Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. mex. ing. bioméd ; 40(1): e201803EE1, Jan.-Apr. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1043135

RESUMO

Abstract One of the most used bacteria in the Quorum Sensing (QS) experimental works is the Vibrio harveyi, which is used as reporter bacteria to detect the Autoinducers-2 (AI-2) activity of other bacteria. Nevertheless, the description of its QS mechanism by the mathematical modeling is an approach still unexploited. For biological systems, it is necessary to consider the high variability of the experimental data, thus identifiability and parametric reliability analyses must be performed before a model could be used. The following work describes a methodology for parameter fitting and parametric identifiability analysis in a model that describes the dynamics of AI-2 in V. harveyi bacteria. Identifiability analyses showed that all parameters are identifiable, but parametric dependency analyses showed two linearly dependent parameters. According to our results, the model is adequate to describe the AI-2 dynamics in V. harveyi.


Resumen Una de las bacterias más utilizadas en los trabajos experimentales de detección de quorum (QS) es la Vibrio harveyi, que se utiliza como bacteria reportera para detectar la actividad de Autoinductores-2 (AI-2) de otras bacterias. Sin embargo, la descripción de su mecanismo de QS por medio del modelado matemático es un enfoque aún no explotado. En el caso de los sistemas biológicos, es necesario considerar la alta variabilidad de los datos experimentales, por lo que deben realizarse análisis de identificabilidad y fiabilidad paramétrica antes de que un modelo pueda ser usado. El siguiente trabajo describe una metodología para el ajuste de parámetros y el análisis de la identificabilidad paramétrica en un modelo que describe la dinámica de la AI-2 en las bacterias V. harveyi. Los análisis de identificabilidad mostraron que todos los parámetros son identificables, pero los análisis de dependencia paramétrica mostraron dos parámetros linealmente dependientes. De acuerdo con los resultados, el modelo es adecuado para describir la dinámica AI-2 en V. harveyi.

2.
Arq. bras. med. vet. zootec ; 66(2): 471-480, Jan.-Apr. 2014. tab
Artigo em Inglês | LILACS | ID: lil-709287

RESUMO

The aim of this study was to investigate the presence of arsenic, lead and cadmium residues in samples of liver, kidney and muscle of poultry and swine during the years from 2002 to 2008. A total of 1978 samples were analyzed: 1031 of poultry and 947 of swine from Brazilian slaughterhouses. The samples were analyzed at the National Agricultural Laboratory using the atomic absorption spectrometry technique. In poultry, the arsenic residues were detected in 53.6% of liver samples, although no results have exceeded the MRL. In kidneys, 39.7% of the samples showed measurable residues and there was no violation of the limits. Regarding lead, there were 5 contaminated liver samples and 24 contaminated kidney samples (1.5 and 3.6% respectively). In muscle tissue there was only one sample with residues...


Objetivou-se investigar a presença de resíduos de arsênico, chumbo e cádmio em amostras de fígado, rins e músculo de aves e suínos, durante os anos de 2002 a 2008. Um total de 1.978 amostras foi analisado: 1031 de aves e 947 de suínos provenientes de matadouros brasileiros. As amostras foram analisadas no Laboratório Nacional Agropecuário (Lanagro), sendo utilizada a técnica de espectrometria de absorção atômica. Em aves, os resíduos de arsênico foram detectados em 53,6% das amostras de fígado, embora sem exceder o LMR. Nos rins, 39,7% das amostras mostraram resíduos mensuráveis e não houve violação dos limites. Em relação ao chumbo, cinco amostras de fígado e 24 de amostras de rins estavam contaminadas (1,5 e 3,6%, respectivamente). No tecido muscular, houve apenas uma amostra com resíduos. Para o cádmio, 3,8% das amostras apresentavam valores abaixo do LMR. Resíduos de cádmio foram encontrados em 110 amostras de rins (16,3% testados), mas apenas uma ultrapassou o limite máximo permitido pela legislação nacional. Em suínos, resíduos de arsênico foram detectados em 15,3% das amostras de fígado, sem exceder o LMR. Nos rins, 14,2% das amostras apresentaram resíduos mensuráveis...


Assuntos
Animais , Arsênio/isolamento & purificação , Aves/metabolismo , Cádmio/isolamento & purificação , Chumbo/isolamento & purificação , Fígado , Rim , Suínos/metabolismo , Limites Permissíveis de Riscos Ocupacionais/análise , Concentração Máxima Permitida , Metais Pesados/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA