Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Rev. bras. geriatr. gerontol. (Online) ; 27: e230189, 2024. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1550770

RESUMO

Resumo Objetivos Identificar os instrumentos de avaliação de equilíbrio, quedas e risco de quedas utilizados na DPOC, avaliar suas propriedades de medida, qualidade da evidência e utilidade clínica. Método A revisão foi produzida seguindo as orientações PRISMA e COSMIN, registrada no PROSPERO: CRD42021235118. As pesquisas foram realizadas de novembro de 2021 a setembro de 2022 nas bases de dados PubMed, LILACS, CINAHL, Embase, Web of Science e PEDro. Estudos observacionais transversais e coorte foram incluídos, sem restrição de idioma ou ano de publicação, desde que descreveram instrumentos clínicos de avaliação do equilíbrio, quedas e risco de quedas reportando no mínimo, uma das propriedades de medida: validade, confiabilidade e responsividade. Dois revisores independentemente aplicaram os critérios de elegibilidade, risco de viés pela COSMIN, qualidade da evidência pela abordagem GRADE e a avaliação da utilidade clínica pela Escala de Tyson e Connell. Resultados 9.102 estudos foram selecionados e 21 incluídos na revisão, nove estudos demonstraram propriedades de medida adequadas e suficientes e 12 instrumentos foram identificados, dos quais seis, foram avaliados quanto a qualidade de evidência. Conclusão Revisões sistemáticas de propriedades de medida requerem revisores especializados e habilidade em análise qualitativa. Com grau de recomendação "A", a Berg Balance Scale (BBS) e o teste Timed Up and Go (TUG) foram os instrumentos mais indicados na DPOC. Ao acrescentar a avaliação da utilidade clínica ao resultado, o TUG demonstra superioridade ao BBS, demostrando ser uma ótima ferramenta para triar indivíduos que necessitem de uma avaliação minuciosa do equilíbrio, quedas e risco de quedas.


Abstract Objectives to identify balance assessment instruments, issues and risks of issues used in COPD, evaluate their measurement properties, quality of evidence and clinical utility. Method A review was produced following the PRISMA and COSMIN guidelines, registered in PROSPERO: CRD42021235118. Searches were carried out from November 2021 to September 2022 in the PubMed, LILACS, CINAHL, Embase, Web of Science and PEDro databases. Cross-sectional and cohort observational studies were included, without restrictions on language or year of publication, as long as they described clinical instruments for assessing balance, falls and risk of falls reporting at least one of the measurement properties: validity, reliability and responsiveness. Two reviewers will independently apply the eligibility criteria, travel risk by COSMIN, quality of evidence by the GRADE approach and assessment of clinical utility by the Tyson and Connell Scale. Results 9,102 studies were selected and 21 included in the review, nine studies demonstrated adequate and sufficient measurement properties and 12 instruments were identified, of which six were evaluated for the quality of evidence. Conclusion Systematic reviews of measurement properties require specialized reviewers and skills in qualitative analysis. With a recommendation GRADE of "A", the Berg Balance Scale (BBS) and the Timed Up and Go (TUG) test were the most recommended instruments for COPD. By requiring the evaluation of the clinical utility of the result, the TUG demonstrates superiority to the BBS, proving to be a great tool for judging individuals who need a thorough assessment of balance, falls and risk of falls.

2.
Adv Rheumatol ; 64: 5, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1533539

RESUMO

Abstract Background Knowledge of patients about Rheumatoid Arthritis (RA) is a necessary aspect to better approach self-management support in a patient-centered manner. The research instrument known as the Rheumatoid Arthritis Knowledge Assessment Scale (RAKAS), consisting of 13 items, is simple, reliable and reproducible, and can be applied in both clinical practice and research protocols. Objectives This study aimed to translate and culturally adapt the RAKAS vocabulary into Brazilian Portuguese and to evaluate its concurrent validity. Methods The RAKAS was translated into Brazilian Portuguese and administered to 52 elderly women with RA recruited between May 2021 and May 2022. Concurrent validity was assessed using the Spearman's correlation coefficient between RAKAS and Patient Knowledge Questionnaire (PKQ). Results The participants considered RAKAS-13/BRAZIL easy to understand and did not report any doubts in answering the final version. Concurrent validity of the RAKAS-13/BRAZIL was low compared to the PKQ (ρ = 0.283, p = 0.038). Conclusion The Brazilian Portuguese version of the RAKAS (RAKAS-13/BRASIL) proved to be a questionnaire that was easy and quick to administer to assess patient knowledge about Rheumatoid Arthritis, despite its low correlation with the PKQ in the present study.

3.
Fisioter. Mov. (Online) ; 37: e37107, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1534459

RESUMO

Abstract Introduction The study of the diaphragm muscle has aroused the interest of physiotherapists who work with kinesiological ultrasonography, but still little explored; however, its findings can contribute to the clinical practice of hospitalized patients in neonatal intensive care units. Objective To measure the excursion and thickening of the diaphragm and describe measurements among neonates, preterm, and full-term. Methods Diaphragmatic kinesiological ultrasonography was performed on hospitalized newborns, in Neonatal Unit Care Unit, placed in supine position in their own bed, on the sixth day of life. Three repeated measurements of the same respiratory cycle were made, both for excursion and for diaphragmatic thickening. Results 37 newborns participated in the study and 25 were premature. The mean weight at the time of collection was 2,307.0 ± 672.76 grams and the gestational age was 35.7 ± 3.3 weeks. Diaphragmatic excursion increased with increasing gestational age (p = 0.01, df = 0.21) in term infants (p = 0.17, df = 0.35). Conclusion There was a positive correlation between diaphragmatic excursion and gestational age. There was no statistically significant difference in the measurements of excursion and inspiratory diaphragm thickening between preterm and term newborns, although pointing to higher measurements in the latter group.


Resumo Introdução O estudo do músculo diafragma tem des-pertado o interesse dos fisioterapeutas que trabalham com ultrassonografia cinesiológica. Ainda pouco explo-rado, contudo, seus achados podem contribuir para a prática clínica dos pacientes internados em unidades de terapia intensiva neonatal (UTIN). Objetivo Mensurar a excursão e o espessamento diafragmático e descrever as medidas entre recém-nascidos prematuros e a termo. Métodos Realizou-se ultrassonografia cinesiológica diafragmática em recém-nascidos internados em UTIN, posicionados em supino em seu próprio leito, no sexto dia de vida. Foram realizadas três medidas repetidas do mesmo ciclo respiratório, tanto da excursão quanto do espessamento diafragmático. Resultados Participaram do estudo 37 recém-nascidos, dos quais 25 eram pre-maturos. O peso no momento da coleta foi de 2.307,0 ± 672,76 gramas e a idade gestacional foi de 35,7 ± 3,3 semanas. A excursão diafragmática aumentou de acordo com o aumento da idade gestacional (p = 0,01; df = 0,21). A espessura variou entre 0,10 e 0,16 cm durante a inspiração nos prematuros e entre 0,11 e 0,19 cm nos nascidos a termo (p = 0,17; df = 0,35). Conclusão Houve correlação positiva entre a excursão diafragmá-tica e a idade gestacional. Não observou-se diferença estatisticamente significativa das medidas de excursão e de espessamento diafragmático inspiratório entre recém-nascidos prematuros e recém-nascidos a termo, embora apontando para maiores medidas neste último grupo.

4.
Fisioter. Mov. (Online) ; 36: e36117, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1448254

RESUMO

Abstract Introduction The intervention of respiratory physio-therapy in neonatal units is in continuous development, having its own care characteristics related to the weight and gestational age of the newborn, respecting the immaturity of the organs and systems and the diseases of this patient. Through techniques, the objective is to optimize the respiratory function, assisting in the clearance of secretions, and the restoration of lung volumes. Objective To verify if the respiratory physiotherapy technique of selective insufflation alters the cerebral blood flow in premature infants under 34 weeks of gestational age. Methods This is an uncontrolled clinical trial, conducted in a Neonatal Intensive Care Unit of a level III hospital, between January 2019 and March 2020, with participation of premature newborns under 34 weeks of gestational age. All were submitted to transfontanellar Doppler ultrasonography to assess cerebral blood flow measurements, mainly the resistance index, before and after the application of the selective insufflation respiratory physiotherapy technique. Results Sixty-two newborns were included, with a mean gestational age of 29.3 ± 2.2 weeks and birth weight of 1,259 ± 388 grams. The resistance index did not change significantly (RI before: 0.55 ± 0.07; after: 0.54 ± 0.07; p = 0.06) before and after the intervention and no studied variables such as, gender, gestational age, weight, Apgar score or SNAPPE II score had an influence on cerebral blood flow measurements. Conclusion The selective insufflation technique did not alter cerebral blood flow in premature newborn infants under 34 weeks gestational age.


Resumo Introdução A intervenção da fisioterapia respiratória nas unidades neonatais está em contínuo desenvolvimento, tendo características próprias de atendimento relacio-nadas ao peso e à idade gestacional do recém-nascido, respeitando a imaturidade dos órgãos e sistemas e as doenças desse paciente. Objetivo Verificar se a técnica de fisioterapia respiratória de insuflação seletiva altera o fluxo sanguíneo cerebral de prematuros menores de 34 semanas de idade gestacional. Métodos Trata-se de um ensaio clínico não controlado, realizado em uma Unidade de Terapia Intensiva Neonatal de um hospital nível III, entre janeiro de 2019 e março de 2020, com a participação de recém-nascidos prematuros menores de 34 semanas de idade gestacional. Todos foram submetidos ao exame de ultrassonografia transfontanela com Doppler para avaliar as medidas de fluxo sanguíneo cerebral, principalmente o índice de resistência, antes e depois da aplicação da técnica de fisioterapia respiratória de insuflação seletiva. Resultados Sessenta e dois recém-nascidos foram incluídos, com média de idade gestacional de 29,3 ± 2,2 semanas e peso de nascimento de 1259 ± 388 gramas. O índice de resistência não se modificou de forma significativa antes e depois da intervenção (IR antes: 0,55 ± 0,07; depois: 0,54 ± 0,07; p = 0,06) e nenhuma variável estudada, como sexo, idade gestacional, peso, escore de Apgar ou escore SNAPPE II, teve influência nas medidas de fluxo sanguíneo cerebral. Conclusão A técnica de insuflação seletiva não alterou o fluxo sanguíneo cerebral de recém-nascidos prematuros menores de 34 semanas de idade gestacional.

5.
Fisioter. Mov. (Online) ; 36: e36102, 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1421466

RESUMO

Abstract Introduction Multiple studies have shown the effects of prone (PP), supine (SP) and kangaroo (KP) positions on clinical and physiological outcomes in preterm newborns, but none compared these three types of positioning between them. Objective To investigate the influence of these positionings on heart rate, respiratory rate, peripheral oxygen saturation (SpO2) and alertness status in clinically stable preterm newborns (NBs) admitted to a neonatal intensive care unit. Methods In a randomized clinical trial, clinically stable NBs with gestational ages from 30 to 37 weeks who were breathing spontaneously were allocated in three positioning groups: PP, SP and KP. Heart rate, breathing frequency, SpO2 and alertness status were evaluated immediately before and after 30 minutes of positioning. Results In all, 66 NBs were assessed (corrected age: 35.48 ± 1.94 weeks; weight: 1840.14 ± 361.09 g), (PP: n = 22; SP: n = 23; KP: n = 21). NBs in the PP group showed a significant improvement in peripheral SpO2 (97.18 ± 2.16 vs 95.47 ± 2.93 vs 95.57 ± 2.95, p = 0.03) compared with the SP and KP groups. Conclusion In clinically stable preterm NBs, the PP was associated with better peripheral oxygen saturation than the SP or KP. In addition, there was a reduction in heart rate within prone position group and in the KP group there was an increase in the number of NBs in the deep sleep classification.


Resumo Introdução Vários estudos têm demonstrado os efeitos das posições prona (PP), supina (SP) e canguru (KP) sobre os resul-tados clínicos e fisiológicos em recém-nascidos prematuros, mas nenhum comparou esses três tipos de posicionamento. Objetivo Investigar a influência desses posicionamentos na frequência cardíaca, frequência respiratória, saturação periférica de oxigênio (SpO2) e estado de alerta em recém-nascidos pré-termo (RN) clinicamente estáveis internados em uma unidade de terapia intensiva neonatal. Métodos Em um ensaio clínico randomizado, RN clinicamente estáveis com idade gestacional de 30 a 37 semanas e respirando espontaneamente foram alocados em três grupos de posicionamento: PP, SP e KP. Frequência cardíaca e respiratória, SpO2 e estado de alerta foram avaliados imediatamente antes e após 30 minutos de posicionamento. Resultados Ao todo, foram avaliados 66 RNs (idade corrigida: 35,48 ± 1,94 semanas; peso: 1840,14 ± 361,09 g), (PP: n = 22; SP: n = 23; KP: n = 21). Os RNs do grupo PP apresentaram melhora significativa na SpO2 periférica (97,18 ± 2,16 vs 95,47 ± 2,93 vs 95,57 ± 2,95, p = 0,03) em comparação aos grupos SP e KP. Conclusão Em RN prematuros clinicamente estáveis, o PP foi associado à melhor saturação periférica de oxigênio do que o SP ou KP. Além disso, houve redução da frequência cardíaca no grupo de posição prona e no grupo KP houve aumento do número de RNs na classificação sono profundo.


Assuntos
Humanos , Recém-Nascido , Recém-Nascido Prematuro , Modalidades de Fisioterapia , Posicionamento do Paciente , Unidades de Cuidados Respiratórios , Terapia Respiratória , Unidades de Terapia Intensiva Neonatal , Frequência Cardíaca
6.
Fisioter. Mov. (Online) ; 36: e36132, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1520909

RESUMO

Abstract Introduction The manual rib cage stabilization maneu-ver (MRCSM) is a physical therapy intervention that promotes stabilization of the zone of apposition of the diaphragm, facilitating the contraction of this muscle and the work of breathing. Objective To evaluate by diaphragm ultrasound the diaphragmatic excursion in premature newborns before and after MRCSM. Methods Before-after clinical trial assessing by diaphragm ultra-sound the effectiveness of MRCSM in the amplitude of diaphragmatic excursions. Results The study sample consisted of 48 premature newborns born at a mean gestational age of 33.0 ± 2.8 weeks with a mean birth weight of 1,904.1 ± 708.9 grams. The newborns were classified in three groups: without respiratory distress syndrome (RDS; n = 26), with RDS (n = 15) and with apnea (n = 7) as a cause of admission to the neonatal intensive care unit (NICU). The measurements of diaphragmatic excursion and thickening were similar in newborns without or with RDS or apnea and there was a significant increase in the amplitude of diaphragmatic excursions after MRCSM (p < 0.001; effect size > 0.68) and less diaphragmatic thickening at exhalation in all of them. The diaphragm thickening fraction was 0.50 (0.33 - 0.72), and the diaphragm thickening rate was 0.04 (0.03 - 0.07). These measurements showed no significant variation with the presence or absence of RDS or apnea (p > 0.05). No significant variations in heart rate (p = 0.30), respiratory rate (p = 0.79), and peripheral oxygen saturation, consid-ering newborns in ambient air (p = 0.17) compared with baseline. Conclusion The MRCSM was effective, safe, and increased the amplitude of diaphragmatic excursion and thickness in premature newborns at one week of age, regardless of the presence or absence of RDS or apnea as a cause of admission to the NICU.


Resumo Introducão A manobra manual de estabilização da caixa torácica (MRCSM) é uma intervenção fisioterapêutica que promove a estabilização da zona de aposição do diafragma, facilitando a contração deste músculo e o trabalho respiratório. Objetivo Avaliar pela ultrassonografia do diafragma a excur-são diafragmática em recém-nascidos prematuros antes e após MRCSM. Métodos Ensaio clínico antes e depois avaliando por ultrassonografia do diafragma a eficácia do MRCSM na amplitude das excursões diafragmáticas. Resultados A amos-tra do estudo foi composta por 48 recém-nascidos prematuros nascidos com idade gestacional média de 33,0 ± 2,8 semanas e peso médio ao nascer de 1904,1 ± 708,9 gramas. Os recém-nascidos foram classificados em três grupos: sem síndrome do desconforto respiratório (SDR; n = 26), com SDR (n = 15) e com apneia (n = 7) como causa de internação na unidade de terapia intensiva neonatal (UTIN) . As medidas de excursão e espessamento diafragmático foram semelhantes em recém-nascidos sem ou com SDR ou apneia e houve aumento significativo na amplitude das excursões diafragmáticas após MRCSM (p < 0,001; tamanho de efeito > 0,68) e menor espes-samento diafragmático na expiração em todos eles. A fração de espessamento do diafragma foi de 0,50 (0,33 - 0,72) e a taxa de espessamento do diafragma foi de 0,04 (0,03 - 0,07). Essas medidas não apresentaram variação significativa com a presença ou ausência de SDR ou apneia (p > 0,05). Não houve variações significativas na frequência cardíaca (p = 0,30), frequência respiratória (p = 0,79), saturação periférica de oxigênio, considerando os recém-nascidos em ar ambiente (p = 0,17) em comparação com o valor basal. Conclusão O MRCSM foi eficaz, seguro e aumentou a amplitude da excursão e espessura diafragmática em recém-nascidos prematuros com uma semana de idade, independentemente da presença ou ausência de SDR ou apneia como causa de admissão na UTIN.

7.
J. bras. pneumol ; 46(4): e20180237, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1134889

RESUMO

ABSTRACT Objective: To translate the Richards-Campbell Sleep Questionnaire (RCSQ) and Sleep in the Intensive Care Unit Questionnaire (SICUQ) to Portuguese, making the appropriate cross-cultural adaptations for their use in Brazil, as well as to determine the interobserver reliability of the instruments. Methods: In this study, we evaluated medical and surgical patients admitted to the adult ICU of the Federal University of Paraná Hospital de Clínicas, in the city of Curitiba, Brazil, between June of 2017 and January of 2018. The translation and cross-cultural adaptation of the questionnaires involved the following steps: translation, synthesis, back-translation, revision by an expert panel, approval of the back-translation by the original authors, pretesting, and creation of the final versions. Two researchers applied the Portuguese-language versions in the evaluation of critically ill patients. Interobserver reliability was assessed by calculating the intraclass correlation coefficient (ICC) and 95% CI. Results: The sample comprised 50 patients, of whom 27 (54%) were women. The mean age was 47.7 ± 17.5 years. The main reason for ICU admission, in 10 patients (20%), was cancer. The interobserver reliability of the questionnaires ranged from good to excellent. For the RCSQ, the ICC was 0.84 (95% CI: 0.71-0.90). For SICUQ domains 1-5 (sleep quality and daytime sleepiness), the ICC was 0.75 (95% CI: 0.55-0.86), whereas it was 0.86 (95% CI: 0.76-0.92) for SICUQ domains 6 and 7 (causes of sleep disruption). Conclusions: The cross-culturally adapted, Portuguese-language versions of the RCSQ and SICUQ appear to have good interobserver reliability.


RESUMO Objetivo: Traduzir e adaptar transculturalmente o Richards-Campbell Sleep Questionnaire, designado Questionário de Sono Richards-Campbell (QSRC), e Sleep in the Intensive Care Unit Questionnaire, designado Questionário de Sono em UTI (QS-UTI), para a língua portuguesa do Brasil e determinar a confiabilidade interobservador dos instrumentos. Métodos: O estudo incluiu pacientes clínicos e cirúrgicos da UTI Adulto do Hospital de Clínicas da Universidade Federal do Paraná, localizado em Curitiba (PR) entre junho de 2017 e janeiro de 2018. A tradução e a adaptação transcultural seguiram as seguintes etapas: tradução, síntese das versões, tradução reversa, revisão pelo comitê de especialistas, aprovação dos autores originais, pré-teste e versão final dos questionários. As versões na língua portuguesa foram utilizadas por dois pesquisadores na avaliação dos pacientes críticos. A confiabilidade interobservador foi avaliada pelo coeficiente de correlação intraclasse (CCI) e IC95%. Resultados: A amostra foi composta por 50 pacientes, sendo a maioria mulheres (n = 27; 54%). A média de idade foi de 47,7 ± 17,5 anos. O principal motivo de internação foram doenças oncológicas (n = 10; 20%). Os questionários demonstraram de boa a alta confiabilidade interobservador. Para o QSRC, observou-se um CCI = 0,84 (IC95%: 0,71-0,90); para o QS-UTI, observou-se, para os domínios de 1 a 5, um CCI = 0,75 (IC95%: 0,55-0,86) e, para os domínios 6 e 7, um CCI = 0,86 (IC95%: 0,76-0,92). Conclusões: Os resultados de confiabilidade interobservador permitem que as versões traduzidas e adaptadas transculturalmente para o português do Brasil dos questionários QSRC e do QS-UTI sejam utilizadas como importantes ferramentas de avaliação do sono nas UTIs de adultos no Brasil.


Assuntos
Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Sono , Comparação Transcultural , Idioma , Portugal , Traduções , Brasil , Inquéritos e Questionários , Reprodutibilidade dos Testes , Unidades de Terapia Intensiva
8.
Fisioter. Mov. (Online) ; 32: e003204, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-984387

RESUMO

Abstract Introduction: Long-term home oxygen therapy (LTOT) can be successfully used in the treatment and prevention of chronic lung diseases, as it improves quality of life, increases survival, and reduces the lenght of hospital stays. However, to the authors' knowledge there are no descriptive studies with details of the clinical and social profile of patients using LTOT in the state of Paraná. Objective: To analyze the profile of LTOT users in the state of Paraná. Method: All patients registered in the LTOT program of the Curitiba Municipal Department of Health were recruited to the study. Participants answered a questionnaire with questions about their education level, family income, main diagnosis, comorbidities, hours/day of O2 use, and hospitalizations in the previous year. Results: 386 patients (67 ± 20.4 years; 66% females) were interviewed. Chronic obstructive pulmonary disease (COPD) was the most common disease (58.5%); 60.6% were former smokers and 84.5% did not practice any kind of physical activity; dyspnea was the most common symptom (81.3%) and immobility was the most commonly reported inconvenience (33%); 55.7% used O2 24 hours a day; 53.6% had been hospitalized in the previous year; 33.9% had not completed primary school; 31.4% had an income of one minimum monthly wage or less. Conclusion: LTOT users in Curitiba are primarily elderly women with COPD, with low family income and limited schooling. It is extremely important that health professionals provide educational and preventive measures for this population, to minimize the impact of COPD in the community.


Resumo Introdução: No tratamento e prevenção de doenças pulmonares crônica, o uso da Oxigenoterapia Domiciliar Prolongada (ODP) mostra-se favorável, pois melhora a qualidade de vida, aumenta sobrevida e reduz períodos de hospitalização. No entanto, os autores desconhecem estudos descritivos que relatem o perfil clínico e social dos pacientes que usam ODP no estado do Paraná. Objetivo: Analisar o perfil dos usuários do Programa de Oxigenoterapia Domiciliar Prolongada (ODP) no estado do Paraná. Método: Foram recrutados todos os indivíduos cadastrados no Programa de ODP da Secretaria Municipal de Saúde de Curitiba. Os participantes responderam a uma ficha estruturada, com questões relacionadas à escolaridade, renda familiar, diagnóstico principal, comorbidades, horas/dia de O2, internamento no último ano. Resultados: Foram entrevistados 386 pacientes (67 ± 20,4 anos; 66% gênero feminino). A Doença Pulmonar Obstrutiva Crônica (DPOC) foi a doença mais prevalente (58,5%); 60,6% eram ex-tabagistas e 84,5% não praticavam nenhum tipo de atividade física; a dispneia foi o sintoma mais comum (81,3%) e o imobilismo foi o incomodo mais relatado (33%); 55,7% faziam uso de O2 durante 24 horas; 53,6% necessitaram de internamento no último ano; 33,9% escolaridade até Ensino Fundamental Incompleto; 31,4% com renda de até 1 salário mínimo. Conclusão: Usuários de ODP em sua maioria são mulheres, idosas, com DPOC, apresentaram baixa renda familiar e baixo grau de escolaridade. É de extrema importância que os profissionais de saúde levem medidas educativas e preventivas para essa população, a fim de minimizar o impacto da DPOC na comunidade.


Resumen Introducción: En el tratamiento y prevención de enfermedades pulmonares crónicas, el uso de la Oxigenoterapia Domiciliar Prolongada (ODP) se muestra favorable, pues mejora la calidad de vida, aumenta la supervivencia y reduce períodos de hospitalización. Sin embargo, los autores desconocen estudios descriptivos que relatan el perfil clínico y social de los pacientes que usan ODP en el estado de Paraná. Objetivo: Analizar el perfil de los usuarios del ODP en el estado de Paraná. Método: Fueron reclutados todos los individuos registrados en el Programa de ODP de la Secretaría Municipal de Salud de Curitiba. Los participantes respondieron a una ficha con cuestiones relacionadas la escolaridad, ingreso familiar, diagnóstico principal, comorbilidades, horas/día O2, internamiento en el último año. Resultados: Fueron entrevistados 386 pacientes (67 ± 20,4 años; 66% femenino). La enfermedad pulmonar obstructiva crónica (EPOC) fue la enfermedad más prevalente (58,5%); 60,6% eran ex tabaqueros y el 84,5% no practicaba ningúna actividad física; la disnea fue el síntoma más común (81,3%) y el inmovilismo fue el inconveniente más reportado (33%); 55,7% hacía uso de O2 durante 24 horas; 53,6% necesitó de internamiento en el último año; 31,4% con renta de hasta 1 salario mínimo. Conclusión: Los usuarios de ODP en su mayoría son mujeres, ancianas, con EPOC, presentaron baja renta familiar y bajo grado de escolaridad. Es de extrema importancia que los profesionales de la salud lleven medidas educativas y preventivas para esa población, a fin de minimizar el impacto de la EPOC en la comunidad.


Assuntos
Oxigenoterapia , Perfil de Saúde , Pneumopatias
9.
Clinics ; 74: e930, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1039544

RESUMO

OBJECTIVES: Loss of muscle mass and/or physical performance, a condition commonly known as sarcopenia, is prevalent in chronic obstructive pulmonary disease (COPD) and is associated with adverse outcomes. The aim of this study was to investigate the association between functional performance and sarcopenia in COPD patients classified by disease severity according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) criteria. METHODS: The study was a cross-sectional observational and the sample size consisted of 35 COPD patients (69.24±1.54 years, 20 men). Physical performance was assessed with the timed up-and-go (TUG) test. Sarcopenia was assessed according to the European Working Group on Sarcopenia in Older People criteria. RESULTS: The frequency of sarcopenia was 20% and was more prevalent among individuals classified with greater disease severity, GOLD III, n=4 patients (23%) and GOLD IV, n=3 patients (27%), p=0.83. The mean time to complete the TUG test was 11.66±4.78 s. Binary logistic regression revealed an association between the TUG test and sarcopenia adjusted by disease severity (OR=1.55, 95% CI: 1.03-8.23, p=0.04). CONCLUSION: Our findings showed that worse performance in the TUG test leads to a substantial increase in the chance of COPD patients presenting sarcopenia.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Força da Mão/fisiologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Sarcopenia/fisiopatologia , Marcha/fisiologia , Índice de Gravidade de Doença , Índice de Massa Corporal , Projetos Piloto , Estudos Transversais , Circunferência da Cintura
10.
Rev. bras. cineantropom. desempenho hum ; 20(6): 566-575, Nov.-Dec. 2018. tab, ilus
Artigo em Inglês | LILACS | ID: biblio-990552

RESUMO

Abstract At birth, preterm newborns (PTNB) often require Neonatal-ICU hospitalization, which, despite being a care setting, also causes stress such as pain, sleep disturbances and wakefulness, and alterations of physiological parameters. The aim of this study was to analyze the effects of aquatic physiotherapy on pain, sleep disturbances and wakefulness, and physiological variables of PTNB in Neonatal-ICU. Pain, sleep disturbances and wakefulness, and alterations of physiological parameters were evaluated at three moments: 5 minutes before intervention, immediately after and 10 minutes after intervention. At intervention, participants were wrapped in soft fabric and immersed at shoulder level in warm water (36 ° C to 37.5 ° C). Sideways, forward, backward and rotational movements were performed. Twenty-two newborns participated in the study. The results obtained in relation to pain, sleep state and wakefulness showed significant improvements in reevaluations after intervention. Physiological variables also underwent significant changes and remained within normality parameters. The results indicate that aquatic physiotherapy is effective in reducing pain, improving sleep and wakefulness and physiological variables of PTNB in Neonatal-ICU.


Resumo Ao nascer, o recém-nascido pré-termo (RNPT) frequentemente necessita internamento em UTI-Neonatal que, apesar de ser um ambiente de cuidados, também causa estresses ao RNPT como a dor, alterações de sono e vigília e de parâmetros fisiológicos. Objetivou-se analisar os efeitos da fisioterapia aquática sobre a dor, o estado de sono e vigília e variáveis fisiológicas de RNPT internados em UTI Neonatal. Avaliações sobre dor, estado de sono e vigília e das variáveis fisiológicas foram realizadas em três momentos: 5 minutos antes da intervenção, imediatamente após e 10 minutos após. Na intervenção, os participantes foram envoltos em tecidos macios e imersos, a nível do ombro, em água aquecida (36°C a 37,5°C). Foram realizados movimentos látero-laterais, ântero-posteriores e rotacionais. Participaram 22 RNPT. Os resultados obtidos em relação à dor e ao estado de sono e vigília mostram melhoras significativas nas reavaliações após a intervenção. As variáveis fisiológicas também sofreram mudanças significativas e mantiveram-se dentro dos parâmetros de normalidade. Esta pesquisa aponta que a fisioterapia aquática é efetiva na redução da dor, melhora do estado de sono e vigília e das variáveis fisiológicas de RNPT internados em UTI-Neonatal.


Assuntos
Recém-Nascido , Recém-Nascido Prematuro , Hidroterapia , Sono/fisiologia , Vigília/fisiologia , Manejo da Dor
11.
Cad. Bras. Ter. Ocup ; 26(1): 187-206, marc. 30, 2018.
Artigo em Inglês, Português | LILACS | ID: biblio-995374

RESUMO

[{"text": "Introdução: Exercícios de alongamento são incluídos em programas de treinamento e reabilitação, no\r\nsentido de melhorar a flexibilidade de adultos e idosos. No entanto, ainda não há consenso na literatura acerca das\r\nrecomendações para prescrição do alongamento. Objetivo: O objetivo deste estudo foi apresentar uma atualização\r\ndas evidências recentes sobre a prescrição e os efeitos musculoesqueléticos dos exercícios de alongamento no\r\nadulto e idoso. Método: Foram realizadas buscas de artigos nas principais bases de dados relacionados ao tema, no\r\nperíodo de 2006 a 2017, com descritores "muscle stretching exercise"; "long-term effect"; "elderly"; "exercício de\r\nalongamento muscular", "efeitos a longo prazo" e "idoso". Resultados: Após a análise, 31 artigos foram incluídos.\r\nA literatura mostrou que a duração do alongamento deve ser entre 10s e 30s, por repetição, para o adulto jovem,\r\ne de 30s a 60s para o idoso. Com relação aos efeitos agudos, observou-se que, para adultos jovens, durações de\r\nalongamento a partir de 60s podem comprometer o desempenho de força muscular, fato que parece não ocorrer com\r\nidosos. Os principais efeitos crônicos encontrados para o adulto jovem e idoso foram o incremento da flexibilidade\r\ne amplitude de movimento, e para o idoso verificou-se também melhora do torque, equilíbrio, marcha, mobilidade\r\ne funcionalidade. A grande variabilidade metodológica dos artigos analisados dificulta o estabelecimento de um\r\nconsenso. Conclusão: Recomenda-se que o exercício de alongamento seja prescrito considerando as evidências para\r\na população específica, isto é, adulto ou idoso, bem como de acordo com o objetivo a ser atingido.", "_i": "pt"}, {"text": "Introduction: Stretching exercises have been included in training and rehabilitation programs to improve\r\nthe flexibility of adults and elderly people. However, there is no consensus in the literature about the recommendations\r\nfor stretching prescription. Objective: The aim of this study was to present an update of recent evidences about the\r\nprescription and the musculoskeletal effects of stretching exercises in adults and elderly. Method: Articles were\r\nsearched on major databases and related to the period from 2006 to 2017, with the following descriptors: "muscle\r\nstretching exercise", "long-term effect", "elderly", "exercício de alongamento muscular", "efeitos a longo prazo"\r\nand "idoso". Results: After the analysis, 31 articles were included. The literature showed that the duration of the\r\nstretching should be between 10 to 30 seconds, each repetition, for young adults, and from 30 to 60 seconds for the\r\nelderly. Regarding acute effects, it was observed that for young adults, stretching durations from 60 seconds may\r\nimpair muscle strength performance, what does not seem to occur with elderly people. The main chronic effects\r\nfound for young and elderly adults were enhancement in flexibility and range of motion, and for the elderly, it was\r\nalso observed improvement on torque, balance, gait, mobility and functionality. The wide methodological variability of the articles analyzed impairs the establishment of a consensus. Conclusion: It is recommended that the stretching\r\nexercise must be prescribed considering the evidence for the specific population, namely, adult or elderly people,\r\nas well as the goal to be achieved.", "_i": "en"}]

12.
Rev. bras. geriatr. gerontol ; 19(2): 235-246, tab, graf
Artigo em Português | LILACS | ID: lil-785197

RESUMO

Resumo Introdução: O envelhecimento impõe modificações na composição corporal dos indivíduos. Uma das características mais marcantes desse período é a perda progressiva de massa, força e função musculares, conhecida como sarcopenia. Objetivos: Verificar a presença de sarcopenia em idosas hígidas da comunidade utilizando combinações de diferentes métodos para avaliar massa muscular (MM) e desempenho físico, bem como se há concordância entre as combinações para diagnóstico da sarcopenia. Método: Estudo transversal com 37 idosas da Universidade Aberta da Maturidade. Os parâmetros para avaliar a MM foram: circunferência da panturrilha (CP) e massa muscular esquelética (MME) por meio da impedância bioelétrica (BIA) e índice de músculo esquelético (IME). Quanto à performance física, realizou-se a força de preensão palmar (FPP) com dinamômetro manual, velocidade de marcha (VM) em 10 metros e o timed up and go (TUG) para mobilidade funcional. Para comparar os métodos diagnósticos de sarcopenia foram empregadas quatro combinações distintas: C1= IME+FPP+VM; C2= IME+FPP+TUG; C3= CP+FPP+VM e C4= CP+FPP+TUG, de acordo com o proposto pelo consenso europeu. Para verificação da diferença entre os métodos foram aplicados os testes de Kruskal-Wallis e as comparações múltiplas para dados não pareados; e o coeficiente Kappa ponderado para avaliação do grau de concordância. Resultados: As combinações C1 e C2 identificaram pré-sarcopenia, sarcopenia e sarcopenia grave. Entre C1 e C2, evidenciou-se alta concordância (0,92), já C3 e C4 não identificaram presença de sarcopenia nas idosas. Conclusão: A CP, para avaliar a MM, pode não detectar a sarcopenia em idosas com excesso de peso. Porém, a alta concordância entre as duas combinações que utilizaram o IME e VM ou TUG, indicam a aplicação de ambas na prática clínica.


Abstract Introduction: Aging imposes changes in the body composition of individuals. One of the most striking changes during this period is the progressive loss of mass, strength and muscle function, known as sarcopenia. Objectives: To evaluate the presence of sarcopenia in healthy elderly women living in the community through a combination of different methods to assess muscle mass (MM) and physical performance, as well as analyzing whether there is correlation between the different methods of defining sarcopenia. Methods: A cross-sectional study was performed of 37 older adults of the Universidade Aberta da Maturidade (Open University for Mature Persons). The parameters used to assess MM were calf circumference (CC) and skeletal muscle mass (SMM) through bioelectrical impedance (BIA) and the skeletal muscle index (SMI) Handgrip strength (HS) using a manual dynamometer, gait speed (GS) over 10m and the timed up and go (TUG) test for functional mobility were used to measure physical performance. To compare the sarcopenia diagnostic methods four different combinations were employed: C1= SMI+HS+GS; C2= SMI+HS+TUG; C3= CC+HS+GS and C4= CC+HS+TUG, according to European consensus proposals. To verify the differences between the methods the Kruskal-Wallis test and Multiple Comparisons for Unpaired Data were applied, and the weighted Kappa coefficient was used to assess the degree of agreement. Results: The C1 and C2 combinations identified pre-sarcopenia, sarcopenia and severe sarcopenia. A close correlation between C1 and C2 was found (0.92), while C3 and C4 did not identify the presence of sarcopenia in the elderly women. Conclusion: CC used to evaluate MM was not precise in the detection of sarcopenia in overweight elderly women. However, there was a strong agreement between the two combinations using SMI and GS or TUG, suggesting that both can be effectively applied in clinical practice.

13.
Acta fisiátrica ; 22(4): 181-185, dez. 2015.
Artigo em Inglês, Português | LILACS | ID: biblio-969

RESUMO

Objetivo: Avaliar o desempenho funcional e o histórico de quedas de idosas. Método: Estudo observacional de corte transversal, onde foram selecionadas 57 idosas da comunidade, divididas em 3 grupos, segundo a faixa etária: G1- 60 a 69 anos; G2- 70 a 79 anos e G3- 80 a 89 anos. Foram avaliados: mobilidade funcional ("Timed Up & Go Test"); potência muscular (Teste de sentar e levantar 5 vezes); força de preensão manual (dinamômetro manual JAMAR®), histórico e prevalência de quedas. A análise das diferenças intergrupos foi realizada por meio da ANOVA One way e post hoc Tukey. As correlações foram avaliadas por meio do teste de Spearman. Resultados: Idosas do G3 quando comparadas aos grupos G1 e G2, apresentaram diminuição da FPM (18,08 ± 3,29 Kgf vs. 28,10 ± 4,26 Kgf; 18,08 ± 3,29Kgf vs. 22,92 ± 4,01, p = 0,001), da potencia muscular (14,44 ± 2,85s vs. 12,27 ± 2,34s; 14,44 ± 2,85s vs. 13,16 ± 2,27s, p = 0,04) e da mobilidade funcional (11,56 ± 3,10s vs. 8,57 ± 2,25s; 11,56 ± 3,10s vs. 10,30 ± 2,58s, p = 0,004). A maior prevalência de quedas foi nas idosas do G2 (52,6%) sendo que, nos últimos 6 meses, 26% caíram 1 vez, 5% caíram 2 vezes; 10% caíram 3 e 4 vezes. As idosas do G1 e G3 caíram 1 vez. A frequência de quedas apresentou correlação com mobilidade funcional (r = -0,52, p = 0,018). A idade apresentou correlação com a força de preensão manual (r = -0,67, p = 0,0001), potencia muscular (r = 0,31, p = 0,02) e com mobilidade funcional (r = 0,49, p = 0,0001). Conclusão: A prevalência de quedas foi maior na faixa etária entre 70-79 anos e quanto maior a idade pior o desempenho musculoesquelético e funcional


Objective: To evaluate the functional performance and the history of falls in older women. Method: Observational cross-sectional study, 57 community-dwelling elderly women were divided into 3 groups, based on their age: G1- 60 to 69 years-old; G2- 70 to 79 years-old, and G3- 80 to 89 years-old. The following were assessed: Functional mobility (Timed "Up & Go Test"); muscle power (Five Times Sit To Stand Test); handgrip strength (JAMAR® hand dynamometer), and the prior history and prevalence of falls. The analyses of differences among groups were done by the one-way ANOVA and the Tukey post hoc test. The correlations were performed using Spearman's test. Results: The women in the G3 group, when compared to G1 and G2, showed less handgrip strength (18.08 ± 3.29 Kgf vs. 28.10 ± 4.26 Kgf; 18.08 ± 3.29Kgf vs. 22.92 ± 4.01, p = 0.001); muscle power (14.44 ± 2.85s vs. 12.27 ± 2.34s; 14.44 ± 2.85s vs. 13.16 ± 2.27s, p = 0.04) and functional mobility (11.56 ± 3.10s vs. 8.57 ± 2.25s; 11.56 ± 3.10s vs. 10.30 ± 2.58s, p = 0.004). In the previous 6 months, the highest incidence of falls was in the G2 (5.6%): 26% fell once, 5% fell twice; and 10% fell 3 and 4 times. The women of G1 and G3 had fallen only once. The frequency of falls showed correlation with functional mobility (r = -0.52, p = 0.018). The age groups displayed correlation with the handgrip strength (r = -0.67, p = 0.0001); muscle power (r = 0.31, p = 0.02) and the functional mobility (r = 0.49, p = 0.0001). Conclusion: The prevalence of falls was more pronounced in the women aged between 70-79 years-old and, the older the women, the worse their muscular and functional performance


Assuntos
Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Acidentes por Quedas , Força Muscular , Estudos Transversais , Estudo Observacional
14.
J. bras. pneumol ; 39(4): 427-433, June-August/2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-686605

RESUMO

OBJECTIVE: To describe the intra-rater and inter-rater reliability of the Brazilian Portuguese version of the fatigue severity scale (FSS) in patients with COPD and to identify the presence of its association with parameters of pulmonary function, dyspnea, and functional capacity. METHODS: This was an observational cross-sectional study involving 50 patients with COPD, who completed the FSS in interviews with two researchers in two visits. The FSS scores were correlated with those of the Medical Research Council (MRC) scale, as well as with FEV1, FVC, and six-minute walk distance (6MWD). RESULTS: The mean age of the patients was 69.4 ± 8.23 years, whereas the mean FEV1 was 46.5 ± 20.4% of the predicted value. The scale was reliable, with an intraclass correlation coefficient of 0.90 (95% CI, 0.81-0.94; p < 0.01). The FSS scores showed significant correlations with those of MRC scale (r = 0.70; p < 0.01), as well as with 6MWD (r = –0.77; p < 0.01), FEV1 (r = –0.38; p < 0.01), FVC (r = –0.35; p < 0.01), and stage of the disease in accordance with the Global Initiative for Chronic Obstructive Lung Disease criteria (r = 0.37; p < 0.01). CONCLUSIONS: The Brazilian Portuguese version of the FSS proved reliable for use in COPD patients in Brazil and showed significant correlations with sensation of dyspnea, functional capacity, pulmonary function, and stage of the disease. .


OBJETIVO: Descrever a reprodutibilidade intra e interobservador da versão brasileira da escala de gravidade da fadiga (EGF) em pacientes com DPOC e verificar a presença de sua associação com parâmetros de função pulmonar, dispneia e capacidade funcional. MÉTODOS: Estudo observacional de corte transversal no qual 50 pacientes com DPOC responderam a EGF em forma de entrevista a dois pesquisadores em duas visitas. Os escores da EGF foram correlacionados aos da escala Medical Research Council (MRC), VEF1, CVF e a distância percorrida no teste da caminhada de seis minutos (DTC6). RESULTADOS: A média de idade dos pacientes foi de 69,4 ± 8,23 anos, enquanto a de VEF1 foi de 46,5 ± 20,4% do previsto. A EGF foi considerada reprodutível, com um coeficiente de correlação intraclasse de 0,90 (IC95%, 0,81-0,94; p < 0,01). Os escores da EGF mostraram correlações significantes com os da escala MRC (r = 0,70; p < 0,01), DTC6 (r = –0,77; p < 0,01), VEF1 (r = –0,38; p < 0,01), CVF (r = –0,35; p < 0,01) e a estágio da doença pela Global Initiative for Chronic Obstructive Lung Disease (r = 0,37; p < 0,01). CONCLUSÕES: A versão brasileira da EGF mostrou-se reprodutível para uso em pacientes com DPOC no Brasil e apresentou correlações significantes com a sensação de dispneia, capacidade funcional, ...


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dispneia/fisiopatologia , Fadiga/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Brasil , Estudos Transversais , Dispneia/etiologia , Teste de Esforço , Tolerância ao Exercício , Fadiga/etiologia , Idioma , Variações Dependentes do Observador , Doença Pulmonar Obstrutiva Crônica/complicações , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Inquéritos e Questionários
15.
Rev. latinoam. enferm ; 20(4): 753-760, JulyAug. 2012. ilus, tab
Artigo em Inglês | LILACS, BDENF | ID: lil-649723

RESUMO

This study aimed to evaluate the effect of microcurrent electrical stimulation on pain and area of venous ulcers. In a pilot study for a single-blind controlled clinical trial, carried out at an outpatient clinic during four weeks, 14 subjects with venous ulcers (mean age 62±9 years) were divided in two groups: microcurrent (n=8) and control group (n=6). Pain (by Visual Analogue Scale) and the ulcer area were measured by planimetry. There was a significant difference between the two groups with respect to pain (microcurrent group from 8.5 (6.5-9.75) to 3.5 (1-4.75) and control group from 7.5 (5.75-10) to 8.5 (5.5-10), p<0.01). Non-significant changes were found with respect to ulcer area (planimetry by graph paper, p=0.41 and by Image J®, p=0.41). In conclusion, the application of microcurrent improves the pain of patients with venous ulcers (ClinicalTrials.gov: NCT01372020).


O objetivo neste estudo foi avaliar o efeito da estimulação elétrica, por microcorrente, sobre a dor e a área de superfície de úlceras venosas. Em estudo-piloto para um ensaio clínico controlado simples-cego, realizado em uma clínica durante 4 semanas, dividiram-se 14 indivíduos (62±9 anos de idade) em dois grupos: grupo microcorrente (n=8) e grupo-controle (n=6). Avaliaram-se a dor (por meio da Escala Visual Analógica) e a área de superfície da úlcera por meio da Planimetria. Houve diferença significativa entre os dois grupos em relação à dor (grupo de microcorrente de 8,5 (6,5-9,75) para 3,5 (1-4,75) e grupo-controle de 7,5 (5,75-10) para 8,5 (5,5-10), p<0,01)). Não se verificou diferença significativa relacionada à área de superfície da úlcera (Planimetria com papel vegetal, p=0,41 e pelo software Image J®, p=0,41). Conclui-se que a aplicação de microcorrente melhora o quadro álgico de indivíduos com úlceras venosas. Registro ClinicalTrials.gov: NCT01372020.


Este estudio objetivó evaluar el efecto de la estimulación eléctrica por microcorriente sobre el dolor y el área de superficie de úlceras venosas. En un estudio piloto para un ensayo clínico controlado simple ciego, realizado en una clínica durante 4 semanas, se dividieron 14 individuos (62±9 años de edad) en dos grupos: grupo microcorriente (n=8) y grupo control (n=6). Se evaluaron el dolor (por medio de la Escala Visual Analógica) y el área de superficie de la úlcera por medio de la Planimetría. Hubo diferencia significativa entre los dos grupos con relación al dolor (grupo de microcorriente de 8,5 (6,5-9,75) para 3,5 (1-4,75) y grupo control de 7,5 (5,75-10) para 8,5 (5,5-10), p<0,01)). No se verificó una diferencia significativa relacionada al área de superficie de la úlcera (Planimetría con papel vegetal, p=0,41 y por el software Image J®, p=0,41). Se concluye que la aplicación de microcorriente mejora el cuadro álgico de individuos con úlceras venosas. Registro ClinicalTrials.gov: NCT01372020.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Analgesia/métodos , Terapia por Estimulação Elétrica , Manejo da Dor/métodos , Dor/etiologia , Úlcera Varicosa/complicações , Terapia por Estimulação Elétrica/métodos , Projetos Piloto , Método Simples-Cego
16.
Arq. neuropsiquiatr ; 70(7): 497-500, July 2012. graf, tab
Artigo em Inglês | LILACS | ID: lil-642973

RESUMO

The Fatigue Severity Scale (FSS) is one of the most frequently used self-rating scales for fatigue in Parkinson's disease (PD) and it lacks a validated Brazilian-Portuguese version. OBJECTIVE: To determine the construct validity and reproducibility of a Brazilian-Portuguese version of the FSS in patients with PD. METHODS: In a cross-sectional study, a Portuguese-language version of the FSS was applied to 30 patients with PD (62±11 years-old). The Parkinson's disease questionnaire (PDQ-39) was used as the validation criterion, while the Hoehn and Yahr scale, the Unified Parkinson's Disease Rating Scale (UPDRS), and the Beck Depression Inventory were employed to analyze the correlations with the FSS score. RESULTS: The test-retest intraclass correlation coefficient was 0.91 (p<0.01) for the Brazilian-Portuguese version of the FSS score, which was highly correlated with the PDQ-39 overall score (r=0.93; p<0.01) and the Beck Depression Inventory (r=0.75; p<0.01). It showed a correlation with the Hoehn and Yahr scale (r=0.40; p=0.02), and with the UPDRS as well (r=0.45, p=0.01). CONCLUSIONS: The Brazilian-Portuguese version of the FSS is valid and reproducible for using in Brazilian patients with PD.


A Fatigue Severity Scale (FSS-BR) é uma das mais usadas para avaliação da fadiga na doença de Parkinson e até hoje não foi validada para o português no Brasil. OBJETIVO: Determinar a validade de construto e a reprodutibilidade da versão brasileira da (FSS-BR) em pacientes com doença de Parkinson. MÉTODOS: Em um estudo de corte transversal, a versão brasileira da Fatigue Severity Scale foi aplicada em 30 pacientes com doença de Parkinson (62±11 anos). O questionário de qualidade de vida da doença de Parkinson (PDQ-39) foi utilizado como critério de validação, assim como a escala Hoehn e Yahr (HY), a Escala de Graduação Unificada da Doença de Parkinson (UPDRS) e o Inventário de Depressão de Beck (BDI) foram empregados para analisar as correlações com a FSS-BR. RESULTADOS: O coeficiente de correlação intraclasse foi 0,91 (p<0,01) para a versão brasileira do escore da FSS, que foi muito correlacionado com o escore total do PDQ-39 (r=0,93; p<0,01) e com o BDI (r=0,75; p<0,01); demonstrou também correlação com a escala de gravidade HY (r=0,40; p=0,02), e com a escala UPDRS (r=0,45, p=0,01). CONCLUSÕES: A FSS-BR mostrou-se válida e reprodutível para uso em pacientes brasileiros com doença de Parkinson.


Assuntos
Feminino , Humanos , Pessoa de Meia-Idade , Fadiga/diagnóstico , Doença de Parkinson/complicações , Inquéritos e Questionários , Brasil , Estudos Transversais , Características Culturais , Fadiga/etiologia , Idioma , Qualidade de Vida , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Tradução
18.
Fisioter. Bras ; 6(6): 424-428, nov.-dez. 2005.
Artigo em Português | LILACS | ID: lil-491191

RESUMO

Objetivo: O objetivo desse estudo foi analisar a alteração do índice diafragmático em pacientes que foram submetidos à cirurgia de Fobi-Capella pela via laparoscópica. Materiais e Métodos: Os dados foram obtidos através da análise das medidas do pré e pósoperatório através da cirtometria. Foram avaliados 25 pacientes no pré e pós-operatório, obtendo-se as medidas do Índice Diafragmático (ID) através da cirtometria destas mesmas fases. Este índice é capaz de refletir o movimento tóraco-abdominal, determinado pelas mudanças nas dimensões ântero-posteriores da caixa torácica (CT) e do abdome (AB) e foi calculado utilizando-se a seguinte formula: ID = ∆ AB/∆ AB+∆ CT. Os dados foram obtidos através da análise das medidas do pré e pós-operatório. Resultados: Observou-se uma diferença significativa entre as médias do índice diafragmático na fase pré-operatória de 0,54 e de 0,41 na fase pos – operatória (T = 0,0; Z = 4,37; p = 0,000012), provando a diminuição do ID nos 2 primeiros dias pós-cirúrgicos. Conclusão: Segundo esse estudo, todos os pacientes apresentaram alteração do Índice Diafragmático, que diminuiu 13% no primeiro dia de pós-operatório, permanecendo inalterado no 2º dia de pósoperatório. É visível a diminuição da expansibilidade tóracoabdominal no período pós-operatório.


Purpose: The aim of this study was to evaluate the diaphragmatic index alterations in patients undergone to Fobi- Capella surgery, comparing values of pre-operative and postoperative. Materials and Methods: The observation includes 25 patients evaluated in pre-operative and post-operative, finding values of diaphragmatic index. This index reflects the movement between thorax and abdomen. Changes dimensions of thoracic box and abdomen obtained this movement. It was calculated across formula: ID = ∆ AB/∆ AB+∆ CT. Results: The medium diaphragmatic index in the preoperative was of 0,54 and the postoperative was of 0,41. The difference gain was of 0,13. Conclusion: Was observed alterations in thoracic and abdominal expansibility in postoperative of all the patients and an important difference between diaphragmatic index of preoperative and post-operative. The statistics significance was 5% (p < 0,05).


Assuntos
Anastomose em-Y de Roux , Cirurgia Bariátrica , Derivação Gástrica , Obesidade Mórbida , Complicações Pós-Operatórias
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA