Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Chinese Circulation Journal ; (12): 79-82, 2018.
Artigo em Chinês | WPRIM | ID: wpr-703820

RESUMO

Objective: To investigate the safety and efficacy of pulmonary vein deployment technique for percutaneous closure of atrial septal defects (ASD) solely under echocardiography guidance. Methods: A total of 38 ASD patients received pulmonary vein deployment in our hospital from 2012-10 to 2016-09 since the conventional method could not deliver the occluder to correct place. The patients were with the mean age at (16.0±15.6) years, body weight at (37.2±22.9) kg and ASD diameter at (17.1±4.2) mm. Operative effect was assessed by echocardiography. Follow-up study was conducted at 1, 3, 6, 12 months post-operation and at each year thereafter. Results: 37 patients were successfully finished pulmonary vein deployment for percutaneous closure of ASD solely under echocardiography guidance. One patient was successfully treated by a controlled steerable sheath. The mean operative time was (25.2±5.1) min and mean diameter of ASD occluder was (22.9±5.6) mm. 2 patients had trivial residual shunt at the early post-operative stage. No peripheral vascular injury, pulmonary vein and cardiac perforation occurred. All 38 patients were recovered and discharged. The average in-hospital time was (2.9±0.7) days. The patients were followed-up for (23.9±15.4) months, without complications of residual shunt, pericardial effusion, aortic regurgitation and pulmonary vein stenosis. Conclusion: Pulmonary vein deployment technique for percutaneous closure of ASD solely under echocardiography guidance was safe and effective; it can avoid radiation damage and provided a simple and practical method for ASD patients who failed to conventional method under echocardiography guidance.

2.
Chinese Circulation Journal ; (12): 1080-1084, 2018.
Artigo em Chinês | WPRIM | ID: wpr-703929

RESUMO

Objectives: The present first-in-human study aimed to assess the feasibility of percutaneous balloon mitral valvuloplasty (PBMV) for the treatment of isolated mitral stenosis (MS) under echocardiography guidance only. Methods: Data were obtained from 24 consecutive patients with severe MS, who underwent PBMV from October 2016 to October 2017 under the guidance of echocardiography only. Outpatient follow-up including chest radiography, electrocardiography, and transthoracic echocardiography was conducted at 1, 3, 6 and 12 months post procedure. Results: PBMV was successful in all 24 patients under echocardiography guidance without radiation and contrast agent. Mitral transvalvular pressure gradient derived invasive catheterization measurement dropped from(15.0±5.1) mmHg to (6.7±2.9) mmHg (P<0.01). Mitral valve area increased from (0.8±0.1) cm2at pre-PBMV to (1.7±0.1) cm2post-PBMV (P<0.01). Mean balloon diameter was (26.7±1.2) mm. Mild mitral regurgitation developed in 8 patients. Mean follow-up duration was (7.4±3.1) months. At the last follow-up, mitral valve area remained high (1.6±0.1) cm2and mean transmitral pressure gradient remained low (9.0±4.3) mmHg. No pericardial effusion or peripheral vascular complications occurred. Conclusions: In this patient cohort, PBMV could be successfully performed with echocardiography as the single imaging guidance modality, this procedure is safe and effective and avoids the radiation exposure and contrast agent use.

3.
Zhongguo Zhong Yao Za Zhi ; (24): 3969-3973, 2014.
Artigo em Chinês | WPRIM | ID: wpr-310956

RESUMO

Sixteen compounds including daphnoretin (1), isofraxidin (2), scopoletin (3), kaempferol (4), quercetin (5), guaijaverin (6), astragalin (7), quercetin-3-O-β-D-glucopyranoside (8), naringenin-7-O-β-D-glucopyranoside (9), 5-O-methylapi- genin-7-O-β-D-glucopyranoside (10), methyl gallate (11), prionitiside A (12), (2S)-2,3-dihydroxypropyl-1,6,8-trihydroxy-3- methyl-9,10- dioxoanthracene-2-carboxylate (13), 3,3'-di-O-methyl ellagic acid (14), 3'-O-methyl-3,4-O,O-metheneellagic acid-4'-O-β-D- glucopyranoside (15) and 3,4-methylenedioxy-3'-O-methylellagic acid (16), were isolated from the 70% acetone extract of Euphorbia dracunculoides Lam. Among them, compounds 1-3, 6-9, 11, and 14 were isolated from E. dracunculoides for the first time, and compounds 10, 12, 13, 15, and 16 were firstly obtained from the genus Euphorbia. Their structures were elucidated by spectroscopic analysis, including 1H-NMR, 13C-NMR, and ESI-MS.


Assuntos
Medicamentos de Ervas Chinesas , Química , Euphorbia , Química , Estrutura Molecular , Folhas de Planta , Química , Caules de Planta , Química , Espectrometria de Massas por Ionização por Electrospray
4.
Zhonghua xinxueguanbing zazhi ; (12): 744-746, 2013.
Artigo em Chinês | WPRIM | ID: wpr-261476

RESUMO

<p><b>OBJECTIVE</b>To assess the safety and effectiveness of percutaneous transcatheter closure of atrial septal defect (ASD) under transesophageal echocardiography (TEE) guidance in children.</p><p><b>METHODS</b>The study included 20 cases of patients with ASD. The patients were (4.2 ± 1.2) years old and the mean body weights were (18.2 ± 4.2) kg. The diameter of ASD before closure was (13.4 ± 3.3) mm . All procedures were guided under TEE. Procedure success was evaluated by TEE immediately after procedure.</p><p><b>RESULTS</b>Closure devices were successfully implanted in all 20 patients under TEE guidance. The diameter of closure devices was 14-26 mm. There were no procedure related complications. The ventilation time was (2.9 ± 0.8)h and the hospitalization time was (3.2 ± 0.7) days.</p><p><b>CONCLUSION</b>TEE guided percutaneous transcatheter closure is safe and effective for patients with ASD and avoids the radiation damages.</p>


Assuntos
Criança , Pré-Escolar , Feminino , Humanos , Masculino , Cateterismo , Métodos , Ecocardiografia Transesofagiana , Métodos , Comunicação Interatrial , Terapêutica
5.
Zhonghua xinxueguanbing zazhi ; (12): 681-683, 2012.
Artigo em Chinês | WPRIM | ID: wpr-326443

RESUMO

<p><b>OBJECTIVE</b>To observe the efficacy of hybrid balloon valvuloplasty for the treatment of low-body weight infants with severe congenital valvular aortic stenosis (AS).</p><p><b>METHODS</b>Five infants with severe congenital valvular aortic stenosis underwent the hybrid balloon aortic valvuloplasty through median sternotomy in the hybrid operating room. The mean age was (40.2 ± 7.0) days, weight was (4.48 ± 0.75) kg. The patients were followed up by echocardiography for 9 - 13 months post procedure.</p><p><b>RESULTS</b>Operation was successful in all 5 patients and they were discharged from hospital uneventfully. The gradient pressure decreased significantly from (98.8 ± 9.0) mm Hg (1 mm Hg = 0.133 kPa) to (13.8 ± 3.3) mm Hg (P < 0.05) post operation. There was no moderate or severe aortic insufficiency. All patients were alive, the gradient pressures was (18.8 ± 2.5) mm Hg and there was no moderate or severe aortic insufficiency during follow-up [9 - 13 (11.0 ± 1.4) months].</p><p><b>CONCLUSION</b>The hybrid balloon aortic valvuloplasty is an effective option for the low-body weight infants with severe congenital valvular aortic stenosis.</p>


Assuntos
Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estenose da Valva Aórtica , Cirurgia Geral , Valvuloplastia com Balão , Recém-Nascido de Baixo Peso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA