Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Laboratory Medicine and Quality Assurance ; : 59-67, 2016.
Artigo em Coreano | WPRIM | ID: wpr-45811

RESUMO

We report here the results of the external quality assessment scheme (EQA) of blood bank tests in Korea carried out in 2015. The proficiency testing specimens used in the survey were prepared at Ajou University Hospital. The response rates from participating laboratories for the first and second trials were 98.7% (542/549) and 98.2% (544/554), respectively. No answers to tests were considered incorrect, and the average accuracy rates for six different test items on the standard survey were as follows: ABO grouping, 99.4% to 100.0%; RhD typing, 99.4% to 100.0%; crossmatching, 93.6% to 99.0%; direct antiglobulin test (DAT) using a polyspecific reagent, 92.9% to 98.3%; DAT using an IgG monospecific reagent, 94.6% to 100.0%; DAT using a C3d monospecific reagent, 84.2% to 98.6%; unexpected antibody screening test, 94.5% to 100.0%; and antibody identification test, 93.8% to 100.0%. We performed a pilot survey on reactivities to A1 (54 responses) and H (50 responses); Rh C, c, E, and e antigen testing (47 responses); and ABO antibody titration (10-34 responses). We obtained excellent results for this EQA, and these results will be helpful for improving or maintaining the quality of the participating laboratories.


Assuntos
Bancos de Sangue , Teste de Coombs , Imunoglobulina G , Coreia (Geográfico) , Ensaio de Proficiência Laboratorial , Programas de Rastreamento
2.
Journal of Laboratory Medicine and Quality Assurance ; : 47-55, 2015.
Artigo em Coreano | WPRIM | ID: wpr-104676

RESUMO

We report here the results of surveys on external quality assessment (EQA) of blood bank tests in Korea carried out in 2014. The proficiency testing specimens were prepared at Ajou University Hospital and the response rates for the 1st and 2nd trials were 94.3% (537/549) and 96.0% (545/554), respectively. No answers were considered incorrect, and the average accuracy rates of six different test items on the regular survey were as follows: ABO grouping, 98.5% to 100.0%; RhD typing, 98.1% to 99.4%; crossmatching, 91.2% to 99.6%; direct antiglobulin test (DAT) using a polyspecific reagent, 96.7% to 98.4%; DAT using an immunoglobulin-G monospecific reagent, 93.8% to 98.7%; DAT using a C3d monospecific reagent, 89.5% to 98.7%; unexpected antibody screening test, 96.2% to 100.0%; and antibody identification test, 69.8% to 100.0%. Test items for the pilot survey were reactivities to anti-A1 and anti-H, Rh subgrouping, and ABO antibody titration. Except for the result of the antibody identification test for specimens with multiple antibodies, we obtained excellent survey results for the EQA of blood bank tests carried out in 2014. In addition, the number of participating institutes was higher in 2014 than in 2013. The EQA of blood bank tests in 2014 should be helpful for improving the quality of the participating laboratories.


Assuntos
Academias e Institutos , Anticorpos , Bancos de Sangue , Teste de Coombs , Coreia (Geográfico) , Ensaio de Proficiência Laboratorial , Programas de Rastreamento
3.
Journal of Laboratory Medicine and Quality Assurance ; : 55-63, 2014.
Artigo em Coreano | WPRIM | ID: wpr-65818

RESUMO

We report here the results of surveys for External Quality Assessment (EQA) of blood bank tests carried out in 2013. The proficiency testing specimens were prepared at Ajou University Hospital and sent to 548 and 545 institutes participating in the 1st and 2nd trial, respectively. Test items for the surveys were ABO grouping, RhD typing, crossmatching, direct antiglobulin test (DAT), antibody screening test, and antibody identification test. The response rates for the 1st and 2nd trials were 94.3% and 96.0%, respectively. No answers were considered incorrect answers, and the average accuracy rates of different test items of the survey were as follows: ABO grouping, 98.9% to 100%; RhD typing, 98.4% to 99.2%; crossmatching, 94.4% to 100.0%; DAT using polyspecific reagent, 94.5% to 99.7%; DAT using IgG monospecific reagent, 94.7% to 98.8%; DAT using C3d monospecific reagent, 91.3% to 98.6%; unexpected antibody screening test, 90.9% to 100%; and antibody identification test, 87.3% to 100.0%. Overall, we obtained excellent survey results for the EQA of blood bank tests carried out in 2013, and the number of participating institutes was higher in 2013 than in 2012.


Assuntos
Academias e Institutos , Bancos de Sangue , Teste de Coombs , Imunoglobulina G , Coreia (Geográfico) , Ensaio de Proficiência Laboratorial , Programas de Rastreamento
SELEÇÃO DE REFERÊNCIAS