Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
Yonsei Medical Journal ; : 618-624, 2023.
Artigo em Inglês | WPRIM | ID: wpr-1003240

RESUMO

Purpose@#Tinnitus is one of the most common health conditions worldwide. Although various methods of treatment have been used, the condition is still difficult to manage or cure. This study aimed to evaluate the therapeutic effects of transcutaneous trigeminal electrical stimulation (TTES) combined with notched sound therapy (NST) on patients with tinnitus. @*Materials and Methods@#A clinical trial was conducted prospectively from September 2020 to September 2021 at a single center in South Korea. In total, 14 patients took part in this trial. Periodic visits and tele-monitoring were used to assess treatment compliance and collect data, including electroencephalography (EEG), photoplethysmography (PPG), tinnitus handicap inventory (THI), tinnitus magnitude index, Beck Depression Inventory (BDI), Pittsburgh Sleep Quality Index (PSQI), and 36-item short-form survey (SF-36) results. @*Results@#Changes after intervention were analyzed with paired t-test. This study showed that alpha waves in the left hemisphere measured by EEG (p=0.024), autonomic nervous system balance (p=0.007), and stress level (p=0.022) measured by PPG significantly changed after intervention. Also, THI scores especially emotional symptoms (p=0.029) and catastrophic symptoms (p=0.043) decreased after treatment. The SF-36 score, both mental component summary and physical component summary score (each p<0.001), increased significantly, whereas the PSQI score (p<0.001) and BDI score (p<0.001) decreased after TTES and NST. @*Conclusion@#Based on the results of our study, we could confirm that TTES combined with NST can significantly improve tinnitus, catastrophic symptoms, and the overall quality of life of patients.

2.
Clinical and Experimental Otorhinolaryngology ; : 69-76, 2022.
Artigo em Inglês | WPRIM | ID: wpr-925717

RESUMO

Objectives@#. This study was conducted to evaluate the user satisfaction, efficacy, and safety of round window (RW) vibroplasty using the Vibrant Soundbridge (VSB) in patients with persistent mixed hearing loss after mastoidectomy. @*Methods@#. The study included 27 patients (mean age, 58.7 years; age range, 28–76 years; 11 men and 16 women) with mixed hearing loss after mastoidectomy from 15 tertiary referral centers in Korea. The VSB was implanted at the RW. The Korean translation of the Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire and the Korean version of the International Outcome Inventory for Hearing Aids (K-IOI-HA) questionnaire were used to evaluate user satisfaction as the primary outcome. The secondary outcome measures were audiological test results and complication rates. @*Results@#. The mean scores for ease of communication (61.3% to 29.7% to 30.2%), reverberation (62.1% to 43.1% to 37.4%), and background noise (63.3% to 37.7% to 34.3%) subscales of the APHAB questionnaire significantly decreased after VSB surgery. The mean K-IOI-HA scores at 3 and 6 months after surgery were significantly higher than the mean preoperative score (18.6 to 27.2 to 28.1). The postoperative VSB-aided thresholds were significantly lower than the preoperative unaided and hearing aid (HA)-aided thresholds. There was no significant difference between preoperative unaided, preoperative HA-aided, and postoperative VSB-aided maximum phonetically balanced word-recognition scores. None of the 27 patients experienced a change in postoperative bone conduction pure tone average. One patient developed temporary facial palsy and two developed surgical wound infections. @*Conclusion@#. RW vibroplasty resulted in improved satisfaction and audiological test results in patients with mixed hearing loss after mastoidectomy, and the complication rate was tolerable.

3.
Journal of Audiology & Otology ; : 80-88, 2021.
Artigo em Inglês | WPRIM | ID: wpr-914770

RESUMO

Background and Objectives@#Non-linear frequency compression (NLFC) technology compresses and shifts higher frequencies into a lower frequency area that has better residual hearing. Because consonants are uttered in the high-frequency area, NLFC could provide better speech understanding. The aim of this study was to investigate the clinical effectiveness of NLFC technology on the perception of speech and music in patients with high-frequency hearing loss. @*Subjects and Methods@#Twelve participants with high-frequency hearing loss were tested in a counter-balanced order, and had two weeks of daily experience with NLFC set on/off prior to testing. Performance was repeatedly evaluated with consonant tests in quiet and noise environments, speech perception in noise, music perception and acceptableness of sound quality rating tasks. Additionally, two questionnaires (the Abbreviated Profile of Hearing Aid Benefit and the Korean version of the International Outcome Inventory-Hearing Aids) were administered. @*Results@#Consonant and speech perception improved with hearing aids (NLFC on/off conditions), but there was no significant difference between NLFC on and off states. Music perception performances revealed no notable difference among unaided and NLFC on and off states. The benefits and satisfaction ratings between NLFC on and off conditions were also not significantly different, based on questionnaires, however great individual variability preferences were noted. @*Conclusions@#Speech perception as well as music perception both in quiet and noise environments was similar between NLFC on and off states, indicating that real world benefits from NLFC technology may be limited in Korean adult hearing aid users.

4.
Korean Journal of Otolaryngology - Head and Neck Surgery ; : 540-547, 2021.
Artigo em Coreano | WPRIM | ID: wpr-920158

RESUMO

Background and Objectives@#Several drugs which can improve blood flow have been used as treatment options for sudden sensorineural hearing loss (SSNHL) based on the theory that improvement of perfusion into the inner ear will help restore hearing. Lipo-prostaglandin E1 (lipo-PGE1) is a well-known vasodilator that increases peripheral blood flow. The purpose of this study was to investigate the effect of lipo-PGE1 on the recovery of the SSNHL patients with hypertension or diabetes.Subjects and Method We retrospectively analyzed 801 patients who were diagnosed with SSNHL from January 2007 to December 2018. All patients were treated with 48 mg of methylprednisolone for 5 days; some patients received lipo-PGE1, depending on the attending physician. They were divided into four groups according to the presence or absence of hypertension and diabetes. Hearing test was performed again one month after treatment and compared with the test results at the time of diagnosis. @*Results@#As a result of comparing the hearing thresholds before and after the treatment in each group, there was a significant improvement in hearing thresholds in all groups (p<0.001). However, when comparing the effect of lipo-PGE1 for hearing change, there was a significant difference only in the group without any underlying diseases (p=0.016). @*Conclusion@#In this study, we show that lipo-PGE1 was helpful in hearing recovery when used in patients without underlying diseases rather than patients with hypertension or diabetes. Further studies will be needed to determine the therapeutic effects of lipo-PGE1 as an adjuvant treatment in SSNHL patients.

5.
Korean Journal of Otolaryngology - Head and Neck Surgery ; : 101-107, 2020.
Artigo em Coreano | WPRIM | ID: wpr-920101

RESUMO

Background and Objectives@#The purpose of this study was to figure out the clinical effectiveness of the bluetooth wireless streaming when used with a hearing aid during cell phone conversation for hearing-impaired listeners.Subjects and Method Twenty-four adults with hearing loss participated (mild: 3, moderate: 13, moderately severe: 8) in the study. The following three objective tests and one subjective questionnaire were administered to all participants; 1) consonant and Monosyllabic test in an noisy environment, 2) speech recognition test in quiet and noisy conditions, 3) listening effort test, and 4) questionnaire about sound quality and preference. Each objective test was conducted in three different cell phone conversation environments as follows; 1) unaided condition, 2) aided condition, with the bluetooth function off, and 3) aided condition, with the bluetooth function on. @*Results@#In the aided condition with the bluetooth function off, performance on consonant and monosyllabic tests was the lowest (p<0.05). However, when the bluetooth function was turned on, the result showed statistically significant superior performance (p<0.05). For the words and sentences test in noisy conditions, using wireless streaming feature with the hearing aids were beneficial compared to not using the feature (p<0.05). However, no significant difference was found between the bluetooth off and on conditions in quiet conditions. Listening effort was significantly lower in noisy background for aided bluetooth on condition (p<0.05). There was no significant difference in sound quality according to each condition, but the preference of Bluetooth feature was overwhelmingly high. @*Conclusion@#Bluetooth wireless streaming is beneficial during phone conversation in noisy environments for users of hearing aids.

6.
Journal of Audiology & Otology ; : 61-70, 2020.
Artigo | WPRIM | ID: wpr-835550

RESUMO

To assess the academic performance, communication skills,and psychosocial development of prelingual deaf children with cochlear implants (CIs) attendingmainstream schools, and to evaluate the impact of auditory speech perception on theirclassroom performance. Subjects and Methods: As participant, 67 children with CI attendingmainstream schools were included. A survey was conducted using a structured questionnaireon academic performance in the native language, second language, mathematics, socialstudies, science, art, communication skills, self-esteem, and social relations. Additionally,auditory and speech performances on the last follow-up were reviewed retrospectively. Results:Most implanted children attending mainstream school appeared to have positive selfesteemand confidence, and had little difficulty in conversing in a quiet classroom. Also, halfof the implanted children (38/67) scored above average in general academic achievement.However, academic achievement in the second language (English), social studies, and sciencewere usually poorer than general academic achievement. Furthermore, half of the implantedchildren had difficulty in understanding the class content (30/67) or conversing withpeers in a noisy classroom (32/67). These difficulties were significantly associated with poorspeech perception. Conclusions: Improving the listening environment for implanted childrenattending mainstream schools is necessary. J Audiol Otol 2020;24(2):61-70

7.
Journal of Audiology & Otology ; : 91-98, 2020.
Artigo | WPRIM | ID: wpr-835546

RESUMO

This study aimed to compare functional hearing with the use ofa personal sound amplification product (PSAP) or a basic hearing aid (HA) among sensorineuralhearing impaired listeners. Subjects and Methods: Nineteen participants with mild-to-moderatesensorineural hearing loss (SNHL) (26-55 dB HL; pure-tone average, 0.5-4 kHz) wereprospectively included. No participants had prior experience with HAs or PSAPs. Audiograms,speech intelligibility in both quiet and noisy environments, speech quality, and preference wereassessed in three different listening conditions: unaided, with the HA, and with the PSAP. Results:The use of PSAP was associated with significant improvement in pure-tone thresholds at 1, 2,and 4 kHz compared to the unaided condition (all p<0.01). In the quiet environment, speechintelligibility was significantly improved after wearing a PSAP compared to the unaided condition(p<0.001), and this improvement was better than the result obtained with the HA. The PSAPalso demonstrated similar improvement in the most comfortable levels compared to those obtainedwith the HA (p<0.05). However, there was no significant improvement of speech intelligibilityin a noisy environment when wearing the PSAP (p=0.160). There was no significant differencein the reported speech quality produced by either device or in participant preference for thePSAP or HA. Conclusions: The current result suggests that PSAPs provide considerable benefitsto speech intelligibility in a quiet environment and can be a good alternative to compensatefor mild-to-moderate SNHL. J Audiol Otol 2020;24(2):91-98

8.
Korean Journal of Otolaryngology - Head and Neck Surgery ; : 216-220, 2019.
Artigo em Inglês | WPRIM | ID: wpr-830012

RESUMO

BACKGROUND AND OBJECTIVES@#Hearing loss is a common complication associated with Noonan syndrome (NS), and the level of hearing loss for NS patients with sensorineural loss ranged from normal to severe. Additional insights into the outcome of cochlear implantation (CI)in children with NS with or without comorbidities are needed.SUBJECTS AND METHOD: In this study, five patients with NS, four with a mutation in PTPN11 and one who tested negative in mutation screening, diagnosed with the clinical scoring systemand underwent CI at ages ranging from 16 to 50 months were retrospectively reviewed. Patientswere evaluated for auditory perception (Categories of Auditory Performance), speech production (Korean Version of the Ling's Stage), and language ability (Receptive and Expressive Vocabulary Test).@*RESULTS@#In five of the children with NS, CI was performed without any complications. Threepatients who received CI before 30 months of age showed outstanding outcomes. One patientwho received CI at 50 months showed limited benefit. One patient who was diagnosed with developmental delay and cochlear nerve hypoplasia underwent CI at 28 months with poor outcome.DISCUSSION: Our report suggests that although the benefit may be influenced by comorbidities associated with NS or delay in hearing rehabilitation, profound hearing loss in patientswith NS may be restored to normal levels in terms of auditory/speech perception and vocabulary/language development. The variable hearing outcomes also underscore the need for earlyscreening and detection of profound hearing loss, and regular follow-up for hearing evaluationin patients with NS.

9.
Journal of Korean Academy of Nursing ; : 181-190, 2019.
Artigo em Coreano | WPRIM | ID: wpr-915218

RESUMO

PURPOSE@#This study aimed to confirm the mediating effect of job involvement in the relationship between grit and turnover intention among nurses working at university hospitals.@*METHODS@#Participants included 437 nurses from university hospitals located in C city, Gyeongnam. Data were collected from January 8 to 19, 2018, using self-report questionnaires. Data were analyzed using the t-test, analysis of variance, Scheffe's test, Pearson's correlation coefficient, and multiple regression, with the SPSS/22.0 program. A mediation analysis was performed according to the Baron and Kenny, and bootstrapping methods.@*RESULTS@#There were significant relationships between grit and job involvement (r=.40, p<.001), grit and turnover intention (r=−.29, p<.001), and turnover intention and job involvement (r=−.52, p<.001). Job involvement showed partial mediating effects in the relationship between grit and turnover intention.@*CONCLUSION@#Grit increased job involvement and lowered turnover intention. Therefore, to reduce nurses' turnover intention, it is necessary to develop a program and strategies to increase their grit.

10.
Journal of Audiology & Otology ; : 145-152, 2019.
Artigo | WPRIM | ID: wpr-764218

RESUMO

BACKGROUND AND OBJECTIVES: The present study aims to investigate whether the cochlear implant electrode array design affects the electrophysiological and psychophysical measures. SUBJECTS AND METHODS: Eighty five ears were used as data in this retrospective study. They were divided into two groups by the electrode array design: lateral wall type (LW) and perimodiolar type (PM). The electrode site was divided into three regions (basal, medial, apical). The evoked compound action potential (ECAP) threshold, T level, C level, dynamic range (DR), and aided air conduction threshold were measured. RESULTS: The ECAP threshold was lower for the PM than for the LW, and decreased as the electrode site was closer to the apical region. The T level was lower for the PM than for the LW, and was lower on the apical region than on the other regions. The C level on the basal region was lower for the PM than for the LW whereas the C level was lower on the apical region than on the other regions. The DRs on the apical region was greater for the PM than for the LW whereas the DR was narrower on the apical region than on the other regions. The aided air conduction threshold was not different for the electrode design and frequency. CONCLUSIONS: The current study would support the advantages of the PM over the LW in that the PM had the lower current level and greater DR, which could result in more localized neural stimulation and reduced power consumption.


Assuntos
Potenciais de Ação , Implantes Cocleares , Orelha , Eletrodos , Estudos Retrospectivos
11.
Korean Journal of Otolaryngology - Head and Neck Surgery ; : 216-220, 2019.
Artigo em Inglês | WPRIM | ID: wpr-760117

RESUMO

BACKGROUND AND OBJECTIVES: Hearing loss is a common complication associated with Noonan syndrome (NS), and the level of hearing loss for NS patients with sensorineural loss ranged from normal to severe. Additional insights into the outcome of cochlear implantation (CI)in children with NS with or without comorbidities are needed. SUBJECTS AND METHOD: In this study, five patients with NS, four with a mutation in PTPN11 and one who tested negative in mutation screening, diagnosed with the clinical scoring systemand underwent CI at ages ranging from 16 to 50 months were retrospectively reviewed. Patientswere evaluated for auditory perception (Categories of Auditory Performance), speech production (Korean Version of the Ling's Stage), and language ability (Receptive and Expressive Vocabulary Test). RESULTS: In five of the children with NS, CI was performed without any complications. Threepatients who received CI before 30 months of age showed outstanding outcomes. One patientwho received CI at 50 months showed limited benefit. One patient who was diagnosed with developmental delay and cochlear nerve hypoplasia underwent CI at 28 months with poor outcome. DISCUSSION: Our report suggests that although the benefit may be influenced by comorbidities associated with NS or delay in hearing rehabilitation, profound hearing loss in patientswith NS may be restored to normal levels in terms of auditory/speech perception and vocabulary/language development. The variable hearing outcomes also underscore the need for earlyscreening and detection of profound hearing loss, and regular follow-up for hearing evaluationin patients with NS.


Assuntos
Criança , Humanos , Percepção Auditiva , Implante Coclear , Implantes Cocleares , Nervo Coclear , Comorbidade , Seguimentos , Audição , Perda Auditiva , Idioma , Programas de Rastreamento , Métodos , Síndrome de Noonan , Reabilitação , Estudos Retrospectivos , Vocabulário
12.
Journal of Korean Academy of Nursing ; : 181-190, 2019.
Artigo em Coreano | WPRIM | ID: wpr-739850

RESUMO

PURPOSE: This study aimed to confirm the mediating effect of job involvement in the relationship between grit and turnover intention among nurses working at university hospitals. METHODS: Participants included 437 nurses from university hospitals located in C city, Gyeongnam. Data were collected from January 8 to 19, 2018, using self-report questionnaires. Data were analyzed using the t-test, analysis of variance, Scheffe's test, Pearson's correlation coefficient, and multiple regression, with the SPSS/22.0 program. A mediation analysis was performed according to the Baron and Kenny, and bootstrapping methods. RESULTS: There were significant relationships between grit and job involvement (r=.40, p<.001), grit and turnover intention (r=−.29, p<.001), and turnover intention and job involvement (r=−.52, p<.001). Job involvement showed partial mediating effects in the relationship between grit and turnover intention. CONCLUSION: Grit increased job involvement and lowered turnover intention. Therefore, to reduce nurses' turnover intention, it is necessary to develop a program and strategies to increase their grit.


Assuntos
Hospitais Universitários , Intenção , Síndrome de Job , Negociação , Reorganização de Recursos Humanos
13.
Korean Journal of Otolaryngology - Head and Neck Surgery ; : 573-579, 2018.
Artigo em Coreano | WPRIM | ID: wpr-718231

RESUMO

BACKGROUND AND OBJECTIVES: Cochlear dead region (CDR) is a region in the cochlear where hearing loss has occurred due to damage to the inner hair cells and/or neurons. Recently, a subjective test involving a pure-tone test in the presence of threshold-equalizing noise (TEN) was introduced to identify CDR. However, for uncooperative patients, such a subjective method would be unsuitable and objective methods would be needed instead to detect CDR. The acoustic change complex (ACC) is an evoked potential elicited by changes in the ongoing sound. In this study, we developed an objective method of identifying CDR by combining ACC response with a TEN test, namely the TEN-ACC test, and investigated its feasibility in normal-hearing listeners. SUBJECTS AND METHOD: Ten normal-hearing subjects participated in this study. All subjects underwent both behavioral TEN test and electrophysiological TEN-ACC test. The stimuli for the TEN-ACC test consisted of TEN and embedded pure tones with different frequencies/signals to noise ratios (SNRs). To identify the thresholds, the range SNR of stimulation was varied from 0 to 20 dB, in stages of 4 dB. RESULTS: The ACC responses of all subjects who participated in this study were well elicited by stimuli developed for the TEN-ACC test. We confirm that the pure-tones embedded in TEN elicited the objective ACC response. CONCLUSION: The results of this study suggest that the novel TEN-ACC test can be applied to evoke ACC in normal-hearing listeners. Future research should incorporate hearing-impaired listeners to determine the feasibility of the TEN-ACC test as an objective method to identify CDR.


Assuntos
Humanos , Acústica , Potenciais Evocados , Células Ciliadas Auditivas Internas , Perda Auditiva , Métodos , Neurônios , Ruído
14.
Clinical and Experimental Otorhinolaryngology ; : 44-49, 2017.
Artigo em Inglês | WPRIM | ID: wpr-66663

RESUMO

OBJECTIVES: This study aimed to compare the outcome of endoscopic and microscopic tympanoplasty. METHODS: This was a retrospective comparative study of 73 patients (35 males and 38 females) who underwent type I tympanoplasty at Samsung Medical Center from April to December 2014. The subjects were classified into two groups; endoscopic tympanoplasty (ET, n=25), microscopic tympanoplasty (MT, n=48). Demographic data, perforation size of tympanic membrane at preoperative state, pure tone audiometric results preoperatively and 3 months postoperatively, operation time, sequential postoperative pain scale (NRS-11), and graft success rate were evaluated. RESULTS: The perforation size of the tympanic membrane in ET and MT group was 25.3%±11.7% and 20.1%±11.9%, respectively (P=0.074). Mean operation time of MT (88.9±28.5 minutes) was longer than that of the ET (68.2±22.1 minutes) with a statistical significance (P=0.002). External auditory canal (EAC) width was shorter in the ET group than in the MT group (P=0.011). However, EAC widening was not necessary in the ET group and was performed in 33.3% of patients in the MT group. Graft success rate in the ET and MT group were 100% and 95.8%, respectively; the values were not significantly different (P=0.304). Pre- and postoperative audiometric results including bone and air conduction thresholds and air-bone gap were not significantly different between the groups. In all groups, the postoperative air-bone gap was significantly improved compared to the preoperative air-bone gap. Immediate postoperative pain was similar between the groups. However, pain of 1 day after surgery was significantly less in the ET group. CONCLUSION: With endoscopic system, minimal invasive tympanoplasty can be possible with similar graft success rate and less pain.


Assuntos
Humanos , Masculino , Meato Acústico Externo , Endoscopia , Procedimentos Cirúrgicos Minimamente Invasivos , Dor Pós-Operatória , Estudos Retrospectivos , Transplantes , Membrana Timpânica , Timpanoplastia
15.
Clinical and Experimental Otorhinolaryngology ; : 56-65, 2017.
Artigo em Inglês | WPRIM | ID: wpr-66661

RESUMO

OBJECTIVES: In an effort to improve hearing aid users’ satisfaction, recent studies on trainable hearing aids have attempted to implement one or two environmental factors into training. However, it would be more beneficial to train the device based on the owner’s personal preferences in a more expanded environmental acoustic conditions. Our study aimed at developing a trainable hearing aid algorithm that can reflect the user’s individual preferences in a more extensive environmental acoustic conditions (ambient sound level, listening situation, and degree of noise suppression) and evaluated the perceptual benefit of the proposed algorithm. METHODS: Ten normal hearing subjects participated in this study. Each subjects trained the algorithm to their personal preference and the trained data was used to record test sounds in three different settings to be utilized to evaluate the perceptual benefit of the proposed algorithm by performing the Comparison Mean Opinion Score test. RESULTS: Statistical analysis revealed that of the 10 subjects, four showed significant differences in amplification constant settings between the noise-only and speech-in-noise situation (P<0.05) and one subject also showed significant difference between the speech-only and speech-in-noise situation (P<0.05). Additionally, every subject preferred different β settings for beamforming in all different input sound levels. CONCLUSION: The positive findings from this study suggested that the proposed algorithm has potential to improve hearing aid users’ personal satisfaction under various ambient situations.


Assuntos
Humanos , Acústica , Classificação , Auxiliares de Audição , Audição , Ruído , Preferência do Paciente , Satisfação Pessoal , Processamento de Sinais Assistido por Computador
16.
Korean Journal of Otolaryngology - Head and Neck Surgery ; : 96-103, 2016.
Artigo em Coreano | WPRIM | ID: wpr-652972

RESUMO

BACKGROUND AND OBJECTIVES: Consonants are uttered in the high frequency range in speech to bring out understanding of our language. As consonants convey most of the word information, listeners with high-frequency hearing loss find it hard to understand speech. Non-linear frequency compression (NLFC) technology compresses and moves higher frequencies into a lower frequency region where better residual hearing is present. The purpose of this study was to evaluate clinical effectiveness of NLFC technology in patients with high-frequency hearing loss. SUBJECTS AND METHOD: Twelve ears representing patients with sloping, high-frequency sensorineural hearing loss were involved in this study. Pure-tone audiometry and Threshold Equalizing Noise Test were conducted initially in all subjects. The subjects were tested in the counter-balanced order, and had two months of everyday experience with NLFC on/off before testing took place. A resting period intervened the two phases. Performance was repeatedly evaluated with Sound Field Audiometry, Word Recognition Score, Reception Threshold for Sentences and Korean version of International Outcome Inventory for Hearing Aids. RESULTS: Cochlear dead region was detected on 4 kHz of both ears in only one subject. Each subject showed diverse performance and satisfaction with active NLFC condition. Typically, audibility of high-frequency pure-tones improved with NLFC-on condition. However, speech perception both in quiet and noise was not much improved when compared with NLFC-off condition. CONCLUSION: The NLFC technology could improve audibility in high-frequency, but failed to demonstrate benefits regarding speech perception. Further research is needed to validate the effectiveness of the NLFC technology especially in terms of speech intelligibility.


Assuntos
Humanos , Audiometria , Audiometria de Tons Puros , Orelha , Audição , Auxiliares de Audição , Perda Auditiva de Alta Frequência , Perda Auditiva Neurossensorial , Ruído , Inteligibilidade da Fala , Percepção da Fala
17.
Clinical and Experimental Otorhinolaryngology ; : 102-110, 2015.
Artigo em Inglês | WPRIM | ID: wpr-34090

RESUMO

OBJECTIVES: The clinical effects of the simultaneous application of nonlinear frequency compression and dichotic hearing on people with hearing impairments have not been evaluated previously. In this study, the clinical effects of the simultaneous application of these two techniques on the recognition of consonant-vowel-consonant (CVC) words with fricatives were evaluated using normal-hearing subjects and a hearing loss simulator operated in the severe hearing loss setting. METHODS: A total of 21 normal-hearing volunteers whose native language was English were recruited for this study, and two different hearing loss simulators, which were configured for severe hearing loss in the high-frequency range, were utilized. The subjects heard 82 English CVC words, and the word recognition score and response time were measured. RESULTS: The experimental results demonstrated that the simultaneous application of these two techniques showed almost even performance compared to the sole application of nonlinear frequency compression in a severe hearing loss setting. CONCLUSION: Though it is generally accepted that dichotic hearing can decrease the spectral masking thresholds of an hearing-impaired person, simultaneous application of the nonlinear frequency compression and dichotic hearing techniques did not significantly improve the recognition of words with fricatives compared to the sole application of nonlinear frequency compression in a severe hearing loss setting.


Assuntos
Humanos , Testes com Listas de Dissílabos , Perda Auditiva , Audição , Máscaras , Tempo de Reação , Processamento de Sinais Assistido por Computador , Voluntários
18.
Clinical and Experimental Otorhinolaryngology ; : 329-334, 2015.
Artigo em Inglês | WPRIM | ID: wpr-91710

RESUMO

OBJECTIVES: Neuroblastoma (NBL) predominantly affects children under 5 years of age. Through multimodal therapy, including chemotherapy, radiotherapy, surgery, and peripheral blood stem cell transplantation, the survival rate in patients with NBL have improved while treatment-related complications have also increased. Treatment-related ototoxicity, mainly from cisplatin, can result in profound hearing loss requiring cochlear implantation (CI). We analyzed the effectiveness and hearing preservation of CI recipients who had treated with multimodal therapy due to NBL. METHODS: Patients who received multimodal therapy for NBL and subsequent CIs were enrolled. A detailed review of the perioperative hearing test, speech evaluation, and posttreatment complications was conducted. Speech performance was analyzed using the category of auditory performance (CAP) score and the postoperative hearing preservation of low frequencies was also compared. Patients who were candidates for electro-acoustic stimulation (EAS) used an EAS electrode for low frequency hearing preservation. RESULTS: Three patients were identified and all patients showed improvement of speech performance after CI. The average of CAP score improved from 4.3 preoperatively to 5.8 at 1 year postoperatively. Two patients who were fitted with the Flex electrode showed complete hearing preservation and the preserved hearing was maintained over 1 year. The one remaining patient was given the standard CI-512 electrode and showed partial hearing preservation. CONCLUSION: Patients with profound hearing loss resulting from NBL multimodal therapy can be good candidates for CI, especially for EAS. A soft surgical technique as well as a specifically designed electrode should be applied to this specific population during the CI operation in order to preserve residual hearing and achieve better outcomes.


Assuntos
Criança , Humanos , Cisplatino , Implante Coclear , Implantes Cocleares , Terapia Combinada , Tratamento Farmacológico , Eletrodos , Perda Auditiva , Testes Auditivos , Audição , Neuroblastoma , Transplante de Células-Tronco de Sangue Periférico , Radioterapia , Taxa de Sobrevida
19.
Clinical and Experimental Otorhinolaryngology ; : 237-242, 2015.
Artigo em Inglês | WPRIM | ID: wpr-223312

RESUMO

OBJECTIVES: The aims of this study were to find and compare the effect of directional (DIR) processing of two different hearing aids via both subjective and objective methods, to determine the association between the results of the subjective and objective evaluations, and to find out individual predictive factors influencing the DIR benefit. METHODS: Twenty-six hearing aid users fitted unilaterally with each two different experimental hearing aid performed modified Korean Hearing in Noise Test (K-HINT) in three DIR conditions; omnidirectional (OMNI) mode, OMNI plus noise reduction feature, fixed DIR mode. In order to determine benefits from DIR benefit within a hearing aid and compare performance of the DIR processing between hearing aids, a subjective questionnaire was administrated on speech quality (SQ) and discomfort in noise (DN) domain. Correlation analysis of factors influencing DIR benefit was accomplished. RESULTS: Benefits from switching OMNI mode to DIR mode within both hearing aids in K-HINT were about 2.8 (standard deviation, 3.5) and 2.1 dB SNR (signal to ratio; SD, 2.5), but significant difference in K-HINT results between OMNI and OMNI plus noise reduction algorithm was not shown. The subjective evaluation resulted in the better SQ and DN scores in DIR mode than those in OMNI mode. However, the difference of scores on both SQ and DN between the two hearing aids with DIR mode was not statistically significant. Any individual factors did not significantly affect subjective and objective DIR benefits. CONCLUSION: DIR benefit was found not only in the objective measurement performed in the laboratory but also in the subjective questionnaires, but the subjective results was failed to have significant correlation with the DIR benefit obtained in the K-HINT. Factors influencing individual variation in perceptual DIR benefit were still hard to explain.


Assuntos
Auxiliares de Audição , Perda Auditiva , Audição , Ruído , Razão Sinal-Ruído , Inteligibilidade da Fala
20.
Korean Journal of Audiology ; : 1-7, 2014.
Artigo em Inglês | WPRIM | ID: wpr-173057

RESUMO

Complex sound like speech can be characterized as the sum of number of amplitude-modulated signals representing the outputs of an array of narrow frequency bands. Temporal information at the output of each band can be separated into temporal fine structure (TFS), the rapid oscillations close to the center frequency and temporal envelope (ENV), slower amplitude modulations superimposed on the TFS. TFS information can be carried in the pattern of phase locking to the stimulus waveform, while ENV by the changes in firing rate over time. The relative importance of temporal ENV and TFS information in understanding speech has been studied using various sound-processing techniques. A number of studies demonstrated that ENV cues are associated with speech recognition in quiet, while TFS cues are possibly linked to melody/pitch perception and listening to speech in a competing background. However, there are evidences that recovered ENV from TFS as well as TFS itself may be partially responsible for speech recognition. Current technologies used in cochlear implants (CI) are not efficient in delivering the TFS cues, and new attempts have been made to deliver TFS information into sound-processing strategy in CI. We herein discuss the current updated findings of TFS with a literature review.


Assuntos
Implantes Cocleares , Sinais (Psicologia) , Incêndios , Perda Auditiva , Percepção da Fala
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA