome (MODS) (χ2=179.699, P<0.001), sepsis (χ2=211.851, P<0.001), hemorrhage (χ2=85.300, P<0.001), pulmonary infection (χ2=60.096, P<0.001), catheter-associated infection (χ2=10.617, P=0.001) and malnutrition (χ2=21.199, P<0.001) were associated with mortality. Multivariate prognostic analysis cofirmed that sepsis (OR=7.103, 95%CI:3.694-13.657, P<0.001), complicating with MODS (OR=5.018, 95%CI:2.170-11.604, P<0.001), and hemorrhage (OR=4.703, 95%CI: 2.300-9.618, P<0.001) were independent risk factors of the death for ECF patients. Meanwhile, active lavage and drainage after the definite ECF diagnosis was the protective factor (OR=0.223, 95%CI: 0.067-0.745, P=0.015).@*Conclusions@#The overall mortality of ECF is still high. Surgical operation is the most common cause of ECF. Complications e.g. sepsis, MODS, hemorrhage, and catheter-associated infection, are the main causes of death. Active lavage and drainage is important to improve the prognosis of ECF.

12.
Chinese Journal of Gastrointestinal Surgery ; (12): 1027-1033, 2019.
Artigo em Chinês | WPRIM | ID: wpr-801341

RESUMO

Objective@#To understand the prevalence, diagnosis and treatment of chronic critical illness (CCI) in China.@*Methods@#The clinical data of 472 adult patients admitted to ICU in 53 hospitals, including basic information, disease-related data, nutrition program, etc., were collected on May 10, 2019, by means of multi-center cross-sectional study. If surgical intervention was needed or the occurrence of the disease was directly related to the surgery, ICU patients were regarded as surgical ICU cases (n=211). In this study, the diagnostic criteria for CCI were: (1) admission to ICU >14 days;(2) combined with persistent organ dysfunction. The prevalence,distribution and treatment of CCI and surgery-related CCI were recorded and analyzed. The Mann-Whitney U test, chi-square test or Fisher exact test were used for comparative analysis.@*Results@#Among the 472 ICU patients from 53 hospitals, 326 were male (69.1%) and 146 were female (30.9%). The prevalence of CCI was 30.7% (145/472). Among 211 surgery-related ICU patients, 57 developed CCI with a prevalence of 27.0%. As compared to non-CCI patients, higher APACHE II score [median (IQR) 13.5 (10.0, 18.3) vs. 11.0 (7.0, 16.0), U=2970.000, P=0.007], higher Charlson comorbidity index [median (IQR) 4.0 (2.0, 7.0) vs. 3.0 (1.0, 5.0), U= 3570.000, P=0.036] and higher ratio of breath dysfunction [68.4% (39/57) vs. 48.1% (74/154), χ2=6.939, P=0.008] and renal dysfunction [42.1% (24/57) vs. 18.2% (28/154), χ2=12.821, P<0.001] were found in surgery-related CCI patients. While SOFA score, Glasgow coma score and other visceral function were not significantly different between surgery-related CCI and non-CCI patients (all P>0.05). NUTRIC score showed that surgery-related CCI patients had higher nutritional risk [43.9% (25/57) vs. 26.6%(41/154), U=5.750, P=0.016] and higher ratio of mechanical ventilation [66.7% (38/57) vs. 52.3% (79/154), χ2=3.977, P=0.046] than non-CCI patients. On the survey day, the daily caloric requirements of 50.2% (106/211) of surgery-related ICU patients were calculated according to the standard adult caloric intake index (104.6 to 125.5 kJ·kg-1·d-1, 1 kJ=0.239 kcal), and the daily caloric requirements of 46.4% (98/211) of patients were calculated by physicians according to the severity of the patient′s condition. 60.2% (127/211) of nutritional support therapy was enteral nutrition (including a combination of enteral and parenteral nutrition), while the remaining patients received parenteral nutrition (24.6%, 52/211), simple glucose infusion (9.0%, 19/211), or oral diet (6.2%, 13/211). The target calorie of CCI group was 104.6 (87.9, 125.5) kJ·kg-1·d-1, and the actual calorie intake accounted for 0.98 (0.80, 1.00) of the target calory. In the non-CCI group, the target calorie was 104.6 (87.9, 125.5) kJ·kg-1·d-1, and the actual calorie consumed accounted for 0.91 (0.66, 1.00) of the target calorie. There was no statistically significant difference between two groups (P=0.248, P=0.150).@*Conclusion@#The prevalence of CCI and surgery-related CCI in ICU is high, along with severe complications, respiratory and renal dysfunction and mechanical ventilation. Surgical patients admitted to ICU are at high nutritional risk, and active and correct nutritional support is essential for such patients.

13.
Chinese Journal of Radiological Medicine and Protection ; (12): 121-127, 2019.
Artigo em Chinês | WPRIM | ID: wpr-734326

RESUMO

Objective To develop measurement methodology using film for the positioning accuracy of MLC leaves in IMRT.Methods The solid water phantom of 30 cm x 30 cm was scanned and the scanned images were transferred to TPS for treatment plan formulation.The five MLC strip picket fence pattern was formed by MLC leaves,each 3.0 cm long × 6.0 mm wide.The separation between strip and strip is 3.0 cm.SAD is 100 cm at dmax for 6 MV X-ray,with 250 MU per MLC strip.EBT2 radiochomic film was put on the phantom for delivery of IMRT,for each MLC strip.The present study focused on 30 accelerators of Varian,Elekta and Siemens designs at 27 hospitals with highly skilled physicists all over Jiangsu,Sichuan,Hubei and Henan provinces.The study was conducted in the same way as used in international multi-radiotherapy center (IMRC).The irradiated films were sent respectively to IAEA dosimetry laboratory and external audit group (EGA) of China for measurement,analysis and calculation.Results According to IAEA requirements,the differenc of film-measured and TPS-planned of MLC leaf position for each strip should be within ±0.5 mm.China had participated in the research of IMRC,with the result of 0.3,0.2,0.0,-0.1,and-0.2 mm,respectively.For 30 accelerators in four provinces involved in the study,the IAEA's verification results of MLC leaf position were within 0.6-1.0 mm for 5 accelerators and within ± 0.5 mm for other 25 ones.Whereas the verification results of EAG were within 0.6-1.0 mm for 6 accelerators and within ±0.5 mm for other 24 ones.According to IAEA requirements,the film-measured MLC leaf position deviation for each pair of leaves and average all pairs of leaves should be within ±0.5 mm.China had participated in IMRC's research,with the measured result being 0.04 mm.The verification result of EGA for 30 accelerators showed the measured MLC leaf position deviations were all <0.3 mm per strip,consistent with IAEA requirements.The IAEA's result showed the measured deviations of MLC leaf position for 29 accelerators were within ±0.5 mm,with only other one being-0.7 mm not consistent with the IAEA requirements.As required by IAEA,the difference of film-measured difference of MLC opening width should be within ±0.75 mm between each pair and average all pairs of leaves.China's result in research of IMRC showed the difference of minimum width to mean width was-0.2 mm whereas the difference of maximum width to mean width was 0.4 mm.For 30 accelerators involved in IAEA'verification study,the measured result shown that the difference between maximum and average of filmmeasured of MLC leaf width,and between minmum and average,were within ± 0.75 mm for 24 accelerators,in line with the IAEA requirements.For other 6 ones,the values were beyond ±0.75 mm,not in line with the IAEA requirements.For the verification result of EAG,the difference between maximum and average widths and between minmum and average widths for 25 accelerators were within ±0.75 mm as required by IAEA,whereas for other 5 ones the value were beyond ±0.75 mm,not consistent with IAEA requirements.The standard deviation of film-measured MLC opening width between each pair and average all pairs should be within 0.3 mm as required by IAEA.China's IMRC result was 0.12 mm.The verification result of IAEA shown the standard deviation of MLC opening position were <0.3 mm for 26 accelerators and > 0.3 mm for other 4 accelerators.EAG verification result were the same as IAEA result.Conclusions The method using radiochromic film for measuring accuracy of MLC leaf position is convenient and practicable as a quality audit.It is suitable for quality verification in medical institutions owing to easy to post and repeated measurements.

14.
Chinese Journal of Gastrointestinal Surgery ; (12): 1366-1373, 2018.
Artigo em Chinês | WPRIM | ID: wpr-774447

RESUMO

OBJECTIVE@#To determine the incidence of surgical site infection (SSI) after abdominal surgery and to further evaluate the related risk factors of SSI in China.@*METHODS@#The multicenter cross-sectional study collected clinical data of all adult patients who underwent abdominal surgery from May 1, 2018 to May 31, 2018 in 30 domestic hospitals, including basic information, perioperative parameters, and incisional microbial culture results. The primary outcome was the incidence of SSI within postoperative 30 days. SSI was classified into superficial incision infection, deep incision infection, and organ/gap infection according to the US Centers for Disease Control and Prevention (CDC) criteria. The secondary outcome variables were ICU stay, postoperative hospital stay, total hospital stay, 30-day mortality and treatment costs. Multivariate logistic regression was used to analyze the risk factors of SSI.@*RESULTS@#A total of 1666 patients were enrolled in the study, including 263 cases of East War Zone Hospital of PLA, 140 cases of Affiliated Hospital of Qingdao University, 108 cases of The First Affiliated Hospital of Nanchang University, 87 cases of Central War Zone Hospital of PLA, 77 cases of West China Hospital, 74 cases of Guangdong General Hospital, 71 cases of Chenzhou First People's Hospital, 71 cases of Zigong First People's Hospital, 64 cases of Zhangjiagang First People's Hospital, 56 cases of Nanyang City Central Hospital, 56 cases of Lanzhou General Hospital of Lanzhou Military Command, 56 cases of Shandong Provincial Hospital, 52 cases of Shangqiu First People's Hospital, 52 cases of People's Hospital of Xinjiang Uygur Autonomous Region, 48 cases of The Second Xiangya Hospital of Central South University, 48 cases of Chinese PLA General Hospital, 44 cases of Affiliated Hospital of Xuzhou Medical University, 38 cases of Hunan Province People's Hospital, 36 cases of Dongguan Kanghua Hospital, 30 cases of Shaoxing Central Hospital, 30 cases of Northern Jiangsu People's Hospital, 29 vases of The First Affiliated Hospital of Zhengzhou University, 27 cases of General Hospital of Tianjin Medical University, 22 cases of Zigong Fourth People's Hospital, 21 cases of The Second Hospital of University of South China, 18 cases of Tongji Hospital, 15 cases of Nanchong Central Hospital, 12 cases of The 901th Hospital of PLA, 11 cases of Hunan Cancer Hospital, 10 cases of Lanzhou University Second Hospital. There were 1019 males and 647 females with mean age of (56.5±15.3) years old. SSI occurred in 80 patients (4.8%) after operation, including 39 cases of superficial incision infection, 16 cases of deep incision infection, and 25 cases of organ/interstitial infection. Escherichia coli was the main pathogen of SSI, and the positive rate was 32.5% (26/80). Compared with patients without SSI, those with SSI had significantly higher ICU occupancy rate [38.8%(31/80) vs. 13.9%(220/1586), P<0.001], postoperative hospital stay (median 17 days vs. 7 days, P<0.001) and total hospital stay (median 22 days vs. 13 days, P<0.001), and significantly higher cost of treatment (median 75 000 yuan vs. 44 000 yuan, P<0.001). Multivariate analysis showed that male rise(OR=2.110, 95%CI:1.175-3.791, P=0.012), preoperative blood glucose level rise(OR=1.100, 95%CI: 1.012-1.197, P=0.026), operative time (OR=1.006, 95%CI:1.003-1.009, P<0.001) and surgical incision grade (clean-contaminated incision:OR=10.207, 95%CI:1.369-76.120, P=0.023; contaminated incision: OR=10.617, 95%CI:1.298-86.865, P=0.028; infection incision: OR=20.173, 95%CI:1.768-230.121, P=0.016) were risk factors for SSI; and laparoscopic surgery (OR=0.348, 95%CI:0.192-0.631, P=0.001) and mechanical bowel preparation(OR=0.441,95%CI:0.221-0.879, P=0.020) were protective factors for SSI.@*CONCLUSIONS@#The incidence of postoperative SSI in patients with abdominal surgery in China is 4.8%. SSI can significantly increase the medical burden of patients. Preoperative control of blood glucose and mechanical bowel preparation are important measures to prevent SSI.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Abdome , Cirurgia Geral , China , Estudos Transversais , Cirurgia Geral , Duração da Cirurgia , Complicações Pós-Operatórias , Período Pré-Operatório , Estudos Retrospectivos , Fatores de Risco , Infecção da Ferida Cirúrgica
15.
Chinese Journal of Radiological Medicine and Protection ; (12): 368-373, 2018.
Artigo em Chinês | WPRIM | ID: wpr-708071

RESUMO

Objective To measure the doses to eye lens and hands of workers,using thermo luminescent dosimeter (TLD) and optically stimulated luminescence dosimeter (OSLD).Methods TLDs in the same batch were annealed,packed and stuck to the flat abdomen of Alderson-Phantom at a distance of about 15 cm from 125I seed source,while irradiated at different doses:1.0,1.5,3.0,5.0,10.0,12.0,20.0,25.0,30.0,50.0 and 60.0 μ Gy.And then TLDs were measured by dosimeters to establish a dose calibration curve.By implanting seed source into the selected lung for 14 cases,belly for 10 cases,pelvic for 5 case and neck for 6 cases while placing calibrated TLDs on the left,middle and right above eyes,left and right hands of the workers to obtain the location-specific kerma values.Finally,the conversion factors Hp (3) and Hp (0.07) were used to calculate the values of dose equivalent to eye lens and hands.Additionally,OSLDs were used to measure the doses to workers in the same way.Results The TLD-measured eye lens dses to the operator and his assistant were 0.8 and 1.6 mSv in lungs,1.3 and 1.2 mSv in bellies,0.9 and 0.6 mSv in pelves,0.3 mSv in necks,respectively.Meanwhile,hand doses to the operator and his assistant were 1.4 and 2.1 mSv in lungs,1.2 and 1.0 mSv in bellies,0.5 and 0.9 mSv in pelves,0.1 mSv in necks,respectively.The maximum doses to eye lens and hands were 1.2 and 1.0 mSv,respectively in a single treatment.OSLD-measured dose equivalents from lung therapy were 0.2 and 0.1 mSv for eye lens of the operator and his assistant and 0.4 and 0.6 mSv for hands.For belly therapy,the accumulated dose equivalent to hands of the operator was 0.1 mSv while those for other types of therapy were 0 mSv.Conclusions TLDs have the capability to measure not only accumulated dose but also dose equivalent from a single therapy According to ICRP 118 publication and as estimated in the present study,the number of therapy should be not more than 17 every year.OSLDs only give the accumulated dose,the accuracy of which needs to be studied in low-dose measurement.

16.
Chinese Journal of Radiological Medicine and Protection ; (12): 134-137, 2018.
Artigo em Chinês | WPRIM | ID: wpr-708029

RESUMO

Objective To measure absorbed dose and verify two-dimensional dose distribution from IMRT MLC using thermoluminescence dosimeters (TLDs) and films.Methods The teflon phantom was scanned by CT and its images were transmitted to TPS for planning.The 6 Gy-corresponding MUs were calculated at 90 cm SSD and 10 cm depth and on 5 cm × 5 cm radiation field.All the plans were implemented at 7 medical linear accelerators,which were produced by Varian,Elekta and Siemens and selected from 7 third-grade first-class hospitals according to the technical conditions of various regions in Sichuan province.The homogeneous solid phantoms used in hospitals were covered by 30 cm × 30 cm and 25 cm × 25 cm films.Then,the films were covered by thicker-than-20 cm phantoms.Finally,the plans were implemented by aligning the center of beams to the films center.Results The relative deviations of the measured absorbed dose to TPS-planned dose were 1.4%,3.7%,-2.5%,-0.3%,4.9%,4.9%,5.0% for TLDs and 4.7%,4.3%,1.5%,3.9%,-1.6%,3.3%,-1.3% for films,respectively,all consistent with the limit of less than 5%.The passing rates of 2D dose distribution (3 mm/3%) were 99.9%,98.5%,98.5%,97.9% and 70.0% for 5 accelerators,with only one not consistent with the requirements.Conclusions It is convenient to measure the absorbed dose to photon beam field and verify two-dimensional dose distribution using TLDs and films,which can provide quality assurance for radiation treatment plans.

17.
Chinese Journal of Radiological Medicine and Protection ; (12): 129-133, 2018.
Artigo em Chinês | WPRIM | ID: wpr-708028

RESUMO

Objective To verify the absorbed dose and two-dimensional dosimetry delivered by MLC-shaped IMRT photon beams using thermoluminescent dosimeters (TLDs) and radiochromic films.Methods Different types of medical linear accelerators at 7 third-grade first-class hospitals in Hubei were selected for this audit study.Besides TLDs and films,a small polystyrene phantom measuring 15 cm × 15 cm × 15 cm,supplied by the International Atomic Energy Agency (IAEA),was also used.The TPS dose calculation were performed with 6 MV X-ray beam and by delivering 6 Gy dose to the TLDs or films at 10 cm depth for 5 cm × 5 cm field size at 90 cm SSD.After irradiation,comparations were conducted of dose derivations between TPS-calculated values and TLD-or film-measured values.The two-dimensional dosimetry audit was carried out by using 30 cm × 30 cm homogeneous solid phantoms in which a 25 cm × 25 cm film was located at 5 cm depth.A single-filed profile generated by TPS was delivered to the film,and the film was measured.And then,two-dimensional dose distribution was analyzed using the film analysis system.Results The results suggested that the relative deviations of TLD and film to TPS dose was-8.5% and-1.9% for accelerator 1,5.4% and 0.5% for accelerator 7,respectively,whereas those for other accelerators were within ± 5%.The passing rates for two-dimensional dose distribution at all accelerators were all higher than 90%.Conclusions TLD and film quality audit for IMRT can be applied for a wide range of application in view of its simplicity,reliability and postal convenience.

18.
Chinese Journal of Radiological Medicine and Protection ; (12): 115-120, 2018.
Artigo em Chinês | WPRIM | ID: wpr-708025

RESUMO

Objective To develop the methodology for using TLDs and films to measure absorbed dose and 2D dose distribution produced by the multi-leaf collimator (MLC) in intensity modulated radiotherapy (IMRT),in order to provide the guidance on dose quality audit in IMRT.Methods A total of 30 different-typed accelerators were selected from 27 hospitals in Jiangsu,Sichuan,Hubei and Henan provinces,including 17 Varian accelerators,10 Elektas and 3 Simens.The same batch of films and TLDs were put in a 2 cm-thick solid plate for fixation and then loaded in a 15 cm × 15 cm × 15 cm polysyrene solid phantom supplied by International Atomic Energy Agency(IAEA) in terms of 90 cm SSD,19 cm depth,10 cm × 10 cm field at different doses.The standard dose curves wcrc established for film and TLD,respectively.The irradiated film was measured and then sent to the External Audit Group (EAG) in China.The TLD-and film-absorbed doses were compared with TPS-calculated doses.The 2D dose distribution on the IRMT MLC field was measured using films.The homogeneous phanton of 30 cn × 30 cm was scanned by CT and the image was transferred to the TPS.The IMRT was implemented with 6 Gy fractionated irradiation by placing a 25 cm × 25 cm film on the phantom surface at 95 cm SSD and at 5 cm depth.The irradiated film was sent to the IAEA dosimetry laboratory for measurement and calculation.2D dose distribution verification was conducted in thc same way consistent with the procedure of international multi-radiotherapy center.The 3 mm/3% passing rate was calculated for 2D dose distribution and compared with the film-measured and TPS calculated result.Results IAEA requires the relative deviation of TLD and film measured absorbed dose are with in ± 5%.The relative deviation of TLD-and filmmeasured to TPS-calculated absorbed dose was within the range of ±0.7%-± 8.5% and within ±0.3% ±7.8% in Jiangsu,Sichuan,Hubei and Henan provinces,respectively.IAEA requires the 3 mm/3% passing rate of film-measured 2D distribution to be 90%.The result of the present study were up to 94.0%.The verification result of 2D dose distribution were within 70.0%-99.9% in Sichuan,Jiangsu,Hubei and Henan provinces.Conclusions The adsorbed dose and 2D distribution can be audited using TLDs and films for MLC in IRMT.The method is scientific and applicable,economical and convenient for development of dose quality audit for a wide range of IRMT.

19.
International Journal of Surgery ; (12): 324-327, 2017.
Artigo em Chinês | WPRIM | ID: wpr-620941

RESUMO

Objective To review the causes of 21 cases of exteric fistula after surgery,treatment and prognosis,and to explore the clinical treatment of exteric fistula after surgery.Methods To collection the Xinjiang Uygur Autonomous Region People's Hospital of Gastrointestinal Surgery from Aug 2013 to Aug.2016 admitted during the period of parenteral fistula patients after abdominal surgery,21 patients with intestinal fistula outside,12 cases were male,9 were female cases.According to the case records of descriptive statistics,the treatment methods was summarized and analyzed retrospectively.Results Au patients with intestinal fistula outside,12 cases were male,female 9 cases.Conservative treatment of 11 cases,healing in 2 cases,5 cases,4 cases died and the sigmoid colon perforation repair 1 case,postoperative ileus postoperative renal function failure in 1 case,gastric cancer by intraperitoneal hemorrhage after early postoperative restrictive ploration in 2 cases;Early surgical treatment of 10 cases,of which the deterministic operation in 1 case,late deterministic surgery in 9,were cured.Conclusions The early diagnosis of parenteral fistula and rapid processing,taken on the basis of the condition of the patients with timely complete drainage,infection control,reasonable nutrition support and correct homeostasis imbalance as the main content of a comprehensive individualized treatment,most patients can improve the self-healing,cannot heal patients to choose the appropriate surgical timing and proper operation method,can improve the cure rate and reduce the case fatality rate.

20.
Chinese Journal of Radiological Medicine and Protection ; (12): 780-783, 2015.
Artigo em Chinês | WPRIM | ID: wpr-480997

RESUMO

Objective To investigate muli-leaf collimator (MLC)-defined small field output factors calculated by the treatment planning system (TPS), and to study the measuring method of small field output factors verified by 0.015 cc PinPoint ionization chamber.Methods Eight medical accelerators for intensity-modulated radiation therapy (IMRT) were investigated in Henan province, and TPS-calculated output factors for various small fields (6 cm ×6 cm,4 cm ×4 cm,3 cm ×3 cm and 2 cm ×2 cm) were compared with published values recommended by IAEA.If the relative deviation was more than ± 3% for the 2 cm ×2 cm field size and ±2% for the fields of 6 cm ×6 cm, 4 cm ×4 cm and 3 cm ×3 cm, which was beyond the scope of IAEA allowed, the output factors will be measured and verified using 0.015 cc PinPoint ionization chamber and Unidos electrometer.Results TPS-calculated small field output factors for eight medical accelerators were compared with published values.The relative deviation of small field output factors for five pieces of equipment, which accounted for 62.5% of the total, met the IAEA's requirement, while the other three, which accounted for 37.5% of the total, did not.After measuring with PinPoint ionization chamber, the results from only three pieces of equipment met minimum IAEA's requirement.Conclusions MLC-defined small field output factors calculated by TPS for some medical accelerators in Henan need to be measured and corrected using micro-ionization chamber, and the measured values could be taken as the basis of radiation treatment planning.