Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Anesthesiology ; (12): 601-603, 2015.
Artigo em Chinês | WPRIM | ID: wpr-476410

RESUMO

Objective To evaluate the accuracy of continuous noninvasive hemoglobin ( Hb ) monitoring in the patients undergoing cesarean section. Methods A total of 200 patients, at 36-42 weeks of gestation, aged 19-40 yr, with body mass index of 20.5-35.1 kg∕m2 , of ASA physical statusⅠorⅡ, undergoing elective cesarean section from June 2014 to October 2014 in our hospital, were enrolled. A sensor was positioned at patient′s finger and connected to the Masimo Radical?7 Pulse CO?Oximeter, a continuous noninvasive Hb measurement device. Noninvasive Hb obtained with Pulse CO?oximeter ( SpHb) was recorded. Before skin incision ( T0 ) , after delivery of the placenta ( T1 ) , after suturing the uterus ( T2 ) and at the end of operation ( T3 ) , blood samples from the radical artery were collected for determination of total Hb ( tHb) , and SpHb was also recorded. The agreement between two methods was assessed using Bland?Altman analysis. Results At T0-T3, tHb was 111±9, 103±8, 94±8 and (89±7) g∕L, respectively, and SpHb was 124 ± 9, 120 ± 12, 108 ± 9 and ( 103 ± 8 ) g∕L, respectively. Bland?Altman analysis showed that at T0-T3 , the mean difference between SpHb and tHb was 13.5, 17.1, 14.1 and 13.9 g∕L, respectively, and 95% confidence interval was 13.1-13.9, 16.5-17.7, 13.6-14.6 and 13.4-14.4 g∕L, respectively. The limit of agreement was 8.4-18.6, 9.1-25.1, 7.8-20.4 and 7.4-20.4 g∕L at T0-T3 , respectively, and the interchangeable limits of the two methods ranged between 3.5-23.5, 7.1-27.1, 4.1-24.1 and 3.9-23.9 g∕L at T0-T3 , respectively. The repeatability coefficient of tHb and SpHb was 16.5 and 15.8 g∕L, respectively. The relative error of SpHb was (4.6±1.0)%, (5.3±1.4)%, (4.9±1.2)% and (4.8±1.2)% at T0-T3, respectively. Conclusion Continuous noninvasive Hb monitoring provides good accuracy in the patients undergoing cesarean section.

2.
The Journal of Clinical Anesthesiology ; (12): 1205-1207, 2015.
Artigo em Chinês | WPRIM | ID: wpr-485089

RESUMO

Objective The main objective of this study is to explore the effect of liver function on the awake BIS value.Methods According to the Child-Pugh classification,65 patients were divid-ed into three groups.Group A (n=27):patients with normal liver function;group B (n=21):pa-tients with Child-Pugh A;group C (n=1 7):patients with Child-Pugh B-C.The awake BIS value at rest was measured.Results Total bilirubin (TBIL),direct bilirubin (DBIL),indirect bilirubin (IBIL),alanine aminotransferase (ALT),aspartate aminotransferase (AST),albumin (ALB)of group B and C were significantly poorer than group A (P <0.05 or P <0.01).The coagulation func-tion of group C was poorer than group A and B (P <0.01).Compared with group A (96.2 ± 1.7) and group B (95.6±0.8),the awake BIS value of group C (94.1±3.0)was significantly reduced (P<0.01).The awake BIS value was negatively correlated with the TBIL value (r = - 0.26,P =0.039).Conclusion The awake BIS value in end-stage liver disease patients was significantly lower than that in patients with normal liver function and mild liver dysfunction.The awake BIS value may be related with the amount of total bilirubin in the blood.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA