Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Arq. bras. cardiol ; 118(5): 861-872, maio 2022. graf, ilus, tab
Artigo em Inglês, Português | LILACS, CONASS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1374358

RESUMO

BACKGROUND: Hypertrophic cardiomyopathy (HCM) can cause obstruction in the left ventricular outflow tract (LVOT), and be responsible for the onset of limiting symptoms, such as tiredness. When such symptoms are refractory to pharmacological treatment, interventionist alternative therapies can be useful, such as septal ablation through the infusion of alcohol in the coronary artery or through myectomy. Recently, the use of a radiofrequency (RF) catheter for endocardial septal ablation guided by electroanatomic mapping has proven to be efficient, despite the high incidence of complete atrioventricular block. An alternative would be the application of RF at the beginning point of the septal gradient guided by the transesophageal echocardiography (TEE). The echocardiography is an imaging method with high accuracy to determine septal anatomy. OBJECTIVE: To assess the long term effect of septal ablation for the relief of ventricular-arterial gradient, using TEE to help place the catheter in the area of larger septal obstruction. Besides, to assess the effects of ablation on the functional class and echocardiographic parameters. METHODS: Twelve asymptomatic patients, with LVOT obstruction, refractory to pharmacological therapy, underwent endocardial septal ablation with 8mm-tip catheters, whose placement was oriented in the region of larger obstruction, assisted by the TEE. Temperature-controlled and staggered RF applications were performed. After each application, the gradient was reassessed and a new application was performed according to the clinical criterion. The effects of RF applications were assessed both for the gradient at rest and for that provoked by the Valsalva maneuver, and considering the gradient. The differences were significant when p-value was lower than or equal to 0.05. RESULTS: It was possible to observe that the mean reduction of the maximum gradients was from 96.8±34.7 mmHg to 62.7±25.4 mmHg three months after the procedure (p=0.0036). After one year, the mean of maximum gradient was 36.1±23.8 mmHg (p=0.0001). The procedure was well tolerated, without records of complete atrioventricular block nor severe complications. CONCLUSION: The TEE-guided septal ablation was efficient and safe, and the results were maintained during the clinical follow-up period. It is a reasonable option for the interventionist treatment of LVOT obstruction in HCM.


FUNDAMENTOS: A cardiomiopatia hipertrófica (CMH) pode causar obstrução da via de saída do ventrículo esquerdo (VSVE) e ser responsável pelo surgimento de sintomas limitantes, como cansaço físico. Quando tais sintomas são refratários ao tratamento farmacológico, os tratamentos alternativos intervencionistas podem ser úteis, como a ablação septal por meio da infusão de álcool na artéria coronária ou por meio da miectomia cirúrgica. Recentemente, o uso de cateter de radiofrequência (RF) para ablação do septo endocárdico guiado por mapeamento eletroanatômico mostrou-se eficaz apesar da elevada incidência de bloqueio atrioventricular total. Uma alternativa seria a aplicação de radiofrequência no ponto de início do gradiente septal guiada pelo ecocardiograma transesofágico (ETE). O ecocardiograma é um método de imagem com elevada acurácia para determinação da anatomia septal. OBJETIVO: Avaliar o efeito em longo prazo da ablação septal para alívio do gradiente ventrículo-arterial, utilizando o ETE para auxiliar no posicionamento do cateter na área de maior obstrução septal. Avaliar também os efeitos da ablação na classe funcional e parâmetros ecocardiográficos. MÉTODOS: Doze pacientes sintomáticos com obstrução da VSVE, refratários à terapia farmacológica, foram submetidos à ablação endocárdica septal com cateteres com ponta de 8 mm, cujo posicionamento foi orientado na região de maior obstrução com auxílio do ETE. Foram realizadas aplicações de radiofrequência (RF) termocontrolada e escalonadas sobre a área alvo. Após cada aplicação, o gradiente era reavaliado e nova aplicação era realizada de acordo com critério clínico. Foram avaliados os efeitos das aplicações de RF tanto para o gradiente em repouso como para o provocado por meio da manobra de Valsalva, e considerado o gradiente. As diferenças foram significativas quando o valor de p foi menor ou igual a 0,05. RESULTADOS: Observou-se que a redução da média dos gradientes máximos obtidos foi de 96,8±34,7 mmHg para 62,7±25,4 mmHg ao final de três meses do procedimento (p=0,0036). Após um ano, a média dos gradientes máximos obtidos foi de 36,1±23,8 mmHg (p=0,0001). O procedimento foi bem tolerado e não houve registro de bloqueio atrioventricular total e nem complicações graves. CONCLUSÃO: A ablação septal guiada pelo ETE foi eficaz e segura, com resultados mantidos durante o período de seguimento clínico. É uma opção razoável para o tratamento intervencionista da obstrução da VSVE em CMH.


Assuntos
Cardiomiopatia Hipertrófica
2.
Rev. bras. anestesiol ; 68(6): 549-557, Nov.-Dec. 2018. tab, graf
Artigo em Inglês | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-977399

RESUMO

Abstract Background: After advancement of cardiovascular surgery, there is also exponential development of anesthetic techniques in this field. Patients with increasing clinical complexity challenge cardiac anesthesiologists to keep constantly updated. An evaluation of Brazilian's cardiovascular anesthesia fellowship at Dante Pazzanese Institute of Cardiology has been made and information has been collected to evaluate the fellowship program in cardiovascular anesthesia. Method: Target participants were made up of former fellowships, contacted via e-mail containing an invitation to voluntarily participate. Explanation of the survey's purpose was provided. This communication was signed by the authors and contained a hyperlink to the survey, which was constructed on and hosted on a web platform. The survey was composed of 10 objectives questions designed to describe training and subsequent career. Results: The adjusted survey response rate was 71%. Two-thirds of respondents agreed that fellowship training provided them an advantage in the job market and 93% of respondents currently work with cardiac anesthesia. At least 87% of participants would recommend the course to other anesthesiologists. Conclusion: Fellowship graduates judge their technical training as excellent and incorporated the knowledge acquired in their daily practice. However, there are improvements to be made. We believe this document may be useful as a reference for other institutions to develop their own cardiovascular anesthesia fellowship programs.


Resumo Justificativa: Com o avanço da cirurgia cardiovascular nos últimos anos, houve também um desenvolvimento exponencial das técnicas anestésicas. Pacientes com complexidade clínica crescente desafiam os anestesiologistas cardíacos a se manterem constantemente atualizados. Uma avaliação do programa de aprimoramento em anestesia cardiovascular brasileira do Instituto Dante Pazzanese de Cardiologia foi feita e informações foram coletadas para avaliar o programa. Método: Os participantes-alvo eram formados por ex-aprimorandos, contatados via e-mail com um convite para participação voluntária. A explicação do objetivo da pesquisa foi fornecida. Essa comunicação foi assinada pelos autores e continha um link para a pesquisa, que foi construída e hospedada em uma plataforma web. A pesquisa foi composta por 10 questões objetivas destinadas a descrever o treinamento e a carreira subsequente. Resultados: A taxa de resposta ajustada para a pesquisa foi de 71%. Dois terços dos entrevistados concordaram que o treinamento do programa lhes proporcionou uma vantagem no mercado de trabalho e 93% dos entrevistados trabalham atualmente com anestesia cardíaca. Pelo menos 87% dos participantes recomendariam o curso a outros anestesiologistas. Conclusão: Os graduados do programa de aprimoramento julgam sua formação técnica como excelente e incorporaram os conhecimentos adquiridos em sua prática diária. No entanto, há melhorias a serem feitas. Acreditamos que este documento possa ser útil como referência para outras instituições desenvolverem seus próprios programas de aprimoramento em anestesia cardiovascular.


Assuntos
Educação de Pós-Graduação em Medicina , Bolsas de Estudo , Anestesia em Procedimentos Cardíacos , Anestesiologia/educação , Brasil , Atitude do Pessoal de Saúde , Autorrelato
3.
Rev. bras. anestesiol ; 68(5): 437-441, Sept.-Oct. 2018. tab, graf
Artigo em Inglês | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-958339

RESUMO

Abstract Background and objectives Aortic stenosis is the most common type of heart valve disease. Percutaneous aortic valve replacement has become the alternative for patients considered at high risk for surgery. Controlled mechanical ventilation with tracheal intubation has been the choice for this type of procedure, however the use of noninvasive ventilation in cardiac patients has shown to be beneficial. Janus is a novel full-face mask that allows application of noninvasive ventilation support during anesthesia. Our main objective was to evaluate the feasibility of transcatheter aortic valve replacement with prolonged transesophageal echocardiographic monitoring under deep inhalational sedation delivered through a new mask for noninvasive ventilation. Methods A case series observational study that included five patients with critical aortic stenosis that underwent inhalational anesthesia with sevoflurane for transcatheter aortic valve replacement in a hybrid room of a teaching hospital. Standard monitors and bispectral index were used, followed by inhalational induction and placement of the Janus mask. Anesthesia was maintained with sevoflurane. Patients were transferred to intensive care unit after the procedure. Complications related to the mask use, transesofageal echocardiography accessibility and respiratory implications to the patients were recorded. Results All procedures were uneventful and no major complications were observed intraoperatively. One patient presented CO2 retention (50 mmHg) and sevoflurane leak around the central opening of the mask, both without clinical significance. Conclusions The use of inhalational anesthesia with the facial mask Janus is a safe and efficient alternative to general anesthesia with tracheal intubation for transcatheter aortic valve replacement and can easily accommodate the use of transesophageal echocardiography intraoperatively.


Resumo Justificativa e objetivos A estenose aórtica é o tipo mais comum de doença valvular cardíaca. A substituição percutânea de válvula aórtica tornou-se a alternativa para pacientes cirúrgicos considerados de alto risco. A ventilação mecânica controlada com intubação traqueal tem sido a escolha para esse tipo de procedimento; porém, o uso de ventilação não invasiva em pacientes cardíacos mostrou ser benéfico. Janus é uma nova máscara facial que permite a aplicação de suporte à VNI durante a anestesia. Nosso objetivo primário foi avaliar a viabilidade da substituição transcateter de valva aórtica com monitoração ecocardiográfica transesofágica prolongada sob sedação inalatória profunda através de uma nova máscara para ventilação não invasiva. Métodos Estudo observacional de série de casos que incluiu cinco pacientes com estenose aórtica em fase crítica, submetidos à anestesia inalatória com sevoflurano para substituição transcateter de valva aórtica em uma sala híbrida de um hospital universitário. Monitores padrão e índice bispectral foram usados, seguidos de indução inalatória e colocação da máscara Janus. A anestesia foi mantida com sevoflurano. Os pacientes foram transferidos para a unidade de terapia intensiva após o procedimento. As complicações relacionadas ao uso da máscara, a acessibilidade da ecocardiografia transesofágica e as implicações respiratórias para os pacientes foram registradas. Resultados Todos os procedimentos transcorreram sem incidentes e não foram observadas complicações maiores no intraoperatório. Um paciente apresentou retenção de CO2 (50 mmHg) e vazamento de sevoflurano em torno da abertura central da máscara, ambos sem significância clínica. Conclusões O uso de anestesia inalatória com a máscara facial Janus é uma opção segura e eficiente à anestesia geral com intubação traqueal para substituição transcateter de valva aórtica e pode facilmente acomodar o uso de ecocardiografia transesofágica no intraoperatório.


Assuntos
Humanos , Estenose da Valva Aórtica/cirurgia , Ecocardiografia Transesofagiana/métodos , Substituição da Valva Aórtica Transcateter/instrumentação , Intubação Intratraqueal/métodos , Adjuvantes Anestésicos
4.
Rev. Soc. Bras. Clín. Méd ; 11(3)jul.-set. 2013.
Artigo em Português | LILACS | ID: lil-686969

RESUMO

JUSTIFICATIVA E OBJETIVOS: Os estudos que avaliaram a prevalência de doença celíaca e intolerância à lactose em portadores de doença inflamatória intestinal são escassos e produziram resultados conflitantes. O reconhecimento da associação dessas doenças possui relevância clínica, já que os seus sintomas são semelhantes,dificultando o manuseio clínico desses pacientes. O objetivo deste estudo foi estimar a prevalência de má absorção de lactose e de positividade para marcadores sorológicos de doença celíaca em portadores de doença inflamatória intestinal. MÉTODOS: Estudo observacional transversal que incluiu pacientes adultos portadores de doença inflamatória intestinal em acompanhamento entre abril e dezembro de 2011. Os resultados dos exames foram extraídos dos prontuários médicos. Os pacientes foram comparados quanto ao tipo de doença inflamatória intestinal e quanto à presença deteste de tolerância oral à lactose alterado. RESULTADOS: Foram incluídos 54 pacientes, sendo 56% do sexo feminino, com média de idade de 34,6 ± 13,4 anos. Quanto ao diagnóstico, observou-se retocolite ulcerativa em 30 pacientes e doença de Crohn em 24 pacientes.Nenhum dos pacientes pesquisados apresentou marcadores sorológicos para doença celíaca (antiendomísio e/ou antitransglutaminase). Teste de tolerância oral à lactose alterado foi notado em metade dos pacientes e foi associado a menor idade ao diagnóstico.CONCLUSÃO: Neste estudo, nenhum indivíduo apresentou positividade para marcador sorológico de doença celíaca. A prevalência de má absorção de lactose foi semelhante ao descrito para a população geral, não havendo uma relação entre teste de tolerância oral à lactose alterado e variáveis especificamente relacionadas às doenças inflamatórias intestinais. Esse achado sugere que a má absorção de lactose nesse grupo se deva mais à deficiência primária de lactase do que às alterações patológicas do trato digestivo.


BACKGROUND AND OBJECTIVES: Studies evaluating the prevalence of celiac disease and lactose intolerance in patients with inflammatory bowel diseases are scarce and have produced conflicting results. The recognition of the association of these diseases has clinical relevance because its symptoms are similar and may hamper the clinical management of these patients. The objective of this study was to estimate the prevalence of lactose malabsorption and positivity for serological markers of celiac disease in inflammatory bowel diseases patients. METHODS: A cross-sectional observational study that included adult patients with inflammatory bowel diseases followed up between April and December, 2011. The laboratory results were extracted from medical records. Patients were compared according to the type of inflammatory bowel diseases and the presence of lactose malabsorption in the oral lactose tolerance test. RESULTS: Fifty-four subjects were included, 56% females, mean age 34.6 ± 13.4 years. Regarding the inflammatory bowel diseases diagnosis, ulcerative colitis was observed in 30 patients and Crohn's disease in 24 individuals. None of the included subjects presented with positive serological markers for celiac disease (anti-endomysial and/or anti-transglutaminase antibodies). Evidences of lactose malabsorption were observed in 50% of the sample and were associated with lower mean age at inflammatory bowel diseases diagnosis. CONCLUSION: In this study, none of the included subjects exhibited serological evidence of celiac disease. The prevalence of lactose malabsorption was similar to that described for the general population, and it was not related to variables specifically related to inflammatory bowel diseases. These findings suggest that the lactose malabsorption in these individuals is most likely related to primary lactase deficiency than secondary to pathological changes of the digestive tract.


Assuntos
Humanos , Masculino , Feminino , Adulto , Doença Celíaca , Doenças Inflamatórias Intestinais/diagnóstico , Intolerância à Lactose , Biomarcadores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA