Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Tipo de estudo
Intervalo de ano
1.
Asia Oceania Journal of Nuclear Medicine and Biology. 2014; 2 (2): 127-130
em Inglês | IMEMR | ID: emr-167756

RESUMO

Although thallium-201 exercise scintigraphy has been established for the detection of myocardial ischemia and viability, little is known regarding the myocardial thallium-201 kinetics during angioplasty. Herein, we report a 77-year old man with angina pectoris, in whom serial myocardial imaging after a single dose of thallium-201 was helpful in identifying not only the culprit lesion and myocardial viability, but also the dynamic changes in myocardial perfusion during angioplasty. Thallium-201 images after exercise showed a perfusion defect in the inferior wall, with a trivial redistribution 3 hours after the exercise and a marked improvement 24 hours later. Coronary angiography, performed 27 hours after exercise scintigraphy, showed severe stenosis in the right coronary artery. Guidewire crossing of the lesion interrupted the antegrade flow, which was restored after balloon dilation and stent implantation. Thallium-201 images, 2 hours after angioplasty [i.e., 30 hours after exercise], showed a decreased tracer uptake in the inferior wall, which improved the next day [i.e., 48 hours after exercise]. Cardiac biomarkers were negative in the clinical course


Assuntos
Humanos , Masculino , Isquemia Miocárdica/diagnóstico , Tálio/administração & dosagem , Cardiopatias/diagnóstico por imagem , Radioisótopos de Tálio
2.
Journal of the Japanese Association of Rural Medicine ; : 701-706, 2014.
Artigo em Japonês | WPRIM | ID: wpr-375165

RESUMO

  The platelet counts documented in most of the studies using the fully automated hematology analyzer XE-5000 are values measured by impedance technology (PLT-I). If blood specimens showing an anomalous particle-size distribution curve in the area where platelet counts are low are used (exceptionally low platelet count samples), the counting method is automatically switched over to an optical method (PLT-O). In the present study, we examined the usefulness of the XE-5000 by comparing PLT-I with PLT-O, using blood samples with low platelet counts collected from patients who visited our hospital between January 1 and March 31, 2012. Dilution linearity left nothing to be desired in either of the two, but simultaneous reproducibility was higher in PLT-O than in PLT-I. The correlations of PLT-I and PLT-O with visual counts were high, working out at r=0.889~0.984. In the exceptionally low platelet count samples, the correlation coefficient was high in PLT-O than in PLT-I. The cases showing low platelet counts frequently presented giant platelets and/or red cell fragments. Therefore, measuring the samples with low platelet counts requires a high degree of precision. In the samples with exceptionally low platelet counts, PLT-O exceeded PLT-I in simultaneous reproducibility and correlation with visual counts. Thus, our study demonstrated the usefulness of the XE-5000 that could enumerate PLT-O automatically and speedily.

3.
Journal of the Saudi Heart Association. 2013; 25 (3): 231-232
em Inglês | IMEMR | ID: emr-130159
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA