1.
CoDAS ; 26(2): 105-111, Mar-Apr/2014. tab
Artigo em Inglês | LILACS | ID: lil-711133

RESUMO

PURPOSE: To investigate the existence of correlations between the performance of children in auditory temporal tests (Frequency Pattern and Gaps in Noise - GIN) and IQ, attention, memory and age measurements. METHOD: Fifteen typically developing individuals between the ages of 7 to 12 years and normal hearing participated in the study. Auditory temporal processing tests (GIN and Frequency Pattern), as well as a Memory test (Digit Span), Attention tests (auditory and visual modality) and intelligence tests (RAVEN test of Progressive Matrices) were applied. RESULTS: Significant and positive correlation between the Frequency Pattern test and age variable were found, which was considered good (p<0.01, 75.6%). There were no significant correlations between the GIN test and the variables tested. CONCLUSIONS: Auditory temporal skills seem to be influenced by different factors: while the performance in temporal ordering skill seems to be influenced by maturational processes, the performance in temporal resolution was not influenced by any of the aspects investigated. .


OBJETIVO: Investigar a existência de correlações entre o desempenho de crianças com desenvolvimento típico em testes temporais auditivos (Padrão de Frequência e Gaps in Noise - GIN) e medidas de memória, atenção, quociente intelectual e a idade. MÉTODO: Quinze participantes, com idades entre 7 e 12 anos, sem queixas envolvendo audição e desenvolvimento cognitivo, foram submetidos aos testes de processamento temporal auditivo (GIN e Padrão de Frequência), teste de Memória (Span de Dígitos), Atenção (auditiva e visual) e testes de inteligência (Matrizes Progressivas de Raven). RESULTADOS: Foram encontradas correlações significantes e positivas entre o teste Padrão de Frequência e a variável idade, sendo essa considerada boa (p<0,01, 75,6%). Não foram verificadas correlações significantes entre o teste GIN e as variáveis testadas. CONCLUSÃO: As habilidades temporais consideradas parecem ser influenciadas por diferentes fatores: enquanto a habilidade de ordenação temporal parece ser influenciada por processos maturacionais, o desempenho para a habilidade de resolução temporal não foi influenciado por nenhum dos aspectos investigados. .


Assuntos
Criança , Feminino , Humanos , Masculino , Atenção/fisiologia , Inteligência/fisiologia , Memória/fisiologia , Percepção da Fala/fisiologia , Estimulação Acústica/métodos , Testes Auditivos/métodos
2.
Rev. bras. oftalmol ; 72(6): 388-395, nov.-dez. 2013. tab
Artigo em Português | LILACS | ID: lil-704741

RESUMO

OBJETIVO: Elaborar e validar o questionário de qualidade de vida na versão do idioma português. MÉTODOS: O questionário "Cataract TyPESpecification" modificado foi desenvolvido especificamente para avaliar a qualidade de vida pós-cirurgia de catarata. O questionário avaliou 10 itens status funcionais por meio de 18 perguntas. Foi aplicado por um único examinador, com o objetivo de graduar a satisfação visual de 0 a 10 (0 muito insatisfeito; 5 neutro; 10 muito satisfeito). Houve estudo prospectivo comparativo, não randomizado, que incluiu 142 olhos de 71 pacientes com catarata da Universidade de São Paulo. A avaliação oftalmológica contou com medida da acuidade visual para longa, intermediária e curta distâncias, sem correção e com a melhor correção óptica e questionário de satisfação. Foi submetido a um questionário de satisfação quanto à acuidade visual e fenômenos fóticos. Todos os exames foram realizados com 6 meses de pós-operatório. RESULTADOS: A média de idade dos pacientes foi de 60,7 ± 6,6 anos no grupo Tecnis, 63,1 ± 4,4 anos no grupo Restor e 63,7 ± 4,2 anos no grupo SN60AT/SN60WF. A acuidade visual para perto não-corrigida e a corrigida para longe foram estatisticamente superiores nos grupos Restor® e Tecnis® comparadas ao grupo SN60AT/SN60WF (p<0,001). Não houve diferença estatística entre os grupos quando comparadas a acuidade visual para longe não-corrigida e a melhor corrigida (p=0,56). O questionário de satisfação apresentou maior independência de óculos a favor da Tecnis® (9,3/10) e Restor® (8,7/10), mas com mais queixas de halos (Restor® 18,8%; Tecnis® 21,7%) e glare (Restor® 25%; Tecnis® 26,1%) do que no grupo SN60AT/SN60WF. CONCLUSÃO: A Restor® e Tecnis® apresentaram melhor acuidade visual para perto do que o grupo SN60AT/SN60WF. As lentes Restor® e Tecnis® apresentaram maior satisfação na visão de perto e independência do uso de óculos e fenômenos fóticos do que as lentes monofocais...


PURPOSE: Development and validation of quality of life questionnaire in pseudophakic patients in Portuguese. METHODS: The modified Cataract TyPESpecification questionnaire was specifically developed to assess quality of life after cataract surgery, functional status evaluated with 10 items and contains 18 questions. All questions were applied by a single examiner, with the goal of graduating visual satisfaction from 0 to 10 (0 means very dissatisfied, 5 neutral, 10 very satisfied).This prospective comparative study included 142 eyes of 71 patients in Sao Paulo University. The ophthalmologic evaluation performed included near, intermediate and distance corrected and uncorrected visual acuity and quality of life questionaire. The minimum follow-up was 6 months. RESULTS: The mean age of patients was 60.7± 6.6 years in theTecnis®MF, 63.1 ±4.4 years in-groupRestor®63.7±4.2 years in-group SN60AT/SN60WF. Uncorrected and distance-corrected near visual acuity were statistically higher in theRestor® and Tecnis® groups compared to the SN60AT/SN60WF group (p<0.001). There were no statistical differences between groups comparing uncorrected and best-corrected distance visual acuity (p=0.56). Satisfaction questionnaire showed high glasses independence fortheTecnis®MF (9.3 /10) and Restor® (8.7 /10), but with more unsatisfied of halos (18.8% Restor®, Tecnis®21, 7%) and glare (Restor® 25%;Tecnis®26.1%) than the group SN60AT/SN60WF. CONCLUSION: Cataract patients who received multifocal (Restor®; Tecnis®MF) IOLs at time of surgery obtained better uncorrected and distance corrected near visual acuity and reported better overall vision, less limitation in visual function, less spectacle dependency, and more glare or halo than those who received monofocal (SN60AT; SN60WF) IOLs. Cataract TyPESpecification questionnaire was a strong predictor of change in patient satisfaction caused by cataract surgery.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Extração de Catarata , Implante de Lente Intraocular , Satisfação do Paciente , Qualidade de Vida , Acuidade Visual , Estudos Prospectivos , Inquéritos e Questionários
3.
Int. j. odontostomatol. (Print) ; 4(1): 87-92, abr. 2010. graf
Artigo em Inglês | LILACS | ID: lil-596809

RESUMO

Electrophysiological retinal alterations were evaluated in a group of odontologists contaminated with mercury vapor. The group consisted of 20 odontologists exposed to mercury vapor during the professional activities. The multifocal electroretinogram showed significant statistical differences for the values of the amplitudes of Ni and P1 in all of the rings: ring 1 (p=0.002) for amplitude Ni and (p < 0.00i) for amplitude P1; ring 2(p < O.001) for amplitudes Ni and P1; ring 3(p < O.00i) for amplitude Ni and (p=0.002) for amplitude Pi; ring 4 (p < 0.00i) for amplitudes Ni and Pi; ring 5 (p < 0.001)for amplitude Ni and (p=0.001 ) for amplitude P1; ring 6 (p < 0.001 ) for amplitudes Ni and P1. Increases of the latency P1 for ring1 (p=0.013), ring 5 (p=0.038) and ring 6 (p=0.038) were also found. We conclude that mercurial contamination causes important alterations in cone and rod photoreceptors and also in bipolar cells.


Fueron evaluadas alteraciones electrofisiológicas de la retina en un grupo de odontólogos contaminados con el vapor de mercurio. El grupo estaba formado por 20 odontologos expuestos al vapor de mercurio durante la actividad profesional. El electrorretinograma multifocal señalo diferencias estadísticas significativas para los valores de amplitud N1 y P1 en todos los anillos: anillo 1 (p=0,002) para la amplitud N1 y (p<0,001) para la amplitud P1; anillo 2 (p<0,001) para las amplitudes N1 y P1; anillo 3 (p<0,001) para la amplitud N1 y ( p=0,002) para la amplitud P1; anillo 4 (p<0,001) para la amplitud N1 y P1; anillo 5 (p<0,001) para la amplitud N1 y (p=0,001) para la amplitud P1; anillo 6 (p<0,001) para las amplitudes N1 y P1. El aumento de la latencia P1 para el anillo 1 (p=0,013), el anillo 5 (p=0,038) y el anillo 6 (p=0, 038) también fueron encontrados. Se concluye que la contaminación por mercurio causa importantes alteraciones en los conos y bastoncillos, fotorreceptores y también en las células bipolares.


Assuntos
Humanos , Odontólogos , Gases/efeitos adversos , Mercúrio/efeitos adversos , Retina , Retina/fisiopatologia , Eletrofisiologia , Exposição Ocupacional