J Postgrad Med ; 1996 Apr-Jun; 42(2): 33-8
Artigo em Inglês | IMSEAR | ID: sea-115276

RESUMO

Forty cases of Austin Moore Replacement done for transcervical fractures of the femur in patients were reviewed after a period of 12 to 48 months postoperatively (mean 26 mth). 30 cases (75%) had mild to severe pain of non-infective origin, starting as early as 6 months postoperatively. This was irrespective of the make, size or position (varus/valgus) of the prosthesis. Though the Aufranc and Sweet clinical scoring was satisfactory in 65% cases, radiological evidence of complications like sinking, protrusion, etc. were seen in majority of the cases. Calcar resorption was seen in 34 cases (85%) as early as 4 months postoperatively. Results of THR and bipolar replacement done for transcervical fractures in recent literature show 85% pain-free cases at 5 years. We feel that Austin Moore Replacement should be reserved for patients more than 65 years of age and those who are less active or debilitated because of other factors, because of increased acetabular wear with time in the younger individual. This is corroborated by unsatisfactory results in patients less than 65 years of age (p < 0.05).


Assuntos
Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Feminino , Fraturas do Colo Femoral/diagnóstico por imagem , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Dor/etiologia , Desenho de Prótese , Falha de Prótese , Amplitude de Movimento Articular , Resultado do Tratamento