Indian J Physiol Pharmacol ; 2016 Apr-Jun; 60(2): 200-204
Artigo em Inglês | IMSEAR | ID: sea-179560

RESUMO

Study background: Measurement of delivered pharyngeal pressure during continuous positive airway pressure (CPAP) therapy is not in routine practice due to lack of a simple and affordable technique of intrapharyngeal pressure measurement. To overcome the lack of the gold standard solid-state catheter-tip pressure measurement technology in our set up, we improvised a novel method of pressure measurement and tested its validity in a simulated pharynx. Methods: A low-cost pressure transducer was improvised by attaching an orogastric tube to its one end. The other end of the orogastric tube was sealed into an artificial pharynx - a 20 ml syringe. The pressure transducer readings were compared with that obtained by a digital manometer attached to the tip of the syringe. Bland-Altman statistic was used to quantify the measurement reliability of the novel method against the digital manometer. Effect of tube length on the measurement agreement was also studied. The developed technique was applied in new-borns. Results & conclusion: Pressures measured by this technique were in good agreement with that obtained using a digital manometer. This technique has the potential to be used as an alternative to catheter-tip pressure transducers for bedside pharyngeal pressure measurement in new-born babies, especially in underresourced setups.