1.
China Journal of Endoscopy ; (12): 12-16, 2018.
Artigo em Chinês | WPRIM | ID: wpr-702942

RESUMO

Objective To investigate the effectiveness of hemostatic-clip-assisted method during ERCP with ampulla around duodenal diverticulum. Methods 25 patients with ampulla around duodenal diverticulum encountered cannulation difficulty, 11 cases underwent with clip-assisted method, 14 cases with ordinary ways. Number of successful cases, cannulation time, post-operation complication were analyzed. Results All the 11 cases succeeded in clip group. 12 patients succeeded in none-clip group. Cannulation time between the two groups were discrepant. There was no difference in number of successful cases and post-operation complication rate. Conclusion Successful application of hemostatic clip help to expose and facilitate cannulation of an ampulla around a duodenal diverticulum.