1.
Indian J Ophthalmol ; 2013 Nov ; 61 (11): 626-629
Artigo em Inglês | IMSEAR | ID: sea-155442

RESUMO

Purpose: To assess the visual outcome and rotational stability of single‑piece open loop toric Intra Ocular Lens (IOL) in a clinical setting. Materials and Methods: In a prospective study, 122 eyes of 77 patients were followed up for a period of 12 months after cataract surgery with toric open loop IOL implantation. The pre‑operative markings for the position of incision and IOL placement were done under slit lamp by anterior stromal puncture. The visual acuity, refraction, and IOL position were assessed at day 1, 1 week, 1 month, 3 months, 6 months, and 12 months after surgery. Results: The mean age of the cohort was 56 yrs (S.D. 13.88; range 16 to 87 years). The mean pre‑operative cylinder of corneal astigmatism was 1.37 D. (SD 0.79, range 1.0 to 5.87 D). Mean post‑operative refractive cylinder was 0.36 D (SD 0.57, range 0 to 1.50 D) at 12 months. Ninety‑seven percent of the eyes were within 1 D of residual astigmatism. Ninety‑four percent of patients had uncorrected visual acuity of 20/30 or better. Four eyes required IOL repositioning due to rotation. At 12 months, 96.7% of the IOLs were within 10 degrees of the target axis. There was no rotation seen after 6 months. Conclusion: Toric IOLs are very effective and consistent in correcting astigmatism during the cataract surgery. IOL rotation happens mostly within a month of surgery, and if significant, requires early repositioning.

2.
Indian J Ophthalmol ; 2010 May; 58(3): 219-222
Artigo em Inglês | IMSEAR | ID: sea-136058

RESUMO

Purpose: To compare horizontal corneal diameter measurements using the Orbscan Eyemetrics function and Orbscan corneal topographer. Materials and Methods: Seventy-three eyes of 37 patients were included in the study. In all cases, the automated white-to-white (WTW) measurements were obtained using Orbscan by two observers. Using the Eyemetrics function, the WTW was measured manually by the same observers from limbus to limbus using the digital caliper passing through the five point corneal reflections on the Orbscan real image. The data was analyzed using SPSS software for correlation, reliability and inter-rater repeatability. Results: The mean horizontal corneal diameter was 11.74 ± 0.32mm (SD) with the Orbscan and 11.92 ± 0.33mm (SD) with Eyemetrics Software-based measurement. A good positive correlation (Spearman r = 0.720, P = 0.026) was found between these two measurements. The coefficient of inter-rater repeatability was 0.89 for the Orbscan and 0.94 for the Eyemetrics software measurements on the anterior segment images. The Bland and Altman analysis showed large limits of agreement between Orbscan WTW and Eyemetrics WTW measurements. The intra-session repeatability scores for repeat measurements for the Orbscan WTW and Eyemetrics measurements were good. Conclusion: Eyemetrics can be used to measure WTW and the Eyemetrics measured WTW was longer than the WTW measured by Orbscan.


Assuntos
Topografia da Córnea/instrumentação , Topografia da Córnea/métodos , Feminino , Humanos , Masculino
3.
Indian J Ophthalmol ; 2008 Jul-Aug; 56(4): 307-12
Artigo em Inglês | IMSEAR | ID: sea-71512

RESUMO

AIM: To study the effect of treatment on vision-related quality of life (VR-QOL) in uveitis patients. MATERIALS AND METHODS: Interviewer-administered questionnaire-based evaluation of visual function and VR-QOL in Tamil-speaking adult patients with active uveitis at presentation and follow-up by the same interviewer. RESULTS: Ninety-eight patients participated in this study. There was a statistically significant improvement in VR-QOL in all the scales following treatment ( P < 0.001). Patients with chronic uveitis showed better improvement upon treatment than patients with acute uveitis. The visual symptoms scale showed moderate gains following treatment (effect size 0.56). Persons with bilateral disease had poorer mean scores compared to those with unilateral disease. Visual acuity was closely correlated with VR-QOL scores. CONCLUSION: The VR-QOL measurement has shown that it is sensitive to demonstrate the problems of patients with uveitis irrespective of their demographic profile. The scores improved significantly in patients with uveitis following treatment and have shown close correlation to visual acuity thus demonstrating that VR-QOL is effective in assessing the response to treatment.


Assuntos
Doença Aguda , Adolescente , Adulto , Idoso , Antibacterianos/uso terapêutico , Doença Crônica , Feminino , Glucocorticoides/uso terapêutico , Humanos , Imunossupressores/uso terapêutico , Índia , Idioma , Masculino , Pessoa de Meia-Idade , Soluções Oftálmicas/uso terapêutico , Estudos Prospectivos , Qualidade de Vida , Inquéritos e Questionários , Perfil de Impacto da Doença , Uveíte/tratamento farmacológico , Acuidade Visual/fisiologia