1.
Rev. colomb. biotecnol ; 17(1): 79-90, ene.-jun. 2015. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-751192

RESUMO

El ritmo de vida actual, tanto sociocultural como tecnológico, ha desembocado en un aumento de enfermedades y padecimientos que afectan las capacidades físico-motrices de los individuos. Esto ha originado el desarrollo de prototipos para auxiliar al paciente a recuperar la movilidad y la fortaleza de las extremidades superiores afectadas. El presente trabajo aborda el diseño de una estructura mecánica de un exoesqueleto con 4 grados de libertad para miembro superior. La cual tiene como principales atributos la capacidad de ajustarse a la antropometría del paciente mexicano (longitud del brazo, extensión del antebrazo, condiciones geométricas de la espalda y altura del paciente). Se aplicó el método BLITZ QFD para obtener el diseño conceptual óptimo y establecer adecuadamente las condiciones de carga de servicio. Por lo que, se definieron 5 casos de estudio cuasi-estáticos e implantaron condiciones para rehabilitación de los pacientes. Asimismo, mediante el Método de Elemento Finito (MEF) se analizaron los esfuerzos y deformaciones a los que la estructura está sometida durante la aplicación de los agentes externos de servicio. Los resultados presentados en éste trabajo exhiben una nueva propuesta para la rehabilitación de pacientes con problemas de movilidad en miembro superior. Donde el equipo propuesto permite la rehabilitación del miembro superior apoyado en 4 grados de libertad (tres grados de libertad en el hombro y uno en el codo), el cual es adecuado para realizar terapias activas y pasivas. Asimismo, es un dispositivo que está al alcance de un mayor porcentaje de la población por su bajo costo y fácil desarrollo en la fabricación.


The pace of modern life, both socio-cultural and technologically, has led to an increase of diseases and conditions that affect the physical-motor capabilities of persons. This increase has originated the development of prototypes to help patients to regain mobility and strength of the affected upper limb. This work, deals with the mechanical structure design of an exoskeleton with 4 degrees freedom for upper limb. Which has the capacity to adjust to the Mexican patient anthropometry (arm length, forearm extension, geometry conditions of the back and the patient's height) BLITZ QFD method was applied to establish the conceptual design and loading service conditions on the structure. So, 5 quasi-static cases of study were defined and conditions for patient rehabilitation were subjected. Also by applying the finite element method the structure was analyzed due to service loading. The results presented in this work, show a new method for patient rehabilitation with mobility deficiencies in the upper limb. The proposed new design allows the rehabilitation of the upper limb under 4 degrees of freedom (tree degrees of freedom at shoulder and one at the elbow), which is perfect to perform active and passive therapy. Additionally, it is an equipment of low cost, which can be affordable to almost all the country population.

2.
Rev. colomb. biotecnol ; 13(2): 70-83, dic 1, 2011. tab, graf
Artigo em Espanhol | LILACS | ID: lil-645169

RESUMO

Desde los años sesenta se utilizan las señales electromoigráficas (EMG) como señales de control para prótesis actuadas por servomotores, así como en la estimulación de músculos que sufren de parálisis o de atrofia parcial. Mediante el avance tecnológico se ha logrado mejorar el diseño, así como la fabricación de sistemas protésicos, que funcionan como extensiones de algún miembro del cuerpo humano, agregando además con los nuevos diseños, características básicas como: flexibilidad, estética morfológica, incremento de la relación resistencia/peso así como multifuncionalidad. Una prótesis mioeléctrica es una estructura desarrollada con el fin de reemplazar una parte o la totalidad de un miembro del cuerpo humano, lo mismo que suplir las funciones perdidas de este, sin dejar de lado la imagen corporal del paciente. Estas prótesis son accionadas por actuadores que se controlan a través de señales EMG, las cuales se obtiene mediante agujas intramusculares superficiales o por medio de electrodos colocados en el muñón del paciente. Este tipo de prótesis es cada vez más aceptado por personas con amputación de mano, ya que proporciona un mejor desempeño y permite el incremento de funcionalidad para el paciente que la utiliza, debido a que su control es más sencillo.


Since 60’s electromiographical signals (EMG’s) are used like a control signals for prostheses acted by servomotors, as well as stimulation of muscles that are affected due to partial or total paralysis. By means of technological advance, it has been possible to improve the design as well as the production of prosthetic systems that work as extensions of some member of human body, adding with the new designs also basic characteristics as: flexibility, aesthetic morphology, and superior strength/weight relationship, as well as multi-functionality. Mioelectric prosthesis is a structure developed with the purpose of replacing a part or the entirety member of human body, same as to replace the lost functions of this, without leaving aside patient's corporal image. These prostheses are acted by actuators that are controlled through EMG signals, which are obtained by means of intramuscular or superficial needles, or by means of electrodes placed in patient's stump. This class of prostheses is more and more accepted by people with hand amputation since it provides a better acting, that which allows a superior functionality for patient that uses it, because its control is simpler.


Assuntos
Desenho de Prótese/efeitos adversos , Desenho de Prótese/métodos , Desenho de Prótese/mortalidade , Desenho de Prótese/normas , Análise de Falha de Equipamento/estatística & dados numéricos , Análise de Falha de Equipamento/instrumentação , Análise de Falha de Equipamento/métodos , Análise de Falha de Equipamento/normas
3.
Rev. colomb. biotecnol ; 12(2): 41-54, dic. 2010. ilus
Artigo em Espanhol | LILACS | ID: lil-590773

RESUMO

En México, la mortalidad debido a enfermedades bronco-respiratorias se ubica en el sexto lugar según datos estadísticos dados por el Instituto Nacional de Enfermedades Respiratorias (INER). Esto genera la necesidad de incrementar la eficiencia en la aplicación de los tratamientos usados para este tipo de patología. Algunos de los métodos utilizados con mayor frecuencia para el tratamiento de estas dolencias hacen uso de micro dispositivos, también conocidos como válvulas endobronquiales. Este es un sistema alternativo que evita cirugías invasivas y logra prolongar e incrementar la calidad de vida de los pacientes. En este trabajo se presenta el análisis del desempeño de la válvula IBV®. Para el desarrollo del estudio numérico se determinaron las dimensiones y propiedades mecánicas del modelo a partir de catálogos del fabricante. Se desarrolló un modelo para el cual se consideraron las propiedades del Nitinol® y Silastic®. Asimismo, se propusieron dos condiciones de operación para la válvula, una anclada en el bronquio y la otra en la condición en la que se encuentra plegada dentro del broncoscopio. Se utilizó el Método del elemento finito (MEF) para simular las condiciones de trabajo de la válvula. Los resultados encontrados muestran el funcionamiento estructural y el nivel de los esfuerzos generados en el implante durante el ciclo de respiración forzada del individuo. Además, se proporcionan las bases para generar un nuevo dispositivo que pueda emular el funcionamiento de este tipo de implantes y aumente la eficiencia del tratamiento de dicha patología.


In Mexico, the mortality rate due to bronchial respiratory sickness is placed in the sixth position, according to statistics from the National Institute of Breathing Sickness (INER), so it is convenient to increment the efficiency of treatments for those pathologies. The intrabronchial valve is a recommended alternative method; being it main objective to avoid invasive surgery and increase the time and quality of patient´s life. Within this work a biomechanical analysis of an IBV® valve is carried out. Regarding the numerical analysis, the dimensions and mechanical properties of the valve were proposed based on catalogues published by the manufacturer as more reliable information was not available in the open literature. As a result, a new model was developed in which both materials Nitinol® and Silastic® are considered as the main valve materials. The proposed working conditions assume that the valve is implanted in folded form at the bronchus and then anchored when it is unfolded. Finite Element Method (FEM) was used to simulate the proposed working conditions. Results obtained show the structural performance and the level of stress generated in the implant during the breathing cycle. In addition, it provides the knowledge to generate a new device that could emulate the performance of these implants and develop a more efficient treatment this disease.


Assuntos
Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/enfermagem , Neoplasias Pulmonares/epidemiologia , Neoplasias Pulmonares/fisiopatologia , Neoplasias Pulmonares/induzido quimicamente , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/química , Neoplasias Pulmonares/tratamento farmacológico , Valvas Cardíacas/anormalidades , Valvas Cardíacas/fisiologia , Valvas Cardíacas/imunologia , Valvas Cardíacas/patologia , Valvas Cardíacas/química