Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Braz. dent. sci ; 24(1): 1-8, 2021. tab, ilus
Artigo em Inglês | BBO, LILACS | ID: biblio-1145549

RESUMO

Objective: The aim of this study was to compare the bond strength of High-Translucency zirconia (HT) and lithium disilicate dental ceramics, under different surface treatments. Material And Methods: For this, ceramics were divided into groups: Control Group (C) (n = 5), lithium disilicate sheets, conditioned with 10% hydrofluoric acid, followed by application of 37% phosphoric acid, silane and universal adhesive application; Group HTAI (n = 5), HT zirconia sheets were blasted with silica oxide, followed by the application of universal adhesive; Group HTPAI (n = 5), HT zirconia sheets were blasted with silica oxide, followed by the application of non-thermal plasma and universal adhesive and the HTP Group (n = 5), HT zirconia received only the application of non-thermal argon plasma. Subsequently, the specimens of each group were subjected to a cementation process with resin cement, obtaining cylinders. After 24 h of storage, in distilled water, at 37°C, the specimens were subjected to a mechanical micro-shear test. The data obtained were submitted to ANOVA One-way followed by the Tukey test (5%). Results: The HTP Group was excluded from the statistical analysis, as adhesions failed within the storage period. In addition, it was not possible to verify a statistical difference between the control group C and the experimental groups HTAI and HTPAI. Conclusion: The results showed that the applicability of high translucency zirconia can potentially be compared to the lithium disilicate bond strength, when submitted to the same surface treatments, except for the plasma application, which alone was not effective (AU)


Objetivo: O objetivo deste estudo foi comparar a resistência adesiva das cerâmicas dentárias de zircônia de alta translucidez e dissilicato de lítio. Materiais e Métodos: Para isso, cerâmicas foram divididas em grupos: Grupo Controle (C) (n = 5), lâminas de dissilicato de lítio, condicionadas com ácido fluorídrico 10%, seguido de aplicação do ácido fosfórico 37%, aplicação de silano e aplicação do adesivo universal; Grupo HTAI (n = 5), lâminas de zircônia HT foram submetidas ao jateamento com óxido de sílica, seguido da aplicação do adesivo universal; Grupo HTPAI (n = 5), lâminas de zircônia HT foram submetidas ao jateamento com óxido de sílica, seguido da aplicação do plasma não térmico e do adesivo universal e o Grupo HTP (n = 5), lâminas de zircônia HT receberam apenas a aplicação do plasma não térmico de argônio. Posteriormente, os espécimes de cada grupo foram submetidos a um processo de cimentação com cimento resinoso, obtendo-se cilindros. Após 24h, de armazenamento em água destilada a 37°C, os espécimes foram submetidos a ensaio mecânico de microcisalhamento. Os dados obtidos foram submetidos à ANOVA 1-fator seguido pelo teste de Tukey (5%). Resultados: O Grupo HTP foi descartado da análise estatística, pois as adesões falharam dentro do período de armazenamento. Além disso, não foi possível verificar diferença estatística entre o grupo controle C e os experimentais HTAI e HTPAI. Conclusão: Os resultados mostraram que a aplicabilidade das zircônias de alta translucidez pode potencialmente ser comparada à resistência adesiva da cerâmica de dissilicato de lítio, quando submetidas aos mesmos tratamentos de superfície, com exceção da aplicação de plasma, que isoladamente não foi efetiva (AU)


Assuntos
Ligas Metalo-Cerâmicas , Adesivos Dentinários , Cimentos de Resina , Cimentos Dentários
2.
Braz. dent. sci ; 22(4): 483-487, 2019. tab
Artigo em Inglês | BBO, LILACS | ID: biblio-1024436

RESUMO

Objective: This study aimed to evaluate and compare the retention force of individual clasps made from polyamide, acetate resin and cobalt-chrome for removable partial dentures. Material and methods: Three groups of clasps were fabricated: Cr-Co ­ 10 conventional chrome-cobalt metal clasps; Ac ­ 10 clasps with reciprocal arms and occlusal rests in chrome-cobalt and retentive arms in acetate resin; and Poly - 10 clasps with reciprocal arms and occlusal rests in chrome-cobalt and retentive arms in polyamide resin. Through the tensile test, in a universal testing machine, the initial retention force of the specimens was obtained and then clasps were cycled 7200 times, immersed in artificial saliva (60 months of simulated clinical use). After cycling, tensile test was performed. Results: All groups presented a retention decrease after the cycling. Ac presented a large reduction in retentive force (61.43%), followed by Cr-Co (26.5%) and Poly (12.09%). Conclusions: Aesthetic clasps of polyamide can be used in clinical cases where the anterior supporting teeth will not be essential for good retention of the removable partial denture because this clasp showed to be more resistant than the acetate resin. (AU)


Objetivo: Este estudo teve como objetivo avaliar e comparar a força de retenção de grampos individuais feitos de poliamida, resina de acetato e cromo-cobalto para próteses parciais removíveis. Material e Métodos: Três grupos de grampos foram fabricados: Cr-Co ­ 10 grampos metálicos convencionais de cromo-cobalto; Ac - 10 grampos com apoios e braço de oposição em cromocobalto e braços de retenção em resina de acetato; e Poly - 10 grampos com apoios e braço de oposição em cromo cobalto e braço de retenção em resina de poliamida. Por meio do teste de tração, em uma máquina de ensaio universal, a força de retenção inicial dos espécimes foi obtida e então, os grampos foram ciclados 7200 vezes, imersos em saliva artificial (60 meses de uso clínico simulado). Após a ciclagem, o teste de tração foi realizado. Resultados: Todos os grupos apresentaram diminuição da retenção após a ciclagem. Ac apresentou uma grande redução na força retentiva (61,43%), seguida por Cr-Co (26,5%) e Poly (12,09%). Conclusões: Grampos estéticos de poliamida podem ser usados em casos clínicos em que os dentes de suporte anteriores não serão essenciais para uma boa retenção da prótese parcial removível, pois esse grampo mostrouse mais resistente que os de resina de acetato (AU)


Assuntos
Grampos Dentários , Materiais Dentários , Prótese Parcial Removível
3.
Braz. dent. sci ; 22(4): 573-577, 2019. ilus
Artigo em Inglês | BBO, LILACS | ID: biblio-1024963

RESUMO

Accurate color selection of direct or indirect dental restorations is a subjective task. Mobile phones are tools that may minimize color assessment errors. The objective was to use photographs taken with smartphones to guide the dental surgeon in choosing the right color in oral rehabilitation. A tooth was photographed for color assessment and the VITA Toothguide 3D-MASTER® shade guide was used. Photographs were submitted to an image editing software for full saturation removal. Images of the tooth and scale in black and white were compared. This method allowed to select the tooth's value, which is considered the most subjective dimension in color choice. Although it is an auxiliary and complementary method to traditional methods, smartphones are tools capable of reducing the range of color possibilities and minimizing possible failures (AU)


A correta seleção da cor das restaurações dentais diretas ou indiretas é uma atividade subjetiva. Os celulares são ferramentas que podem minimizar os erros da tomada de cor. O objetivo foi utilizar fotografias realizadas com smartphones para orientar o cirurgião-dentista na escolha da cor em reabilitação oral. Foi fotografado um dente para tomada de cor e a escala Vita 3D Master. As imagens foram submetidas a um software de edição de imagem para remoção total da saturação. As imagens em preto e branco do dente e da escala foram comparadas. A metodologia permitiu selecionar o valor do dente que é o aspecto considerado mais subjetivo na escolha da cor. Apesar de ser um método auxiliar e complementar aos métodos tradicionais é uma ferramenta capaz de diminuir o leque de possibilidades de cores e minimizar possíveis falhas (AU)


Assuntos
Dente , Cor , Fotografia Dentária , Telefone Celular
4.
Braz. dent. sci ; 20(2): 146-151, 2017. ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-846451

RESUMO

Removable Partial Dentures (RPD) with dual path of insertion are designed to overcome conventional RPD esthetic limitations, through the use of proximal undercuts for rigid direct retainers. Therefore, dual path RPD is considered a variation of conventional RPD. This paper reports a clinical case where proper function as well as excellent esthetics were obtained with this type of RPD. (AU)


Próteses parciais removíveis (PPR) com dupla trajetória de inserção são próteses projetadas para superar limitações estéticas das próteses convencionais, utilizando-se retentores diretos rígidos nas áreas retentivas proximais dos dentes suportes. Desta forma, a PPR com dupla trajetória da inserção é considerada uma variação da PPR tradicional. O objetivo deste artigo é relatar um caso clínico onde se obteve uma resolução funcional e altamente estética através deste tipo de PPR..(AU)


Assuntos
Humanos , Prótese Parcial Removível
5.
Braz. dent. sci ; 20(3): 87-92, 2017. ilus, tab
Artigo em Inglês | LILACS, BBO | ID: biblio-868107

RESUMO

Objetivo: Este estudo teve como objetivo avaliar a retenção do grampo de resina de acetato quando comparado ao grampo metálico. Material e métodos: Para isso, 10 grampos metálicos Co-Cr convencionais (Ackers) e 20 de resina de acetate foram confeccionados. Os grampos de resina de acetato foram constituídos por braços de oposição, suporte e retenção feitos de CoCr. Dos 20 grampos estéticos, 10 tiveram a espessura do braço de retenção diminuídos para torná-los mais estéticos. A força de retenção inicial dos espécimes foi testada em uma máquina de teste universal através de teste de tração. Depois disso, os espécimes foram submetidos a 7.000 ciclos, cada um, em uma máquina adaptada, imersos em saliva artificial, por 36 meses, simulando uso clínico de uma prótese parcial removível. Os dados foram tabulados para análise estatística da eficácia de retenção. Resultados: Após ciclagem, os grampos de resina de acetato de 3 mm de espessura e 2 mm de espessura perderam mais retenção do que os grampos metálicos. O tipo de material (p = 0,0000) e a ciclagem (p = 0,0039) mostraram um efeito significativo, mas a interação material / ciclagem (p = 0,1436) não. Conclusões: Portanto, os grampos estéticos apresentaram força de retenção inferior à dos grampus metálicos. No entanto, os grampos estéticos podem ser utilizados em casos clínicos que requerem retenção mínima. (AU)


Objective: This study aimed to evaluate the retention of acetate resin clasp as when compared to metal clasp. Material and methods: For this purpose, we constructed 10 conventional Co-Cr metal clasps (Ackers) and 20 acetate resin clasps. The acetate resin clasps had the opposition, support and retaining arms made of Co-Cr. Of the 20 esthetic clasps, 10 had the thickness of the retention arm decreased to make it more esthetic. The initial retentive force of the specimens was tested in a universal testing machine through tensile test. After that, the specimens were subjected to 7,000 cycles, each one, in an adapted machine, immersed into artificial saliva, for 36 months of simulated clinical use of a removable partial denture. Data were tabulated for statistical analysis of the retention effectiveness. Results: After cycling, 3-mm-thick and 2-mmthick acetate resin clasps lost more retention than metal clasps. The material type (p=0.0000) and cycling (p=0.0039) showed a significant effect, but the material/cycling interaction (p=0.1436) did not. Conclusions: Therefore, esthetic clasps presented retention force lower than that of metal clasps. Notwithstanding, the esthetic clasps can be used in clinical cases requiring minimum retention. (AU)


Assuntos
Grampos Dentários , Prótese Parcial Removível
6.
Braz. dent. sci ; 17(2): 20-26, 2014. ilus, tab
Artigo em Inglês | LILACS, BBO | ID: lil-728133

RESUMO

Objective: The correct parallelism of guiding planes when constructing a Removable Partial Denture not only defines the axis of insertion and removal of the prosthesis, but also limits the possible axes of movement during functioning. Therefore, the purpose of the study was to compare some techniques and the use of an intra-oral device for those preparations. Material & Methods: Dummies were performed in a direct manner, simulating the absence of teeth 15, 45, 12 and 42. The four preparation techniques chosen were: Group 1 – freehand preparation; group 2 - guide pins; Group 3 - crown guides and Group 4 - parallel intraoral device – ParalAB. Results: No statistical difference was shown between the mean values of angles found for the freehand (82.85°) and guide pin (83.60°) groups. Also, no statistical significant difference was observed between the mean values of angles found for the resin cap (88.83) and intraoral device (88.58 º) groups; however they were superior to the findings for the freehand and guide pin groups. Conclusion: The studied methods are effective for what they were proposed; however, one should select the method according to the experience and skills, to promote the best results.


Objetivo: A transferência de planos de guia dos modelos de estudo para a boca é procedimento de extrema importância para o bom prognóstico de uma Prótese Parcial Removível. Objetivo: O objetivo do trabalho foi comparar diversas técnicas de confecção dos planos de guia, avaliando também a influencia da experiência do profissional executante. Material e Métodos: Manequins foram preparados simulando a ausência dos dentes 15, 45, 12 e 42. Foram realizadas 4 técnicas de preparo dos planos de guia, divididas em 4 Grupos: Grupo 1: técnica a mão livre; Grupo 2: técnica com pinos guias; Grupo 3: técnica com coroas guias; Grupo 4: Paralelômetro intra-oral – ParalAB. Estas técnicas foram executadas por profissionais com mais de 5 anos de formado e por alunos do ultimo ano de graduação em odontologia. Modelos de gesso foram obtidos antes e após a confecção dos preparos e comparados em uma máquina de leitura 3D. Resultados: Os resultados mostraram não haver diferença estatística entre os valores da angulação para o grupo 1 (82,85°) e grupo 2 (83,60°). Entre os grupos 3 (88,83°) e 4 (88,58°) também não houve diferença estatística, porém as técnicas dos Grupos 3 e 4 foram superiors às técnicas dos grupos 1 e 2. Em relação aos profissionais executantes, a experiência mostrou ter influência apenas nos grupos 1 e 2, não sendo significante nos grupos 3 e 4. Conclusão: Conclui-se que os métodos estudados foram efetivos para o propósito, e dependendo da sua experiência e habilidade, pode-se selecionar ao qual o profissional melhor se adpate, porém quando houver falta de experiência e confiança a técnica de coroas guias ou paralelômetro devem ser escolhidas.


Assuntos
Padrões de Prática Odontológica , Planejamento de Prótese Dentária , Prótese Parcial Removível
7.
Acta odontol. venez ; 50(1)2012. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-676737

RESUMO

Ya que este es un asunto muy discutido en la literatura, pero no completamente esclarecido El presente trabajo evaluó tridimensionalmente las alteraciones de impresiones con alginato tratadas con hipoclorito de sodio al 1%, a través de aerosol o inmersión. Se tomó la impresión de un padrón metálico simulando una arcada edéntula superior, con tres esferas fijadas en la región derecha, central e izquierda del reborde, y una cuarta esfera en el centro del paladar (puntos 1, 2, 3 y 4, respectivamente). Diez impresiones no fueron desinfectadas (G1=control). Diez impresiones fueron desinfectadas con aerosol de hipoclorito de sodio al 1% y enseguida fueron colocadas dentro de bolsas plásticas aguardándose 10 minutos (G2=aerosol), otras diez impresiones fueron inmersas en esta misma solución durante 10 minutos (G3=inmersión). Después, las impresiones de cada grupo fueron vaciadas con yeso tipo IV. Las mediciones fueron realizadas 24 horas después, en una máquina de coordenadas tridimensionales (Coordinate Mesuring Machine B504B, Mitutoyo), que calculó el centro de cada esfera y la distancia entre ellas. Los datos obtenidos fueron analizados por medio del análisis de varianza (ANOVA) y el test de Tukey (5%). No fueron encontradas diferencias estadísticamente significantes entre los tres grupos (G1,G2,G3) y el padrón metálico, sólo hubo diferencia entre G1 y G2, en dos de las seis distancias analizadas (1-2 y 1-3).


This study investigated the three dimensional changes of alginate impressions disinfected with 1% sodium hypoclorite by immersion and aerosol techniques, because there are controversies over it in literature. Impressions were taken from a metallic master model representing an edentulous maxillar arch with three spherical points (1, 2, 3) and the fourth one on the palate. Control samples (10 impressions) were poured directly using a special stone (control group). 10 impressions were disinfected by aerosol (aerosol group) and other 10 by immersion (immersion group), both techniques for 10 minutes. Next the stones were poured. After 24 hours the measurements were recorded by a Coordinate Measuring Machine, B504B, Mitutoyo. This machine determines the central of each sphere and the distances between them data was analyzed using ANOVA and Tukey tests (5%). The differences were significant between the control group and the aerosol group in two of six segments analyzed (1-2, 1-3). Significant differences were not found between any groups (immersion, aerosol e control) and the master model.


Assuntos
Humanos , Alginatos/análise , Desinfecção/métodos , Esterilização/métodos , Instrumentos Odontológicos/microbiologia , Produtos para Higiene Dental e Bucal
8.
Pesqui. bras. odontopediatria clín. integr ; 10(2): 177-181, maio-ago. 2010.
Artigo em Português | LILACS | ID: lil-568500

RESUMO

Objetivo: Avaliar e comparar diferentes resinas compostas na resistencia a fratura quando confeccionado nucleo de preenchimento. Metodo: Foram utilizados 36 dentes bovinos, os quais tiveram suas coroas seccionadas no terco cervical, padronizando o tamanho dos especimes em 20mm de comprimento. Os canais foram preparados com brocas do tipo largo no5 com irrigacao constante, correspondente ao tamanho e calibre dos pinos de fibra de vidro no3 Reforpost. Os pinos foram cimentados com cimento resinoso Enforce, sendo 16mm de pino dentro da raiz, e 4mm externo a raiz, depois polimerizados por 30 segundos de cada lado. Os corpos de provas foram divididos em tres grupos de 12, aos quais foram feitos munhoes de 4mm de diametro por 5mm de altura, confeccionados a parti r de um padrao prefabricado, sendo utilizado 3 tipos de resina: Grupo 1: Z100 (3M), Grupo 2: Z250(3M) e Grupo 3: P60(3M). Os corpos-de-prova foram fixados em um dispositivo cilindrico com um adaptador com inclinacao de 45§. Este dispositivo foi adaptado a uma maquina de Teste Universal (EMIC) para simular a forca ate a fratura do especime. Os dados foram submeti dos a Analise de Variancia (p<0,05). Resultados: Os munhoes confeccionados com resina Z250 apresentaram a maior media de valores de forca necessarias para fratura (45, 453 Kgf.), enquanto os grupos G1 e G3 obtiveram os seguintes valores de forca para fratura 38,014 kgf e 39,506 Kgf. respectivamente. Foi observado tambem que a resina P60 causou maior numero de fraturas radiculares. Conclusao: Pelas caracteristicas e propriedades das resinas testadas, a resina Z250 e mais indicada para a realizacao de nucleo de preenchimento.


Objective: To evaluate and compare the fracture strength of different composite resins used for core buildup. Method: Thirty-six bovine teeth were decoronated at the cervical third to standardize the length of specimens at 20 mm. Under constant irrigation, the canals were prepared with n§5 Largo drills corresponding to the size and diameter of n§3 Reforpost fiberglass post. The posts were cemented with Enforce resin sealer, being 16 mm inside the root canal and 4 mm outside the root canal, and the material was light-activated for 30 seconds at each side. The specimens were divided into 3 groups (n=12), in which cores (4 mm diameter and 5 mm high) were prepared from a prefabricated standard with three types of composite resins: Group 1: Z100 (3M), Group 2: Z250 (3M) and Group 3: P60 (3M). The specimens were fixed in a cylindrical device with an adaptor at 45§ inclination. This device was adapted to a universal testing machine (EMIC) to simulate the force until fracture of the specimen. Data were subjected to ANOVA (p<0.05). Results: The Z250 resin cores presented the highest mean fracture strength (45.453 kgf), while the mean fracture strengths in Group 1 and Group 3 were 38.014 and 39.506 kgf, respectively. P60 caused the largest number of root fractures. Conclusion: Considering the characteristics and properties of the tested resins, Z250 appears as the most indicated for core buildup.


Assuntos
Animais , Bovinos , Cimentos Dentários , Fraturas dos Dentes/etiologia , Resinas Compostas , Ciência dos Materiais , Análise de Variância
9.
RSBO (Impr.) ; 6(2): 147-154, jun. 2009. ilus, tab
Artigo em Português | LILACS-Express | LILACS | ID: lil-514882

RESUMO

Introdução: Recentemente a polimerização convencional de resina acrílica vem sendo trocada pela polimerização por micro-ondas. Objetivo: O estudo teve como objetivo avaliar a resistência flexural de diferentes resinas acrílicas, para confecção de próteses, quanto ao ciclo de polimerização convencional e por micro-ondas. Material e métodos: Foram confeccionados corpos-de-prova de 65 mm X 10 mm e 2,5 mm de espessura com diferentes resinas acrílicas, polimerizados pela técnica convencional e por micro-ondas. Os espécimes foram divididos em seis grupos, de acordo com a marca e o tipo de polimerização respectivamente: G1 (Clássico Convencional), G2 (Clássico Micro-ondas), G3 (Vip Dent Convencional), G4 (Vip Dent Micro-ondas), G5 (Palaton Convencional) e G6 (Palaton Micro-ondas). Os corpos-de-prova passaram por teste de tensão de flexão de três pontos até sua fratura. Resultados: Os testes Anova e Tukey para nível de significância 5% foram aplicados, e verificou-se diferença estatística entre o G1 (101,15±15,70) e os grupos G3 (85,51±10,79) e G5 (86,00±8,49); não houve diferença entre G3 e G5. Os grupos G2 (98,74±14,71), G4 (96,28±8,02) e G6 (92,81±11,38) não diferiram estatisticamente entre si e em relação aos outros grupos. Não houve diferença estatística entre as técnicas de polimerização. Conclusão: Para o ciclo de polimerização convencional, a resina da marca Clássico possui maior resistência se comparada com as outras duas marcas estudadas, e tanto o ciclo de polimerização convencional quanto o de micro-ondas podem ser bem indicados para o uso protético.


Introduction: Recently the conventional polymerization of acrylic resin has been changed by microwaves polymerization. Objective: The purpose of this study was to evaluate flexural strength of three different acrylic resins as for the cycle of conventional and microwaves polymerization. Material and methods: Specimens of 65 mm X 10 mm and 2.5 mm of dimension were made with different acrylic resins and polymerized trough the conventional and microwaves techniques. The specimens were divided in six groups in agreement with the mark and the polymerization type respectively: G1 (Clássico Conventional), G2 (Clássico Microwaves), G3 (Vip Dent Conventional), G4 (Vip Dent Microwaves), G5 (Palaton Conventional) and G6 (Palaton Microwaves). The specimens were tested by flexural strength until fracture. Results: The test Anova and Tukey for significance level of 5% was applied and there was statistic difference among G1 (101.15±15.70) and the groups G3 (85.51±10.79) and G5 (86.00±8.49), what did not occur among G3 e G5. There was not statistic difference among the groups G2 (98.74±14.71), G4 (96.28±8.02) and G6 (92.81±11.38) and in relation to the other groups. There was not statistic difference among the polymerization techniques. Conclusion: It was concluded that the Clássico resin for the cycle of conventional polymerization has higher strength compared to the other two studied marks, and both conventional polymerization and microwaves cycle can be indicated to prosthetic use.

10.
Odonto (Säo Bernardo do Campo) ; 16(32): 98-104, jul.-dez. 2008. ilus
Artigo em Português | LILACS, BBO | ID: lil-542934

RESUMO

Os conceitos de promoção de saúde, prevenção e a estética sedimentam a Odontologia atual, que atravessa um período de constante progresso. O surgimento das técnicas adesivas e materiais restauradores são um exemplo disso, devendo porém, sua aplicação clínica ser sustentada por bases científicas conseguidas por meio de pesquisas envolvendo novas técnicas e materiais. Devido a isso a resina composta foi o material mais intensamente pesquisado na última década com o intuito de melhorar suas propriedades negativas. Existem hoje no mercado diversos tipos de resinas, surgidas durante esse processo evolutivo, cada uma tendo suas indicações e limitações. As resinas mais atuais têm demonstrado, que não apenas a quantidade de carga vem sendo alvo de estudos como também seu formato, composição e distribuição, na tentativa de incrementar suas propriedades físicas e ópticas. Por isso, têm se dado bastante enfoque em diversas áreas sempre com o intuito de proporcionar aos pacientes melhores resultados estéticos, biológicos e funcionais. A nanotecnologia, que consiste na manipulação e medida de materiais na escala de abaixo de 100 nanômetros é um exemplo da exploração de novas áreas. Apesar de termos em mãos esse verdadeiro arsenal de materiais, nenhuma resina composta atingiu excelência de um material restaurador ideal. Prevêem-se para o início do milênio, melhoras consideráveis nas formulações das resinas compostas atuais e das novas que surgirão no sentido de melhorar as propriedades dos compósitos resinosos ampliando assim sua indicação.


In recent years the odontology suffered changes in some of its concepts, aesthetics and the search for conservatives treatments are part, nowadays, of the routine of the doctor’s offices and odontologic clinics. Because of this the composite resins was the material that has been more intensely searched in the last decade with intention to improve its negative properties. Types of resins, appeared during this evolutive process, each one having its indications and limitations. The most current resins have demonstrated, that not only the amount of load is theme for studies as well as its format, composition and distribution, in the attempt to develop its physical and optic properties. That is the reason why nowadays the nanotechnology, that consists of the manipulation and measure of materials in the scale below of 100 nanometers, is intensively being studied. These new materials present inorganic particles varying of 20-75nm, what diminishes the contraction of polymerization and it promotes satisfactory superficial smoothness. Although of having access to these new materials, no composite resin reached excellency of an ideal restoring material. They are foreseen for the beginning of the milenium, considerable improvements in the formularizations of current composite resins and the news that they will appear in the direction to improve the properties of the composite resins thus extending its indication.


Assuntos
Luz , Materiais Dentários , Resinas Compostas , Resinas Compostas/história , Resinas Compostas/química , Estética Dentária , Nanotecnologia
11.
Odonto (Säo Bernardo do Campo) ; 16(31): 77-84, jan.-jun. 2008.
Artigo em Português | LILACS, BBO | ID: lil-542829

RESUMO

O tratamento restaurador com a preservação de estrutura dental está fundamentado na utilização dos sistemas adesivos. Entretanto, a adesão à dentina tem sido um grande desafio para os pesquisadores, por ser um substrato heterogêneo. Atualmente, existe no mercado uma infinidade de marcas comerciais de sistemas adesivos com diferentes composições, métodos de aplicação e número de passos clínicos. Muitas vezes são lançados e retirados rapidamente do mercado, não havendo tempo para uma adequada avaliação clínica. Todos, de uma forma geral, têm como objetivo reduzir o número de passos operatórios e a sensibilidade da técnica adesiva e por sua vez, a microinfiltração. Diante desse questionamento, esta revisão teve como objetivo abordar o estágio atual em que se encontram os sistemas adesivos e quais as perspectivas futuras.


The establishment of adhesion of restorative materials has been replaced by tooth-conserving adhesive methods. However, dentin bonding is still a challenge, due to the great variation of dentin. Nowadays, there is an amount of adhesives systems, depending on how the steps are accomplished or simplified. There is a trend to move away from multicomponents bonding systems toward simplified; which reduces not only the clinical application time but also the sensitivity of the technique. In spite of this, the micromechanical bonding mechanism offered by the current adhesives must be analyzed under different aspects, in order to decrease a nanoleakage. Therefore, the aim of this review is approach the most recent concepts in adhesive systems and perspectives for the future.


Assuntos
Adesivos Dentinários/química , Infiltração Dentária , Dentina , Dentina , Materiais Dentários/química , Adesividade
12.
RGO (Porto Alegre) ; 55(3): 297-300, jul.-set. 2007. ilus
Artigo em Português | LILACS, BBO | ID: lil-519072

RESUMO

Um dos grandes problemas encontrados na utilização de uma prótese parcial removível pelo paciente é a difícil adaptação ao conector maior e a exigência da estética pela presença de grampos. O caso clínico relata passo-a-passo uma reabilitação de um paciente parcialmente desdentado por uma prótese parcial removível unilateral utilizando sistema de coroas telescópicas.


Assuntos
Humanos , Masculino , Coroas , Prótese Parcial Removível , Estética Dentária
13.
RGO (Porto Alegre) ; 54(4): 328-333, out.-dez. 2006. ilus, tab
Artigo em Português | LILACS, BBO | ID: lil-461702

RESUMO

A proposta deste estudo foi avaliar a influência de três técnicas de transferência de planos guia para boca, a influência da experiência do operador, da região (anterior e posterior), da arcada (inferior e superior) e a interação destas quanto ao preparo de planos de guia confeccionados nas faces proximais de dentes suportes para prótese parcial removível. Foram instruídos 10 operadores (cirurgiões dentistas), 5 com mais de 5 anos de experiência e 5 alunos do último ano de graduação da Faculdade de Odontologia de São José dos Campos, Universidade Estadual Paulista "Julio de Mesquita Filho". Cada operador utilizou três técnicas que foram: método à mão livre, método com pino guia e método com delineador intrabucal (ParalAB), em manequins simulando classe três de Kennedy. A análise estatística ANOVA e o teste de Tukey foram os métodos utilizados para a interpretação dos resultados. Concluiu-se que a técnica que empregou o delineador intrabucal ParalAB obteve melhor paralelismo, seguido pela técnica com Pino Guia e pela técnica à Mão Livre. De acordo com a metodologia aplicada, foi possível concluir que a técnica empregada na realização dos preparos de planos de guia para a boca influencia na inclinação das superfícies produzidas, e que a experiência do operador interfere no grau de paralelismo executado por qualquer técnica, exceto os resultados obtidos pela técnica com ParalAB que usou um delineador intrabucal. A arcada superior e a região anterior tiveram melhores resultados em ambos os operadores.


Assuntos
Dente Suporte , Arco Dental , Prótese Parcial Removível
14.
Rev. odontol. Univ. Cid. Sao Paulo ; 18(2): 161-166, maio-ago. 2006. tab, graf
Artigo em Português | LILACS, BBO | ID: lil-550082

RESUMO

Introdução: O presente trabalho tem como objetivo estudar o efeito da saliva artificial na resistência flexural de resina acrílica para bases de próteses. Métodos: Foram confeccionados 80 corpos-de-prova padronizados conforme a Especificação nº 12 da American Dental Association (65 x 10 x 2,5 mm). O acabamento foi feito em torno mecânico e o polimento com lixas seguindo a seqüência: 240, 380, 480 e 600. Os corpos-de-prova foram divididos em 2 grupos distintos: Grupo 1: controle (n=40), armazenado em água destilada e Grupo 2: experimental (n=40), em saliva artificial, ambos a 37°C até o ensaio mecânico. Os testes foram realizados nos intervalos de tempo, 1, 7, 15 e 30 dias. Os corpos-de-prova foram submetidos ao teste de ensaio de flexão de três pontos. Os corpos-de-prova foram tencionados continuamente até ocorrer a fratura. Os ensaios de tensão foram realizados em uma máquina Universal de Ensaio (EMICDL1000). Os dados obtidos foram analisados estatisticamente pelo teste de ANOVA (p<0,05) e Tukey (5%). Resultados e conclusão: Os resultados mostraram que não houve diferença estatística significante entre o grupo controle e o grupo imerso em saliva artificial, não havendo diferença também para o tempo de estocagem de um, sete, quinze e trinta dias.


Introduction: The aim of this study is to study of the effect of artificial saliva on flexural strenght of acrylic resin denture bases. Methods: 80 samples were standardized confectioned as Specification nº 12 of the Dental American Association (65 x 10 x 2,5 mm). The finishing was made in lathe and burnishing with sandpapers following the sequence: 240, 380, 480 and 600. The samples were divided in 2 groups: Group 1, control, stored in distilled water and Group 2, experimental, in artificial saliva, both at 37°C. The tests were realized in the intervals 1, 7, 15 and 30 days. The samples were submitted to three points flexure test. The samples were intended continuously until occurring the fracture. The tension tests were realized in a universal testing machine (EMIC-DL1000). The obtained data were analyzed statistically by ANOVA test and Tukey. Results and conclusion: The results showed that both groups in both tests have no significant statistic difference.


Assuntos
Prótese Dentária , Resinas Acrílicas , Saliva Artificial
15.
Braz. dent. j ; 17(4): 290-295, 2006. tab, ilus
Artigo em Inglês | LILACS | ID: lil-442396

RESUMO

The purpose of this in vitro study was to evaluate the effect of different surface treatments on the shear bond strength of a resin-based cement to porcelain. Sixty pairs of 50 percent aluminous porcelain discs were fabricated. In each pair, one disc measured 6 mm in diameter X 3 mm thickness (A) and the other measured 3 mm in diameter X 3mm thickness (B). The specimens were randomly assigned to 6 groups (n=10 pairs of discs), according to the surface treatment: etching with 10 percent hydrofluoric acid for 2 or 4min (G1 and G2); 50-æm particle aluminum oxide sandblasting for 5 s (G3); sandblasting followed by etching for 2 or 4min (G4 and G5) and control - no treatment (G6). A silane agent was applied to the treated surface of both discs of each pair. Bistite II DC dual-cure resin cement was applied and the B discs were bonded to their respective A discs. Specimens were stored in distilled water at 37°C for 24 h and were tested in shear strength at a crosshead speed of 2 mm/min. Means in MPa were: G1: 14.21 ± 4.68; G2: 8.92 ± 3.02; G3: 10.04 ± 2.37; G4: 12.74 ± 5.15; G5: 10.99 ± 3.35; G6: 6.09 ± 1.84. Data were compared by one-way ANOVA and Tukey's test at 5 percent significance level. Bond strength recorded after 2-min acid etching was significantly higher than 4-min etching (p<0.05) and control (p<0.05), but did not differ significantlyfrom sandblasting alone (p>0.05) or followed by etching for 2 or 4 min (p>0.05). Within the limitations of an in vitro study, it may be concluded that 2-min hydrofluoric acid etching produced a favorable micromechanical retention that enhanced resin cement bond strength to porcelain.


O objetivo deste estudo in vitro foi avaliar o efeito de diferentes tratamentos de superfície na resistência ao cisalhamento da união entre porcelana e cimento resinoso. Foram confeccionados sessenta pares de discos de porcelana aluminizada a 50 por cento, de 6 mm de diâmetro por 3 mm de espessura (A) e 3 mm de diâmetro por 3 mm de espessura (B). Os espécimes foram divididos aleatoriamente em 6 grupos (n=10 pares), de acordo com os tratamentos de superfície: condicionamento com ácido fluorídrico por 2 e 4 min (G1 e G2), jateamento com óxido de alumínio (50 æm) por 5 s (G3), jateamento seguido de ácido fluorídrico por 2 e 4 min (G4 e G5) e controle (G6). Em seguida, foi aplicado silano na superfície tratada de ambos os discos, e os discos B foram cimentados sobre os respectivos discos A, utilizando o cimento resinoso dual Bistite II DC. Os espécimes foram armazenados em água destilada a 37°C por 24 h, para posterior teste de cisalhamento em máquina de ensaio universal. As médias em MPa foram: G1: 14,21 ± 4,68; G2: 8,92 ± 3,02; G3: 10,04 ± 2.37; G4: 12,74 ± 5,15; G5: 10,99 ± 3,35; G6: 6,09 ± 1,84. Os dados foram submetidos à análise de variância a um critério e teste de Tukey (p<0,05). O condicionamento ácido por 2 min apresentou resultados significantemente superiores ao condicionamento por 4 min (p<0,05) e ao grupo controle (p<0,05), porém não diferiu estatisticamente do jateamento, associado ou não ao ácido fluorídrico por 2 ou 4 min (p>0,05). Dentro das limitações de um estudo in vitro, conclui-se que o condicionamento com ácido fluorídrico por 2 min produziu uma retenção micromecânica favorável, que aumentou a resistência de união entre o cimento resinoso e a porcelana.


Assuntos
Humanos , Colagem Dentária , Porcelana Dentária/química , Cimentos de Resina/química , Condicionamento Ácido do Dente , Adesividade , Abrasão Dental por Ar , Óxido de Alumínio/química , Resinas Compostas/química , Análise do Estresse Dentário/instrumentação , Ácido Fluorídrico/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Resistência ao Cisalhamento , Propriedades de Superfície , Silanos/química , Temperatura , Fatores de Tempo , Água/química
16.
Ciênc. odontol. bras ; 8(3): 22-28, jul.-set. 2005. ilus
Artigo em Português | LILACS, BBO | ID: lil-450412

RESUMO

O objetivo deste trabalho in vivo foi avaliar a adaptação de apoios em cíngulo confeccionados sobre esmalte ou resina composta em Próteses Parciais Removíveis. Após a prova e ajuste da armação metálica e anteriormente ao registro da relação maxilo-mandibular foram selecionados caninos com apoios considerados adaptados clinicamente, totalizando uma amostra de 16 apoios em esmalte (Grupo A) e 16 apoios em resina composta (Grupo B). A adaptação foi verificada utilizando uma silicona por condensação leve (Heraeus Kulzer). O material foi manipulado e colocado na face interna do apoio, em seguida a armação metálica foi inserida na boca de acordo com a trajetória de inserção até a posição de assentamento final. Após a polimerização, o material adere a armação metálica que foi removida da boca. Outra silicona por condensação média (3M) foi colocada sobre o material anterior, formando o corpo-de-prova, que foi seccionado longitudinalmente na região mais profunda do preparo. Sua espessura mostrou o grau de adaptação entre a fundição e o dente suporte. As medidas foram feitas utilizando projetor de perfil (MP320- Carl Zeiss, JENA). Os resultados foram analisados através do Teste de Mann-Whitney (5%), onde foi observada uma diferença significante (p=0,017) entre os dois grupos(Grupo A= 0,584 ± 0,325mm e Grupo B= 0,311 ± 0,237mm). Os apoios confeccionados sobre resina composta apresentaram uma melhor adaptação ao preparo para apoio do que os realizados sobre esmalte.


Assuntos
Humanos , Resinas Compostas , Dente Suporte , Esmalte Dentário , Materiais Dentários , Prótese Parcial Removível , Estatísticas não Paramétricas
17.
RPG rev. pos-grad ; 9(2): 116-122, abr.-jun. 2002. ilus, tab, graf
Artigo em Português | LILACS, BBO | ID: lil-336386

RESUMO

Os apoios säo elementos importantes na execuçäo da prótese parcial removível, evitando seu deslocamento no sentido ocluso-gengival e transmitindo as forças mastigatórias aos dentes suportes. O recontornamento de cíngulo com resina composta tem sido adotado como uma soluçäo para a confecçäo de preparos para apoio em dentes anteriores com reduzida espessura de esmalte. Para refinar essa técnica, este trabalho visa comparar o desempenho de um polímero de vidro (Artglass - Heraeus/Kulzer) em relaçäo à resina composta (Z100-3M). Para isto, foram utilizados 40 incisivos bovinos aleatoriamente divididos em dois grupos com 20 amostras cada: Grupo A (Z100-3M) e Grupo B (Artglass - Heraeus/Kulzer). As áreas de adesäo foram planificadas, limpas e condicionadas com ácido fosfórico a 37 por cento por 30 s. O Grupo A recebeu cilindros de resina composta Z100 construídos pela técnica incremental, e o Grupo B, cilindros de Artglass cimentados com cimento resinoso (3M). Os corpos-de-prova foram termociclados (300 ciclos) e mantidos em água destilada a 37ºC por 24 horas antes de serem submetidos ao teste de cisalhamento em máquina de ensaio Instron, à velocidade de 0,5 mm/min. Os dados obtidos foram analisados pelo teste de Mann-Whitney (p < 0,0001). Os resultados indicaram uma diferença significativa ao nível de 5 por cento, entre o Grupo A (15,79 MPa) e o Grupo B (11,82 MPa). As forças de adesäo do Artglass ultrapassaram em 2 vezes a carga mastigatória máxima estabelecida para pacientes edentados parciais, além de todos os corpos-de-prova terem permanecido íntegros. Portanto esse material poderia ser considerado uma boa alternativa para recontornamento de cíngulo


Assuntos
Animais , Bovinos , Resinas Compostas , Polímeros , Dente Suporte , Prótese Parcial Removível , Resistência à Tração
18.
JBC j. bras. clin. odontol. integr ; 6(31): 19-23, jan.-fev. 2002. ilus
Artigo em Português | LILACS, BBO | ID: lil-336411

RESUMO

Overdenture ou sobredentaduras säo próteses removíveis totais ou parciais que recobrem um ou mais dentes suportes ou implantes. A preservaçäo de dentes naturais ou raízes suportes para overdentures pode ser considerada uma opçäo alternativa válida para próteses totais e parciais removíveis. Estes suportes possibilitam um retardo na reabsorçäo do osso alveolar, mantêm a propriocepçäo periodontal e a eficiência mastigatória. No entanto, parece que os dentes suportes de overdentures säo muito suscetíveis às cáries e à doença periodontal. Nesta revisäo da literatura, avaliamos a importância da manutençäo da higiene oral pelo paciente, retornos para controle e uso de flúor tópico no sucesso do tratamento com overdentures


Assuntos
Prótese Total , Prótese Parcial Removível , Dente Suporte , Cárie Dentária , Higiene Bucal , Doenças Periodontais
19.
Rev. Assoc. Paul. Cir. Dent ; 53(1): 21-4, jan.-fev. 1999. ilus
Artigo em Português | LILACS, BBO | ID: lil-246592

RESUMO

O presente trabalho tem como objetivo conscientizar a classe odontológica dos riscos de infecçäo cruzada provenientes da manipulaçäo de moldes e modelos de gesso por parte do CD e de toda a sua equipe (principalmente os técnicos de laboratório de prótese), bem como divulgar métodos de desinfecçäo simples, seguros, rápidos e fáceis, com base numa revisäo literária de 20 anos. Os materiais de moldagem mais usados atualmente possuem tratatamento adequado para sua desinfecçäo, procedimento que näo inviabiliza os moldes para as finalidades que säo indicadas. Apesar de pouco divulgados no nosso país, esses métodos, uma vez que säo conhecidos pelo profissional, devem ser obrigatoriamente adotados na prática diária, já que, além da preservaçäo de sua própria saúde, é de responsabilidade do CD preservar também a saúde de seus pacientes e de sua equipe


Assuntos
Desinfecção/métodos , Modelos Anatômicos , Moldes Genéticos
20.
São José dos Campos; s.n; 1999. 136 p. ilus, tab. (BR).
Tese em Português | LILACS, BBO | ID: lil-399582

RESUMO

O estudo foi realizado com oitenta incisivos inferiores bovinos. Os dentes foram extraídos, limpos, as raízes foram seccionadas, o tecido pulpar coronário foi removido e submetido à congelamento a - 18 graus C, por um tempo máximo de 28 dias. A inclusão foi feita em gesso pedra tipo IV. Após o desgaste do esmalte, a dentina superficial foi preparada numa área de 5mm, sendo que a espessura de dentina remanescente foi padronizada (1,7 a 2mm). Os discos de liga de Ni-Cr tinham 3X5mm de diâmetro e todos foram submetidos a um ciclo de queima de cerâmica. Metade dos discos foram jateados com óxido de alumínio de 50 m, enquanto a outra metade não sofreu este tratamento. Após limpeza em ultra-som os discos foram cimentados à dentina com: cimento de fosfato de zinco-S.S.White (controle), cimento de ionômero de vidro modificado por resina (CIVMR) Fuji Plus-Fuji, Cimento Resinoso 3M-3M e cimento resinoso Panavia 21-Kuraray. Os dados, após análise estatística ANOVA e teste de Tukey (p<0,05), mostraram para as variáveis cimento e tratamento de superfície dos discos metálicos os seguintes valores médios de resistência da união dentina/cimento/metal: cimento resinoso Panavia 21 com jateamento (18,29MPa), sem jateamento (17,87MPa); Cimento Resinoso 3M com jateamento (15,81MPa), sem jateamento (11,40MPa); CIVMR com jateamento (16,57MPa), sem jateamento (16,70MPa); cimento de fosfato de zinco com jateamento (3,35MPa), sem jateamento (0,98MPa). As médias dos valores de resistências ao cisalhamento permitiram concluir: a) houve diferença estatisticamente significante entre o cimento controle e os cimentos em teste; b) não houve diferença estatisticamente significante entre o cimento resinoso Panavia 21 e o CIVMR, mas ambos foram estatisticamente diferentes do cimento resinoso 3M; c) houve diferença estatisticamente significante entre as médias de resistência dos espécimes jateados (13,51MPa) e os não jateados com óxido de alumínio (11,74MPa); d) não foram observadas diferenças estatisticamente significantes entre os cimentos CIVMR e Panavia 21, com e sem jateamento


Assuntos
Cimentos Dentários , Dentina , Adesivos Dentinários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA