Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Braz. j. infect. dis ; 19(4): 358-362, July-Aug. 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-759284

RESUMO

Background: Human parainfluenza viruses account for a significant proportion of lower respiratory tract infections in children.Objective: To assess the prevalence of Human parainfluenza viruses as a cause of acute respiratory infection and to compare clinical data for this infection against those of the human respiratory syncytial virus.Methods: A prospective study in children younger than five years with acute respiratory infection was conducted. Detection of respiratory viruses in nasopharyngeal aspirate samples was performed using the indirect immunofluorescence reaction. Length of hospital stay, age, clinical history and physical exam, clinical diagnoses, and evolution (admission to Intensive Care Unit or general ward, discharge or death) were assessed. Past personal (premature birth and cardiopathy) as well as family (smoking and atopy) medical factors were also assessed.Results: A total of 585 patients were included with a median age of 7.9 months and median hospital stay of six days. No difference between the HRSV+ and HPIV+ groups was found in terms of age, gender or length of hospital stay. The HRSV+ group had more fever and cough. Need for admission to the Intensive Care Unit was similar for both groups but more deaths were recorded in the HPIV+ group. The occurrence of parainfluenza peaked during the autumn in the first two years of the study.Conclusion: Parainfluenza was responsible for significant morbidity, proving to be the second-most prevalent viral agent in this population after respiratory syncytial virus. No difference in clinical presentation was found between the two groups, but mortality was higher in the HPIV+ group.


Assuntos
Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Vírus da Parainfluenza 1 Humana/isolamento & purificação , Infecções por Vírus Respiratório Sincicial/virologia , Infecções Respiratórias/virologia , Infecções por Respirovirus/epidemiologia , Doença Aguda , Brasil/epidemiologia , Hospitalização , Nasofaringe/virologia , Estudos Prospectivos , Infecções Respiratórias/epidemiologia , Estações do Ano
2.
J. bras. patol. med. lab ; 50(4): 272-277, Jul-Aug/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-723972

RESUMO

Introduction: The antibodies have an important role in the serodiagnosis, constituting the most widely used biomarkers to detect and confirm various diseases. Objective: To investigate the reproducibility of anti-human immunodeficiency virus (HIV) antibodies reactivity, to assess the stability of the sera samples stored at -20ºC for two to eighteen years. Method: Sera were collected in the period 1988-2004 for routine anti-HIV antibodies diagnostic testing. The remaining samples stored at -20ºC, were analyzed in this study. Serum sample stability was assessed by enzyme-linked immunosorbent assay/enzyme immunoassay (ELISA/EIA), indirect immunofluorescence assay (IFA), and Western blot (WB) for detecting anti-HIV antibodies. The previously found results (1988-2004) and those obtained in 2006 were subjected to Kappa index analysis. Result: In the period 1988-to 2004, the degree of concordance of the ELISA/EIA, IFA and WB results were considered, good (k = 0.80), regular (k = 0.35), and good (k = 0.63), respectively. Conclusion: Regarding HIV serologic test, the serum samples were stable for 18 years in ELISA/EIA and for 4 years in IFA technique, however, for the WB methodology it was not possible to determine the time of stability of the anti-HIV antibodies...


Introdução: Os anticorpos possuem papel fundamental no sorodiagnóstico e constituem os mais difundidos biomarcadores empregados na detecção e na confirmação de diversas doenças. Objetivo: Verificar a reprodutibilidade dos resultados de anticorpos contra o vírus da imunodeficiência humana (HIV) para avaliar a estabilidade dos soros armazenados a -20ºC durante período de dois a dezoito anos. Método: Os soros utilizados foram provenientes de amostras remanescentes da rotina diagnóstica para detecção de anticorpos anti-HIV, no período de 1988 a 2004, os quais estavam armazenados em freezer a -20ºC. A estabilidade das amostras de soro foi avaliada por meio de enzyme-linked immunosorbent assay/enzyme immunoassay (ELISA/EIA), imunofluorescência indireta (IFI) e Western blot (WB) para detecção de anticorpos anti-HIV, e os resultados dos testes realizados anteriormente (1988-2004) e os obtidos em 2006 foram submetidos à análise do índice Kappa. Resultado: No período de 1988-2004, os graus de concordância dos resultados do ELISA/EIA, IFI e WB foram considerados, respectivamente, bom (k = 0,80), regular (k = 0,35) e bom (k = 0,63). Conclusão: No que diz respeito à sorologia para HIV, as amostras de soro foram estáveis por 18 anos no ELISA/EIA e por quatro anos na técnica de IFI, no entanto, para a metodologia de WB, não foi possível determinar o tempo de estabilidade dos anticorpos anti-HIV...


Assuntos
Humanos , Bancos de Sangue , Anticorpos Anti-HIV , Reatividade-Estabilidade , Soro , Ensaio de Imunoadsorção Enzimática , Fatores de Tempo
3.
J. bras. patol. med. lab ; 50(1): 46-52, 02/2014. tab
Artigo em Inglês | LILACS | ID: lil-704694

RESUMO

Introduction: The present study reports the data from the first homogeneity assessment of samples composing the serum panels produced at the Immunology Center of Instituto Adolfo Lutz, São Paulo. These samples have been distributed to the public laboratories and those partaking in the Brazilian Unified Health System, and to the participants in the Internal Quality Control Program for human immunodeficiency virus (HIV) antibody (Ab) testing. Objective: To assess the homogeneity of serum samples in panels from different lots for HIV/acquired immunodeficiency syndrome (AIDS) immunodiagnosis by using the statistical method to ensure quality of the reference material. Method: Sera homogeneity was evaluated by means of enzyme-linked immunoassay/enzyme immunoassay (ELISA/EIA) for detection of HIV Ab, and the one-way analysis of variance was employed for analyzing the data. No statistically significant differences were found among the several serum vials. Conclusion: The sera dispensed in the vials were homogeneous in the respective lots...


Introdução: No presente estudo estão descritos os resultados das primeiras análises feitas sobre a avaliação da homogeneidade das amostras componentes de painéis de soros produzidos no Centro de Imunologia do Instituto Adolfo Lutz e distribuídos aos laboratórios públicos e conveniados ao Sistema Único de Saúde e participantes do Programa de Controle de Qualidade Interno para imunodiagnóstico de vírus da imunodeficiência humana/síndrome da imunodeficiência adquirida (HIV/AIDS). Objetivo: Avaliar a homogeneidade das amostras de soro componentes de painéis de diferentes lotes para imunodiagnóstico de HIV/Aids por meio de método estatístico para garantir a qualidade do material de referência. Material e método: A homogeneidade das amostras de soro foi avaliada por meio de enzyme-linked immunoassay/enzyme immunoassay (ELISA/EIA) para detecção de anticorpos anti-HIV, e os resultados foram submetidos à análise de variância fator único. Não foram encontradas diferenças significativas entre os resultados obtidos para os diversos frascos de soro. Conclusão: As amostras distribuídas nos frascos foram homogêneas entre si nos respectivos lotes...


Assuntos
Humanos , Soro , Sorodiagnóstico da AIDS/normas , Técnicas Imunoenzimáticas/normas , Testes Imunológicos/normas , Controle de Qualidade , Padrões de Referência
4.
J. bras. patol. med. lab ; 50(1): 36-45, 02/2014. tab
Artigo em Inglês | LILACS | ID: lil-704696

RESUMO

Introduction: The use of reference materials in order to assure and perform the quality control of analytical measurements is a requirement in clinical laboratories. Objectives: Stability of serum samples, kept frozen at -20°C for long-term storage and at varied temperatures during short periods, was evaluated by investigating the persistency of anti-human immunodeficiency virus (HIV) antibodies reactivity on enzyme-linked immunosorbent assay/enzyme immunoassay (ELISA/EIA), Western blot and indirect immunofluorescence assays. Method: The analyzed sera were part of serum panels (comprised of anti-HIV positive and negative samples), produced at the Immunology Center of Instituto Adolfo Lutz, which have been the reference specimens for producing the internal quality assurance sera of HIV/acquired immunodeficiency syndrome (AIDS) immunodiagnostic assays. Sera stability was assessed in samples stored at -20°C for 56 weeks, and at various temperature conditions: from 2°C to 8°C (refrigerator), from 15°C to 25°C (room temperature), at 37°C (incubator) and at -80°C (freezer) for 24 and 48 hours. The statistical analyses on HIV-negative serum samples (long-term storage) were significant (p < 0.05), and neither adverse effects on these samples as the occurrence of false-positive results nor false-negative results in HIV antibody positive sera were found in both studies. Conclusion: It was possible to conclude that the reference material remained stable for 48 hours at different temperatures (short-term) and it remained stable at -20°C for 56 weeks (long-term)...


Introdução: A utilização de materiais de referência para assegurar e desempenhar o papel de controle de qualidade das medições analíticas é requisito em laboratórios clínicos. Objetivo: O presente estudo avaliou a estabilidade das amostras de soro, armazenadas a -20°C por um longo período de tempo e durante curto prazo em diferentes temperaturas, quanto à invariabilidade da reatividade de anticorpos contra o vírus da imunodeficiência humana (HIV), por meio de enzyme-linked immunosorbent assay/enzyme immunoassay (ELISA/EIA), Western blot e imunofluorescência indireta. Método: As amostras analisadas foram provenientes de painéis de soros (constituídos de amostras anti-HIV positivo e negativo), produzidos no Centro de Imunologia do Instituto Adolfo Lutz (IAL), os quais têm sido material de referência para o preparo de amostras do controle de qualidade interno de testes imunodiagnósticos de HIV/síndrome da imunodeficiência adquirida (AIDS). A avaliação da estabilidade dos soros foi efetuada em amostras armazenadas a -20°C por 56 semanas e nas diferentes condições de temperaturas: de 2°C a 8°C (geladeira), de 15°C a 25°C (ambiente), 37°C (estufa) e -80°C (freezer), durante 24 e 48 horas. Os resultados das análises de tendência das amostras de soro HIV negativo (armazenamento de longo prazo) foram significantes (p < 0,05) e nenhum efeito adverso foi observado nessas amostras, como a ocorrência de resultados falso-positivos, tampouco foram detectados resultados falso-negativos em amostras de soro positivas para detecção de anticorpos anti-HIV em ambas as avaliações. Conclusão: Foi possível concluir que o material de referência manteve-se estável por 48 horas nas diferentes temperaturas (curto prazo) e permaneceu estável a -20°C por 56 semanas (longo prazo)...


Assuntos
Humanos , Temperatura Baixa , Anticorpos Anti-HIV , Temperatura Alta , Controle de Qualidade , Reatividade-Estabilidade , Soro , Temperatura
5.
J. bras. patol. med. lab ; 48(6): 409-414, dez. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-666028

RESUMO

INTRODUÇÃO: A utilidade da detecção de anticorpos da imunoglobulina da classe M (IgM) no diagnóstico da sífilis tem sido discutida há tempos. OBJETIVO: No presente estudo foi analisada a ocorrência de anticorpo IgM anti-T. pallidum (Tp-IgMAc) nas amostras de pacientes com sífilis recente, na fase de soroconversão e no monitoramento da resposta sorológica pós-tratamento. MÉTODOS: Amostras séricas de 11 indivíduos. RESULTADOS: Na soroconversão, o Tp-IgMAc foi detectado nas amostras de 10 indivíduos, e em um paciente a reatividade IgM ocorreu anteriormente ao Venereal Disease Research Laboratory (VDRL). A sororreversão foi evidenciada nas amostras de três pacientes com sífilis secundária tratada, e em um indivíduo com reinfecção. CONCLUSÃO: A detecção de Tp-IgMAc mostrou ser um potencial marcador diagnóstico de sífilis ativa e o desempenho do ensaio imunoenzimático de captura de IgM (ELISA-IgM) para o monitoramento pós-tratamento foi similar ao da VDRL.


INTRODUCTION: The appropriateness of IgM antibody detection in the diagnosis of syphilis has been extensively discussed. OBJECTIVE: This study aimed at assessing the detection of anti-T. pallidum IgM antibody (TP-IgMAb) in serum samples from patients with recent syphilis in seroconversion and in the monitoring of post-treatment serological response. METHODS: Serum samples from 11 individuals. RESULTS: At seroconversion, positive Tp-IgMAb was detected in 10 samples and IgM reactivity previous to Venereal Disease Research Laboratory (VDRL) was detected in one sample. Seroreversion was found in samples from three treated patients with secondary syphilis and in one individual with reinfection. CONCLUSION: Tp-IgMAb detection proved to be a potential diagnostic marker for active syphilis, and IgM capture enzyme linked immunosorbent assay (ELISA-IgM) performance was similar to VDRL in post-treatment monitoring.

6.
Rev. Inst. Adolfo Lutz ; 71(3): 573-581, jul.-set. 2012. tab, graf
Artigo em Português | LILACS, SES-SP, SESSP-CTDPROD, SES-SP, SESSP-ACVSES, SESSP-IALPROD, SES-SP, SESSP-IALACERVO | ID: lil-696270

RESUMO

No presente estudo foi investigado o impacto dos múltiplos ciclos de congelamento e descongelamento na estabilidade das amostras de soro estocadas a -20 °C quanto à reatividade de anticorpos anti-HIV. As amostras analisadas foram provenientes de painéis de soros (constituídos de amostras anti-HIV positivo e negativo), produzidos no Centro de Imunologia – Instituto Adolfo Lutz (IAL), os quais têm sido material de referência para o preparo de amostras do controle de qualidade interno de testes imunodiagnósticos de HIV/Aids. A avaliação da estabilidade dos soros foi efetuada por meio de ELISA/EIA, Western blote imunofluorescência indireta, em amostras submetidas a 11 consecutivos ciclos de congelamento e descongelamento, que variaram de 7 a 60 ciclos. Nenhum efeito estatisticamente significante na reatividade dos anticorpos específicos foi observado. Portanto, o procedimento de congelamento e descongelamento, em até 60 ciclos, não causou efeitos adversos na reatividade das amostras de soro positivas para detecção de anticorpos anti-HIV, sem ocorrência de reações falso-negativas, tampouco de resultados falso-positivos em amostras negativas para HIV.


Assuntos
Anticorpos Anti-HIV , Congelamento , Soro , Temperatura , Ensaio de Imunoadsorção Enzimática
7.
Rev. Inst. Adolfo Lutz ; 69(2): 157-164, abr.-jun. 2010. tab
Artigo em Inglês | LILACS, SES-SP, SESSP-CTDPROD, SES-SP, SESSP-ACVSES, SESSP-IALPROD, SES-SP, SESSP-IALACERVO | ID: lil-571143

RESUMO

The present study reports the data resulted from the first evaluation on the performance of the laboratory units of the HIV/AIDS Diagnosis Laboratory Network of the State of São Paulo, which have agreed to participate in the Internal Quality Control scheme for HIV antibody testing (HIV-IQC) at the respective routine diagnostic services. From April 2009 to February 2010, the HIV-IQC serum panels were distributed to 37 laboratories of the Sub-Network of São Paulo State. Of these, 27 (73.0%) sent the forms back to the IAL-Central Lab with the achieved results from the IQC in HIV EIA/ELISA kits. Among 22 (59.5%) laboratories, which perform additional HIV antibody testing by indirect immunofluorescence-based assay (HIV-IFA), 11 (50.0%) carried out the HIV-IFA IQC. As identical data were reported from procedures by employing the IQC samples in different batches of EIA/ELISA kits from the same manufacturers, it may inferred that the laboratories have complied with the recommended procedures, and that the standardized conduct has been followed. Furthermore, the analyses on reported results indicated that the majority of commercial diagnostic kits used for routine HIV antibody testing at the Network laboratories show good quality and reproducibility.


No presente estudo estão descritos os resultados das primeiras análises feitas quanto ao desempenho das unidades componentes da Rede de Laboratórios de Diagnóstico de HIV/AIDS do Estado de São Paulo, que concordaram em participar da implantação do controle de qualidade interno para o diagnóstico sorológico da infecção pelo HIV (CQI-HIV) nos respectivos serviços referentes à detecção de anticorpos anti-HIV. De abril de 2009 a fevereiro de 2010 foram distribuídos os painéis de soro CQI-HIV para 37 laboratóriosda sub-rede do Estado de São Paulo. Desses, 27 (73,0%) enviaram ao IAL Central os formulários com os resultados obtidos no CQI-HIV para EIA/ELISA. Entre os 22 (59,5%) laboratórios que realizam também oensaio de IFI HIV-1 na rotina diagnóstica, 11 (50,0%) executaram o sistema CQI para esse teste. Em vistados laboratórios participantes terem apresentado idênticos dados na determinação de reatividade ideal dasamostras do painel para os conjuntos diagnósticos procedentes de mesmas firmas produtoras e de diferenteslotes, pode-se inferir que os laboratórios seguiram os procedimentos preconizados, o que demonstra aadequada execução da conduta padronizada. Ademais, a análise dos resultados obtidos indica que osconjuntos diagnósticos utilizados pela rede de laboratórios são de boa qualidade e de boa reprodutibilidade.


Assuntos
Sorodiagnóstico da AIDS , Anticorpos Anti-HIV , Infecções por HIV , Controle de Qualidade
8.
Braz. j. infect. dis ; 12(6): 476-479, Dec. 2008. graf, tab
Artigo em Inglês | LILACS | ID: lil-507445

RESUMO

The purpose of this study was to identify the rate of infections due to RSV and other viruses in children. In addition we have analyzed demographic data and clinical characteristics of the RSV-positive patients comparing with patients infected by other respiratory viruses. We also described the seasonality of the RSV occurrence in a hospital in São Paulo. Children below 5 years old admitted in Santa Casa de São Paulo Hospital between February 2005 and September 2006 due to acute respiratory infections (ARI) were included. A nasopharyngeal specimens were obtained with sterile No. 5 French feeding catheters as soon as possible (usually within 24 h). Specimens were kept refrigerated at 4ºC and transported to Adolfo Lutz Institute, where the indirect immunofluorescent assay was performed. Virus identified by these assay included RSV, Adenovirus, Influenza A and B virus and Parainfluenza 1, 2, and 3. Clinical data from each group was compared. Four hundred and fifty five cases were included in the study, with 30 percent positive for some type of virus. Viruses that were identified included Respiratory Syncytial Virus (73.03 percent), Influenza (8.42 percent), Parainfluenza (8.42 percent) and Adenovirus (3.37 percent). We divided the subjects in 3 groups: Group 1 RSV-Positive, Group 2 Other Positive Viruses and Group 3 Negative for Respiratory Virus. Mean age (months) was of 7.5 for RSV-positive children, 7.6 for other viruses, and 8 for negative for respiratory virus. The RSV-Positive Group was significantly younger than the Group Negative for Respiratory Virus (p<0.05). Signs of UAI were more present in the Positive RSV Group (p<0.05). General mortality was of 2.41 percent. There was a higher incidence of RSV between the months of March and August in the two years of the study. Our study indicates RSV as the most prevalent viral agent in children admitted due to (ARI), especially in infants below 3 months old. We have also found that infections...


Assuntos
Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Infecções por Vírus Respiratório Sincicial/epidemiologia , Infecções Respiratórias/virologia , Brasil/epidemiologia , Hospitalização , Incidência , Nasofaringe/virologia , Estudos Prospectivos , Infecções Respiratórias/epidemiologia , Estações do Ano
9.
Cad. saúde pública ; 22(9): 1979-1987, set. 2006. tab, graf
Artigo em Português | LILACS | ID: lil-433350

RESUMO

A deficiência de vitamina A constitui um problema de saúde pública no Nordeste brasileiro. O objetivo deste estudo foi determinar a prevalência da deficiência de vitamina A e os fatores associados em pré-escolares de Teresina, Piauí, Brasil. Os níveis de retinol sérico foram determinados por HPLC, e foram investigadas as características sócio-econômicas e demográficas de 631 crianças com idade de 36 a 83 meses. Investigou-se a associação entre os níveis de retinol e as variáveis de interesse por análise de regressão linear uni e multivariada. O nível médio de retinol foi de 1,21mmol/L (IC95 por cento: 1,17-1,25µmol/L), independente do sexo (p = 0,259). A hipovitaminose A (retinol < 0,69µmol/L) foi observada em 15,4 por cento das crianças (IC95 por cento: 12,7-18,4), com tendência à diminuição com o avanço da idade; 29 por cento das crianças (IC95 por cento: 25,2-32,4) tinham valores aceitáveis de retinol, mas não adequados (0,70 a 1,04µmol/L). Encontrou-se associação positiva entre níveis de retinol e idade, renda per capita, suplementação prévia com vitamina A e escolaridade materna. A prevalência de hipovitaminose A representa um problema moderado de saúde pública, ressaltando a importância das estratégias de combate a essa carência na região.


Assuntos
Humanos , Pré-Escolar , Deficiência de Vitamina A/epidemiologia , Vitamina A/administração & dosagem , Cromatografia Líquida de Alta Pressão , Prevalência , Análise de Regressão , Fatores Socioeconômicos
10.
Rev. Inst. Med. Trop. Säo Paulo ; 45(6): 319-322, Nov.-Dec. 2003. tab
Artigo em Inglês | LILACS | ID: lil-353982

RESUMO

A rapid test based on an immunochromatography assay - DetermineÕ Syphilis TP (Abbott Lab.) for detecting specific antibodies to Treponema pallidum was evaluated against serum samples from patients with clinical, epidemiological and serological diagnosis of syphilis, patients with sexually transmitted disease other than syphilis, and individuals with negative serology for syphilis. The DetermineÕ test presented the sensitivity of 93.6 percent, specificity of 92.5 percent, and positive predictive value and negative predictive value of 95.2 percent and 93.7 percent, respectively. One serum sample from patient with recent latent syphilis showed a prozone reaction. DetermineÕ is a rapid assay, highly specific and easy to perform. This technique obviates the need of equipment and its diagnostic features demonstrate that it may be applicable as an alternative assay for syphilis screening under some emergency conditions or for patients living in remote localities.


Assuntos
Humanos , Anticorpos Antibacterianos , Cromatografia , Testes Imunológicos , Sífilis , Treponema pallidum , Estudo de Avaliação , Valor Preditivo dos Testes , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade , Fatores de Tempo
11.
RBCF, Rev. bras. ciênc. farm. (Impr.) ; 38(4): 487-497, out.-dez. 2002. tab, graf
Artigo em Português | LILACS | ID: lil-334637

RESUMO

O treinamento intenso e o exercício exaustivo podem ocasionar imunossupressão em atletas por meio da diminuição da concentração plasmática de glutamina. O presente estudo verificou inicialmente o efeito da suplementação com L-glutamina e L-alanil-L-glutamina sobre a resposta ao teste de hipersensibilidade do tipo tardio (HTT) em ratos submetidos ao treinamento intenso em natação durante seis semanas. Posteriormente, foi avaliado o efeito dessas intervenções nutricionais sobre a contagem total e porcentual de leucócitos e concentração sérica de anticorpos IgG anti-albumina de soro bovino, em animais submetidos ao teste de exaustão e recuperados durante o período de 3 horas...


Assuntos
Animais , Ratos , Exercício Físico/fisiologia , Glutamina , Hipersensibilidade Tardia , Sistema Imunitário , Ciências da Nutrição , Fenômenos Fisiológicos da Nutrição do Lactente , Coleta de Amostras Sanguíneas , Contagem de Leucócitos , Avaliação Nutricional , Radioimunoensaio
12.
J. bras. patol ; 36(3): 161-5, jul.-set. 2000. ilus, tab
Artigo em Português | LILACS | ID: lil-275803

RESUMO

A sífilis ainda é um problema de saúde pública, apesar dos esforços empreendidos para a sua prevençäo e a existência de tratamento eficiente. Os testes sorológicos säo fundamentais para o diagnóstico da doença. O presente trabalho descreve um novo teste de immunoblot )IB-rTp), utilizando três antígenos recombinantes de Treponema pallidum (GST-rTp47, GST-rTp17 e GST-rTp15), além da glutathiona S-tranferase (GST) purificada. FOram testadas 114 amostras séricas (53 de pacientes com sífilis, 50 de indivíduos sadios e 11 de pacientes com outras doenças) verificou-se concordância de 100 por cento em o IB-rTp e os testes treponêmicos convencionais, que utilizam antígeno nativo. A reatividade, quando presente, foi especificada contra a fraçäo treponêmica de cada proteína de fusäo. O teste IB-rTp apresentou alta especificidade; é de fácil execuçäo, näo requerendo absorçäo prévia do soro, sendo de utilidade como teste confirmatório de sífilis


Assuntos
Antígenos de Bactérias/imunologia , Sorodiagnóstico da Sífilis , Treponema pallidum/imunologia , Técnicas Imunoenzimáticas , Proteínas Recombinantes
13.
Rev. Inst. Med. Trop. Säo Paulo ; 41(2): 115-8, mar.-abr. 1999. tab
Artigo em Inglês | LILACS | ID: lil-236053

RESUMO

Os antigenos recombinantes de Treponema pallidum GST-rTp47, GST-rTp17 e GST-rTp15, produzidos em fusao com glutationa S-transferase (GST) em E. coli, foram analisados quanto ao potencial diagnostico da sifilis pela tecnica de Western blotting. Foram testadas 53 amostras, sendo 25 pacientes em diferentes estagios clinicos da sifilis, com resultados positivos no teste treponemico classico; 25 amostras procedentes de doadores de banco de sangue, com sorologia negativa e 3 de pacientes com doenca sexualmente transmissivel nao relacionado a sifilis. Todas as amostras de pacientes com sifilis apresentaram alta reatividade com o antigeno GST-rTp17...


Assuntos
Humanos , Western Blotting , Sífilis/diagnóstico , Treponema pallidum/imunologia , Doadores de Sangue , Eletroforese em Gel de Poliacrilamida , Proteínas Recombinantes/imunologia , Padrões de Referência , Sensibilidade e Especificidade , Testes Imunológicos/métodos
15.
An. bras. dermatol ; 65(3): 105-10, mar.-jun. 1990. tab
Artigo em Português | LILACS | ID: lil-87875

RESUMO

A literatura médica, no Brasil, registra rasos casos de paracoccidioidomicose em pacientes aidéticos (Bernard et al., em publicaçäo; Carnaúba et al.; Pedro et al; Goldani et al. e Bakos et al. totalizando 7 (sete) observaçöes, publicadas ou comunicadas em congressos. Esta ocorrência contrasta com a grande freqüência de candidíase (incluindo formas profundas), criptococose e histoplasmose, associadas a infecçäo pelo vírus HIV. Tal fato talves possa ser explicado por ser a AIDS síndrome infecciosa predominante urbana e a paracoccidioidomicose doença essencialmente de zonas rurais. Em soros de 50 pacientes com paracoccidioidomicose, 40 do sexo masculino (80%) e 10 do sexo feminino (20%) foram pesquisados anticorpos HIV-1 pela técnica ELISA e, em 19 casos limítrofes (38%) foi realizado teste confirmatório, pela técnica de Western-blot. Somente em um caso de paracoccidioidomicose foram detectados anticorpos específicos HIV-1 em 5 pacientes (10%) foram revelados anticorpos, provavelmente inespecíficos, anti-p24; gp160 em 3 casos (6%); gpl120 em dois casos (4%); e gp3 em um caso (2%). Dos sete soros de pacientes com bandas consideradas inespecíficas, repetidas as provas sorológicas para AIDS, com amostras colhidas alguns meses após (ver dados anexos), apenas em 1 foram registrados resultados positivos, com faixas de baixa intensidade. Tais pacientes, examinados na época, näo apresentaram nenhuma manifestaçäo clínica de AIDS ou de pré-AIDS


Assuntos
Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Humanos , Masculino , Feminino , HIV/análise , Paracoccidioidomicose/complicações , Síndrome da Imunodeficiência Adquirida/complicações , Western Blotting , Brasil , População Rural
16.
Rev. Inst. Med. Trop. Säo Paulo ; 32(3): 204-10, maio-jun. 1990. tab
Artigo em Inglês | LILACS | ID: lil-103596

RESUMO

Realzou-se inquérito soroepidemiológico, para detecçäo de anticorpos anti-Toxocara, em 2.025 soros de indivíduos residentes em cinco municípios do Estado de Säo Paulo (Säo Paulo, Campinas, Santos, Marília e Presidente Prudente), através de técnica imunoenzimática (ELISA) e emprego de antígenos obtidos a partir de larvas de 2§ - 3§ estádio de Toxocara canis. Após absroçäo com extratos de Ascaris lumbricoides, revelou-se a presença de anticorpos anti-Toxocara, em níveis significativos, em 3,60% dos soros examinados, com predominância de indivíduos com idade inferior a 15 anos (6,41%). Observou-se, ainda, tendência a ocorrerem índices mais elevados de infecçäo por larvas de Toxocara entre indivíduos residentes em municípios com maior densidade demográfica (Säo Paulo, Campinas e Santos), especialmente no grupo com menos de 15 anos de idade


Assuntos
Humanos , Masculino , Feminino , Anticorpos Anti-Helmínticos/análise , Larva Migrans Visceral/epidemiologia , Toxocara/imunologia , Brasil/epidemiologia , Ensaio de Imunoadsorção Enzimática , Larva Migrans Visceral/transmissão , Prevalência , Fatores de Risco
17.
Rev. Inst. Adolfo Lutz ; 50(1/2): 285-90, 1990. tab
Artigo em Inglês | LILACS, SES-SP | ID: lil-100214

RESUMO

The present study investigates the number of immunoregulatory cells in 55 patients suspected of Acquired Immunodeficiency Syndrone(AIDS) associated with cytomegalovirus(CMV) infection. Patients were divided into three groups: RISK(13 cases), LAS/ARC(21 cases) and AIDS(21 cases) according to epidemiological and clinical findings and using CDC criteria. The CMV infection was suggested based on clinical and serological evaluations. No significant difference in CMV seropositivity was observed among the groups (66,7% to 77,0%), althougha diminished number of cases 3 (14,3%) with CMV-IgM antibody was detected in AIDS group. Phenotypic analysis of leukocytes, lymphocytes and lymphocyte subsets was realized. The results obtained were similar between CMV-seropositive and CMV-seronegative patients in each group studied. On the other hand, the number of T lymphocytes and T helper/inducer lymphocytes were markedly diminished in the LAS/ARC and AIDS groups. The number of T suppressor/cytotoxic lymphocytes was increased in all groups analysed. These alterations in T lymphocyte subsets are responsible for the reversal ratio observed in these patients.


Assuntos
Complexo Relacionado com a AIDS , Citomegalovirus , Síndrome da Imunodeficiência Adquirida
18.
Rev. Inst. Adolfo Lutz ; 49(1): 101-6, jun. 1989. tab
Artigo em Português | LILACS, SES-SP | ID: lil-81157

RESUMO

Foram processadas 1.050 amostras de soro e/ou líquido cefalorraquidiano (LCR) de 450 pacientes do Estado de Säo Paulo com pesquisa positiva para anticorpos anti-HIV. Foi estudada a prevalência de anticorpos anti-Toxoplasma gondii através da reaçäo de imunofluorescência indireta nesses pacientes. Foram dosados anticorpos anti-T. gondii das classes Igtotal e IgM específico. Os resultados revelaram positividade par Igtotal nas amostras de soro e LCR em 69,1% e 47,3%, respectivamente. Em relaçäo às imunoglobulinas IgM, a sorologia mostrou-se positiva em 2,8% das amostras. Observou-se ainda elevada reatividade para Igtotal em amostras de LCR (61,2%) em pacientes com quadro clínico compatível com toxoplasmose. A concomitância de positividade em amostras de soro e LCR mostrou-se crescente, quanto mais avançada a fase clínica em que os pacientes com SIDA (AIDS) se encontravam. Em pacientes do grupo IV (ARC) da SIDA, quando os títulos de Igtotal no soro sanguíneo foram>/1.024, a concomitância de positividade no LCR foi de 80%..


Assuntos
Toxoplasmose , Imunofluorescência , Síndrome da Imunodeficiência Adquirida
19.
Rev. Inst. Med. Trop. Säo Paulo ; 30(5): 379-82, set.-out. 1988. tab
Artigo em Português | LILACS | ID: lil-64989

RESUMO

Investigou-se o papel do contacto com cäes no domicílio e na atividade profissional como fatores de risco para transmissäo de larvas de Toxocara sp. a seres humanos, acarretando a síndrome de larva migrans visceral. Através de técnica imunoenzimática (E.L.I.S.A.) pesquisou-se a presença de anticorpos anti-Toxocara no soro de 79 mulheres adultas, residentes no município de Säo Paulo, que possuíam, ou possuíram nos dois últimos anos, cäes em seus domicílios e de 123 homens adultos, funcionários da Prefeitura Municipal de Säo Paulo, encarregados da captura de cäes vadios e de sua manutençäo em canis. Como controles utilizaram-se os soros de 205 mulheres adultas que näo possuíram, nos dois últimos anos, cäes em suas casas e de 139 homens adultos, cuja atividade profissional näo os obrigava a manter contacto com cäes. Os resultados indicaram que, nas condiçöes do presente trabalho, a posse de cäes no domicílio constitui fator de risco para transmissäo de larvas de Toxocara a seres humanos, ao contrário do verificado para o contacto profissional com cäes


Assuntos
Cães , Larva Migrans Visceral/transmissão , Anticorpos Anti-Helmínticos/análise , Toxocara/imunologia
20.
Rev. Inst. Med. Trop. Säo Paulo ; 30(2): 95-100, mar.-abr. 1988. tab
Artigo em Português | LILACS | ID: lil-53308

RESUMO

Foi avaliado o teste imunoenzimático (ELISA), para detecçäo de anticorpos da classe IgM na leptospirose humana. Nas amostras de soros analisadas, o teste ELISA demonstrou ser mais sensível, específico e precoce, quando comparado ao teste de soroaglutinaçäo microscópica. A análise dos resultados obtidos nesta avaliaçäo demonstra que o teste ELISA permite detectar níveis baixos de anticorpos circulantes, e também anticorpos näo aglutinantes, näo detectáveis através do teste de soroaglutinaçäo microscópica


Assuntos
Humanos , Ensaio de Imunoadsorção Enzimática , Leptospirose/diagnóstico , Imunoglobulina M/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA